{"id":"https://openalex.org/W2029060594","doi":"https://doi.org/10.1109/eurocon.2011.5929285","title":"Sensor-based fixed-point DSP control of a 8/6 Switched Reluctance Motor","display_name":"Sensor-based fixed-point DSP control of a 8/6 Switched Reluctance Motor","publication_year":2011,"publication_date":"2011-04-01","ids":{"openalex":"https://openalex.org/W2029060594","doi":"https://doi.org/10.1109/eurocon.2011.5929285","mag":"2029060594"},"language":"en","primary_location":{"id":"doi:10.1109/eurocon.2011.5929285","is_oa":false,"landing_page_url":"https://doi.org/10.1109/eurocon.2011.5929285","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 IEEE EUROCON - International Conference on Computer as a Tool","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5053054456","display_name":"Ciprian \u0218or\u00e2ndaru","orcid":"https://orcid.org/0000-0002-4178-0467"},"institutions":[{"id":"https://openalex.org/I3122695212","display_name":"Polytechnic University of Timi\u015foara","ror":"https://ror.org/02v91gy68","country_code":"RO","type":"education","lineage":["https://openalex.org/I3122695212"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"C. Sorandaru","raw_affiliation_strings":["Faculty of Electrical and Power Engineering, Polytechnic University of Timisoara, Romania","\u201cPolitehnica\u201d University of Timisoara, Faculty of Electrical and Power Engineering, ROMANIA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Faculty of Electrical and Power Engineering, Polytechnic University of Timisoara, Romania","institution_ids":["https://openalex.org/I3122695212"]},{"raw_affiliation_string":"\u201cPolitehnica\u201d University of Timisoara, Faculty of Electrical and Power Engineering, ROMANIA","institution_ids":["https://openalex.org/I3122695212"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5057703580","display_name":"Sorin Mu\u015furoi","orcid":null},"institutions":[{"id":"https://openalex.org/I3122695212","display_name":"Polytechnic University of Timi\u015foara","ror":"https://ror.org/02v91gy68","country_code":"RO","type":"education","lineage":["https://openalex.org/I3122695212"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"S. Musuroi","raw_affiliation_strings":["Faculty of Electrical and Power Engineering, Polytechnic University of Timisoara, Romania","\u201cPolitehnica\u201d University of Timisoara, Faculty of Electrical and Power Engineering, ROMANIA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Faculty of Electrical and Power Engineering, Polytechnic University of Timisoara, Romania","institution_ids":["https://openalex.org/I3122695212"]},{"raw_affiliation_string":"\u201cPolitehnica\u201d University of Timisoara, Faculty of Electrical and Power Engineering, ROMANIA","institution_ids":["https://openalex.org/I3122695212"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5109171675","display_name":"M. Svoboda","orcid":null},"institutions":[{"id":"https://openalex.org/I3122695212","display_name":"Polytechnic University of Timi\u015foara","ror":"https://ror.org/02v91gy68","country_code":"RO","type":"education","lineage":["https://openalex.org/I3122695212"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"M. Svoboda","raw_affiliation_strings":["Faculty of Electrical and Power Engineering, Polytechnic University of Timisoara, Romania","\u201cPolitehnica\u201d University of Timisoara, Faculty of Electrical and Power Engineering, ROMANIA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Faculty of Electrical and Power Engineering, Polytechnic University of Timisoara, Romania","institution_ids":["https://openalex.org/I3122695212"]},{"raw_affiliation_string":"\u201cPolitehnica\u201d University of Timisoara, Faculty of Electrical and Power Engineering, ROMANIA","institution_ids":["https://openalex.org/I3122695212"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5006297800","display_name":"Thomaq Koblara","orcid":null},"institutions":[{"id":"https://openalex.org/I193184871","display_name":"Polytechnic University of Tirana","ror":"https://ror.org/05aec4025","country_code":"AL","type":"education","lineage":["https://openalex.org/I193184871"]}],"countries":["AL"],"is_corresponding":false,"raw_author_name":"T. Koblara","raw_affiliation_strings":["Faculty of Electrical Engineering, Polytechnic University of Tirana, Tirana, Albania","Polytechnic University of Tirana, Faculty of Electrical, Engineering, Tirana, Albania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Faculty of Electrical Engineering, Polytechnic University of Tirana, Tirana, Albania","institution_ids":["https://openalex.org/I193184871"]},{"raw_affiliation_string":"Polytechnic University of Tirana, Faculty of Electrical, Engineering, Tirana, Albania","institution_ids":["https://openalex.org/I193184871"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5079473063","display_name":"Nicola-Valeriu Olarescu","orcid":null},"institutions":[{"id":"https://openalex.org/I4210087926","display_name":"Diehl (Germany)","ror":"https://ror.org/003c3rr61","country_code":"DE","type":"company","lineage":["https://openalex.org/I4210087926"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Nicola-Valeriu Olarescu","raw_affiliation_strings":["Department of Electrical Drives, Diehl AKO Stiftung and Company KG, Wangen, Germany","Diehl AKO Stiftung&Co. KG/Department of Electrical, Drives, 88239, Wangen, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Drives, Diehl AKO Stiftung and Company KG, Wangen, Germany","institution_ids":["https://openalex.org/I4210087926"]},{"raw_affiliation_string":"Diehl AKO Stiftung&Co. KG/Department of Electrical, Drives, 88239, Wangen, Germany","institution_ids":["https://openalex.org/I4210087926"]}]}],"institutions":[],"countries_distinct_count":3,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.895,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.69193351,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"2","issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12169","display_name":"Non-Destructive Testing Techniques","score":0.9854999780654907,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.9793000221252441,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/switched-reluctance-motor","display_name":"Switched reluctance motor","score":0.793756365776062},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.765184760093689},{"id":"https://openalex.org/keywords/pulse-width-modulation","display_name":"Pulse-width modulation","score":0.6306411623954773},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.6037399768829346},{"id":"https://openalex.org/keywords/duty-cycle","display_name":"Duty cycle","score":0.5782434940338135},{"id":"https://openalex.org/keywords/current","display_name":"Current (fluid)","score":0.5388960242271423},{"id":"https://openalex.org/keywords/current-sensor","display_name":"Current sensor","score":0.5339317321777344},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.45442628860473633},{"id":"https://openalex.org/keywords/transistor","display_name":"Transistor","score":0.4527003765106201},{"id":"https://openalex.org/keywords/digital-signal-processing","display_name":"Digital signal processing","score":0.4455735981464386},{"id":"https://openalex.org/keywords/phase","display_name":"Phase (matter)","score":0.44048571586608887},{"id":"https://openalex.org/keywords/three-phase","display_name":"Three-phase","score":0.41970232129096985},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3762499690055847},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.3321411609649658},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3171500861644745},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.27694714069366455},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.2571747303009033},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.20290616154670715},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.1954989731311798}],"concepts":[{"id":"https://openalex.org/C12090584","wikidata":"https://www.wikidata.org/wiki/Q4107232","display_name":"Switched reluctance motor","level":3,"score":0.793756365776062},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.765184760093689},{"id":"https://openalex.org/C92746544","wikidata":"https://www.wikidata.org/wiki/Q585184","display_name":"Pulse-width modulation","level":3,"score":0.6306411623954773},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.6037399768829346},{"id":"https://openalex.org/C199822604","wikidata":"https://www.wikidata.org/wiki/Q557120","display_name":"Duty cycle","level":3,"score":0.5782434940338135},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.5388960242271423},{"id":"https://openalex.org/C55000061","wikidata":"https://www.wikidata.org/wiki/Q24894777","display_name":"Current sensor","level":3,"score":0.5339317321777344},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.45442628860473633},{"id":"https://openalex.org/C172385210","wikidata":"https://www.wikidata.org/wiki/Q5339","display_name":"Transistor","level":3,"score":0.4527003765106201},{"id":"https://openalex.org/C84462506","wikidata":"https://www.wikidata.org/wiki/Q173142","display_name":"Digital signal processing","level":2,"score":0.4455735981464386},{"id":"https://openalex.org/C44280652","wikidata":"https://www.wikidata.org/wiki/Q104837","display_name":"Phase (matter)","level":2,"score":0.44048571586608887},{"id":"https://openalex.org/C173871940","wikidata":"https://www.wikidata.org/wiki/Q471846","display_name":"Three-phase","level":3,"score":0.41970232129096985},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3762499690055847},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3321411609649658},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3171500861644745},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.27694714069366455},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2571747303009033},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.20290616154670715},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1954989731311798},{"id":"https://openalex.org/C17281054","wikidata":"https://www.wikidata.org/wiki/Q193466","display_name":"Rotor (electric)","level":2,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/eurocon.2011.5929285","is_oa":false,"landing_page_url":"https://doi.org/10.1109/eurocon.2011.5929285","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 IEEE EUROCON - International Conference on Computer as a Tool","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8899999856948853,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W1488456559","https://openalex.org/W1582489346","https://openalex.org/W2036271264","https://openalex.org/W2495487728","https://openalex.org/W2564945000","https://openalex.org/W6629160902"],"related_works":["https://openalex.org/W3174584923","https://openalex.org/W2371248658","https://openalex.org/W2957344201","https://openalex.org/W2781252968","https://openalex.org/W3005045357","https://openalex.org/W2744318269","https://openalex.org/W2513796356","https://openalex.org/W2362004083","https://openalex.org/W2903109486","https://openalex.org/W2557428230"],"abstract_inverted_index":{"This":[0],"paper":[1],"deals":[2],"with":[3,29,72],"a":[4,9,15,26,44,70,73,77],"current":[5,35,49,64],"control":[6,65],"method":[7],"of":[8,46,57],"8/6":[10],"Switched":[11],"Reluctance":[12],"Motor":[13],"using":[14,38,69],"DSP":[16],"TMS320C24\u00d7.":[17],"The":[18,34,48,63],"power":[19],"converter":[20],"used":[21,85,96],"in":[22],"the":[23,54,58,88,99],"experiments":[24],"was":[25],"classic":[27],"one,":[28],"two":[30,39,55],"transistors":[31,56],"per":[32],"phase.":[33],"is":[36,50,67],"sensed":[37],"sensor":[40],"resistances,":[41],"one":[42],"for":[43],"pair":[45],"phases.":[47],"measured":[51],"only":[52],"if":[53],"same":[59],"phase":[60,89],"are":[61],"on.":[62],"loop":[66],"performed":[68],"PWM":[71],"fixed":[74],"frequency":[75],"and":[76],"variable":[78],"duty-ratio.":[79],"A":[80,91],"proportional":[81],"controller":[82,93],"has":[83,94],"been":[84,95],"to":[86,97],"regulate":[87,98],"current.":[90],"PI":[92],"motor":[100],"speed.":[101]},"counts_by_year":[{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":1}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
