{"id":"https://openalex.org/W4403448020","doi":"https://doi.org/10.1109/etfa61755.2024.10710735","title":"Energy Efficiency Optimization and Preventive Maintenance of HVAC Systems Using Machine Learning","display_name":"Energy Efficiency Optimization and Preventive Maintenance of HVAC Systems Using Machine Learning","publication_year":2024,"publication_date":"2024-09-10","ids":{"openalex":"https://openalex.org/W4403448020","doi":"https://doi.org/10.1109/etfa61755.2024.10710735"},"language":"en","primary_location":{"id":"doi:10.1109/etfa61755.2024.10710735","is_oa":false,"landing_page_url":"https://doi.org/10.1109/etfa61755.2024.10710735","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 IEEE 29th International Conference on Emerging Technologies and Factory Automation (ETFA)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5111434706","display_name":"Aleksey Bratukhin","orcid":null},"institutions":[{"id":"https://openalex.org/I132976966","display_name":"Universit\u00e4t f\u00fcr Weiterbildung Krems","ror":"https://ror.org/03ef4a036","country_code":"AT","type":"education","lineage":["https://openalex.org/I132976966"]}],"countries":["AT"],"is_corresponding":false,"raw_author_name":"Aleksey Bratukhin","raw_affiliation_strings":["University for Continuing Education Krems,Department for Integrated Sensor Systems,Neustadt,Austria,2700"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University for Continuing Education Krems,Department for Integrated Sensor Systems,Neustadt,Austria,2700","institution_ids":["https://openalex.org/I132976966"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5034063271","display_name":"Christian Stippel","orcid":"https://orcid.org/0000-0003-0482-902X"},"institutions":[{"id":"https://openalex.org/I145847075","display_name":"TU Wien","ror":"https://ror.org/04d836q62","country_code":"AT","type":"education","lineage":["https://openalex.org/I145847075"]}],"countries":["AT"],"is_corresponding":false,"raw_author_name":"Christian Stippel","raw_affiliation_strings":["Institute of Computer Technology, TU Wien,Vienna,Austria,1040"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Computer Technology, TU Wien,Vienna,Austria,1040","institution_ids":["https://openalex.org/I145847075"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5004288654","display_name":"David Sengl","orcid":null},"institutions":[{"id":"https://openalex.org/I121760703","display_name":"University of Applied Sciences Technikum Wien","ror":"https://ror.org/04jsx0x49","country_code":"AT","type":"education","lineage":["https://openalex.org/I121760703"]}],"countries":["AT"],"is_corresponding":false,"raw_author_name":"David Sengl","raw_affiliation_strings":["FH Technikum Wien,Department Industrial Engineering,Vienna,Austria,1200"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"FH Technikum Wien,Department Industrial Engineering,Vienna,Austria,1200","institution_ids":["https://openalex.org/I121760703"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5077227223","display_name":"Markus D. Kobelrausch","orcid":null},"institutions":[{"id":"https://openalex.org/I145847075","display_name":"TU Wien","ror":"https://ror.org/04d836q62","country_code":"AT","type":"education","lineage":["https://openalex.org/I145847075"]}],"countries":["AT"],"is_corresponding":false,"raw_author_name":"Markus Kobelrausch","raw_affiliation_strings":["Institute of Computer Technology, TU Wien,Vienna,Austria,1040"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Computer Technology, TU Wien,Vienna,Austria,1040","institution_ids":["https://openalex.org/I145847075"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5090568831","display_name":"Thilo Sauter","orcid":"https://orcid.org/0000-0003-1559-8394"},"institutions":[{"id":"https://openalex.org/I132976966","display_name":"Universit\u00e4t f\u00fcr Weiterbildung Krems","ror":"https://ror.org/03ef4a036","country_code":"AT","type":"education","lineage":["https://openalex.org/I132976966"]}],"countries":["AT"],"is_corresponding":false,"raw_author_name":"Thilo Sauter","raw_affiliation_strings":["University for Continuing Education Krems,Department for Integrated Sensor Systems,Neustadt,Austria,2700"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University for Continuing Education Krems,Department for Integrated Sensor Systems,Neustadt,Austria,2700","institution_ids":["https://openalex.org/I132976966"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.7529000043869019,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.7529000043869019,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.8490184545516968},{"id":"https://openalex.org/keywords/preventive-maintenance","display_name":"Preventive maintenance","score":0.7897999286651611},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6378934383392334},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.5912962555885315},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.42698997259140015},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3896515369415283},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.3353072702884674},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2734675407409668},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.21956995129585266},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.20295816659927368},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.1373072862625122},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.05721136927604675}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.8490184545516968},{"id":"https://openalex.org/C24090081","wikidata":"https://www.wikidata.org/wiki/Q1043452","display_name":"Preventive maintenance","level":2,"score":0.7897999286651611},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6378934383392334},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.5912962555885315},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.42698997259140015},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3896515369415283},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3353072702884674},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2734675407409668},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.21956995129585266},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.20295816659927368},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.1373072862625122},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.05721136927604675},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/etfa61755.2024.10710735","is_oa":false,"landing_page_url":"https://doi.org/10.1109/etfa61755.2024.10710735","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 IEEE 29th International Conference on Emerging Technologies and Factory Automation (ETFA)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8899999856948853,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W4200059648","https://openalex.org/W4223562347","https://openalex.org/W4292939437","https://openalex.org/W4387025761","https://openalex.org/W4401880338"],"related_works":["https://openalex.org/W4214827973","https://openalex.org/W2315243270","https://openalex.org/W4231557335","https://openalex.org/W2394158014","https://openalex.org/W2370623581","https://openalex.org/W2065422689","https://openalex.org/W2130432129","https://openalex.org/W2552440346","https://openalex.org/W2890184129","https://openalex.org/W1978071414"],"abstract_inverted_index":{"HVAC":[0,28],"systems":[1],"are":[2,49],"characterized":[3],"by":[4],"rigid":[5],"and":[6,30,41,55],"complex":[7],"internal":[8],"behaviour":[9],"that":[10,70],"limits":[11],"the":[12,66],"options":[13],"for":[14,37,44,60],"efficiency":[15],"optimization.":[16],"KI4HVACs":[17],"project":[18],"aims":[19],"to":[20,24],"apply":[21],"machine":[22],"learning":[23,34,43],"improve":[25],"office":[26,74],"building":[27,75],"operation":[29],"maintenance":[31],"efficiency.":[32],"Reinforcement":[33],"is":[35],"used":[36],"energy":[38],"use":[39],"optimization":[40],"supervised":[42],"preventive":[45,61],"maintenance.":[46,62],"The":[47,63],"models":[48],"wrapped":[50],"into":[51],"an":[52,72],"MPC":[53],"based":[54],"a":[56],"decision":[57],"tree":[58],"algorithm":[59],"system":[64],"uses":[65],"TRNSYS18":[67],"simulation":[68],"environment":[69],"matches":[71],"actual":[73],"with":[76],"multiple":[77],"zones.":[78]},"counts_by_year":[{"year":2025,"cited_by_count":2}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
