{"id":"https://openalex.org/W2156256666","doi":"https://doi.org/10.1109/etfa.2009.5347044","title":"Formal verification of UML-modeled machine controls","display_name":"Formal verification of UML-modeled machine controls","publication_year":2009,"publication_date":"2009-09-01","ids":{"openalex":"https://openalex.org/W2156256666","doi":"https://doi.org/10.1109/etfa.2009.5347044","mag":"2156256666"},"language":"en","primary_location":{"id":"doi:10.1109/etfa.2009.5347044","is_oa":false,"landing_page_url":"https://doi.org/10.1109/etfa.2009.5347044","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2009 IEEE Conference on Emerging Technologies &amp; Factory Automation","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5021841828","display_name":"Thomas Klotz","orcid":"https://orcid.org/0000-0002-0503-9815"},"institutions":[{"id":"https://openalex.org/I4210124274","display_name":"Fraunhofer Institute for Integrated Circuits","ror":"https://ror.org/024ape423","country_code":"DE","type":"facility","lineage":["https://openalex.org/I4210124274","https://openalex.org/I4923324"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Thomas Klotz","raw_affiliation_strings":["Fraunhofer Institute for Integrated Circuits, Design Automation Division, Zeunerstr. 38, 01069 Dresden, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Fraunhofer Institute for Integrated Circuits, Design Automation Division, Zeunerstr. 38, 01069 Dresden, Germany","institution_ids":["https://openalex.org/I4210124274"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5087112184","display_name":"Eva Fordran","orcid":null},"institutions":[{"id":"https://openalex.org/I4210124274","display_name":"Fraunhofer Institute for Integrated Circuits","ror":"https://ror.org/024ape423","country_code":"DE","type":"facility","lineage":["https://openalex.org/I4210124274","https://openalex.org/I4923324"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Eva Fordran","raw_affiliation_strings":["Fraunhofer Institute for Integrated Circuits, Design Automation Division, Zeunerstr. 38, 01069 Dresden, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Fraunhofer Institute for Integrated Circuits, Design Automation Division, Zeunerstr. 38, 01069 Dresden, Germany","institution_ids":["https://openalex.org/I4210124274"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5023592285","display_name":"Bernd Straube","orcid":null},"institutions":[{"id":"https://openalex.org/I4210124274","display_name":"Fraunhofer Institute for Integrated Circuits","ror":"https://ror.org/024ape423","country_code":"DE","type":"facility","lineage":["https://openalex.org/I4210124274","https://openalex.org/I4923324"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Bernd Straube","raw_affiliation_strings":["Fraunhofer Institute for Integrated Circuits, Design Automation Division, Zeunerstr. 38, 01069 Dresden, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Fraunhofer Institute for Integrated Circuits, Design Automation Division, Zeunerstr. 38, 01069 Dresden, Germany","institution_ids":["https://openalex.org/I4210124274"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5031920279","display_name":"J\u00fcrgen Haufe","orcid":null},"institutions":[{"id":"https://openalex.org/I4210124274","display_name":"Fraunhofer Institute for Integrated Circuits","ror":"https://ror.org/024ape423","country_code":"DE","type":"facility","lineage":["https://openalex.org/I4210124274","https://openalex.org/I4923324"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Jurgen Haufe","raw_affiliation_strings":["Fraunhofer Institute for Integrated Circuits, Design Automation Division, Zeunerstr. 38, 01069 Dresden, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Fraunhofer Institute for Integrated Circuits, Design Automation Division, Zeunerstr. 38, 01069 Dresden, Germany","institution_ids":["https://openalex.org/I4210124274"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I4210124274"],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":17,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10142","display_name":"Formal Methods in Verification","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1703","display_name":"Computational Theory and Mathematics"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10142","display_name":"Formal Methods in Verification","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1703","display_name":"Computational Theory and Mathematics"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10743","display_name":"Software Testing and Debugging Techniques","score":0.9977999925613403,"subfield":{"id":"https://openalex.org/subfields/1712","display_name":"Software"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13295","display_name":"Safety Systems Engineering in Autonomy","score":0.996999979019165,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7915977239608765},{"id":"https://openalex.org/keywords/model-checking","display_name":"Model checking","score":0.7812739014625549},{"id":"https://openalex.org/keywords/unified-modeling-language","display_name":"Unified Modeling Language","score":0.6364859342575073},{"id":"https://openalex.org/keywords/formal-verification","display_name":"Formal verification","score":0.5909066796302795},{"id":"https://openalex.org/keywords/programmable-logic-controller","display_name":"Programmable logic controller","score":0.5239639282226562},{"id":"https://openalex.org/keywords/finite-state-machine","display_name":"Finite-state machine","score":0.5079558491706848},{"id":"https://openalex.org/keywords/programming-language","display_name":"Programming language","score":0.4931051433086395},{"id":"https://openalex.org/keywords/formal-methods","display_name":"Formal methods","score":0.484408438205719},{"id":"https://openalex.org/keywords/formal-specification","display_name":"Formal specification","score":0.44456806778907776},{"id":"https://openalex.org/keywords/abstract-state-machines","display_name":"Abstract state machines","score":0.4444034695625305},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.4138382375240326},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.32502156496047974},{"id":"https://openalex.org/keywords/software","display_name":"Software","score":0.17238834500312805},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.16092437505722046}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7915977239608765},{"id":"https://openalex.org/C110251889","wikidata":"https://www.wikidata.org/wiki/Q1569697","display_name":"Model checking","level":2,"score":0.7812739014625549},{"id":"https://openalex.org/C145644426","wikidata":"https://www.wikidata.org/wiki/Q169411","display_name":"Unified Modeling Language","level":3,"score":0.6364859342575073},{"id":"https://openalex.org/C111498074","wikidata":"https://www.wikidata.org/wiki/Q173326","display_name":"Formal verification","level":2,"score":0.5909066796302795},{"id":"https://openalex.org/C37374048","wikidata":"https://www.wikidata.org/wiki/Q188674","display_name":"Programmable logic controller","level":2,"score":0.5239639282226562},{"id":"https://openalex.org/C167822520","wikidata":"https://www.wikidata.org/wiki/Q176452","display_name":"Finite-state machine","level":2,"score":0.5079558491706848},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.4931051433086395},{"id":"https://openalex.org/C75606506","wikidata":"https://www.wikidata.org/wiki/Q1049183","display_name":"Formal methods","level":2,"score":0.484408438205719},{"id":"https://openalex.org/C116253237","wikidata":"https://www.wikidata.org/wiki/Q1437424","display_name":"Formal specification","level":2,"score":0.44456806778907776},{"id":"https://openalex.org/C145243422","wikidata":"https://www.wikidata.org/wiki/Q333385","display_name":"Abstract state machines","level":3,"score":0.4444034695625305},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.4138382375240326},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.32502156496047974},{"id":"https://openalex.org/C2777904410","wikidata":"https://www.wikidata.org/wiki/Q7397","display_name":"Software","level":2,"score":0.17238834500312805},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.16092437505722046},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0}],"mesh":[],"locations_count":5,"locations":[{"id":"doi:10.1109/etfa.2009.5347044","is_oa":false,"landing_page_url":"https://doi.org/10.1109/etfa.2009.5347044","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2009 IEEE Conference on Emerging Technologies &amp; Factory Automation","raw_type":"proceedings-article"},{"id":"pmh:oai:fraunhofer.de:N-105235","is_oa":false,"landing_page_url":"http://publica.fraunhofer.de/documents/N-105235.html","pdf_url":null,"source":{"id":"https://openalex.org/S4306400801","display_name":"Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4923324","host_organization_name":"Fraunhofer-Gesellschaft","host_organization_lineage":["https://openalex.org/I4923324"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Fraunhofer EAS","raw_type":"Conference Paper"},{"id":"pmh:oai:fraunhofer.de:N-120647","is_oa":false,"landing_page_url":"http://publica.fraunhofer.de/documents/N-120647.html","pdf_url":null,"source":{"id":"https://openalex.org/S4306400801","display_name":"Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4923324","host_organization_name":"Fraunhofer-Gesellschaft","host_organization_lineage":["https://openalex.org/I4923324"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Fraunhofer EAS","raw_type":"Thesis"},{"id":"pmh:oai:publica.fraunhofer.de:publica/278333","is_oa":false,"landing_page_url":"https://publica.fraunhofer.de/handle/publica/278333","pdf_url":null,"source":{"id":"https://openalex.org/S4306400318","display_name":"Fraunhofer-Publica (Fraunhofer-Gesellschaft)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4923324","host_organization_name":"Fraunhofer-Gesellschaft","host_organization_lineage":["https://openalex.org/I4923324"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"diploma thesis"},{"id":"pmh:oai:publica.fraunhofer.de:publica/362716","is_oa":false,"landing_page_url":"https://publica.fraunhofer.de/handle/publica/362716","pdf_url":null,"source":{"id":"https://openalex.org/S4306400318","display_name":"Fraunhofer-Publica (Fraunhofer-Gesellschaft)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4923324","host_organization_name":"Fraunhofer-Gesellschaft","host_organization_lineage":["https://openalex.org/I4923324"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"conference paper"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":27,"referenced_works":["https://openalex.org/W3453007","https://openalex.org/W1489391022","https://openalex.org/W1503170978","https://openalex.org/W1530797069","https://openalex.org/W1550024445","https://openalex.org/W1565408100","https://openalex.org/W1970603830","https://openalex.org/W1986517062","https://openalex.org/W2000138546","https://openalex.org/W2009129255","https://openalex.org/W2097246682","https://openalex.org/W2101508170","https://openalex.org/W2147354115","https://openalex.org/W2149402364","https://openalex.org/W2156256666","https://openalex.org/W2257734719","https://openalex.org/W2340735175","https://openalex.org/W2344671925","https://openalex.org/W2460918602","https://openalex.org/W2913459036","https://openalex.org/W3185313291","https://openalex.org/W6600147949","https://openalex.org/W6632943050","https://openalex.org/W6633920899","https://openalex.org/W6681845041","https://openalex.org/W6692358021","https://openalex.org/W6704706996"],"related_works":["https://openalex.org/W1524361563","https://openalex.org/W1504525241","https://openalex.org/W1972360043","https://openalex.org/W2741430969","https://openalex.org/W3203410543","https://openalex.org/W2156256666","https://openalex.org/W2039064891","https://openalex.org/W2369289949","https://openalex.org/W2526626111","https://openalex.org/W2303036583"],"abstract_inverted_index":{"Programmable":[0],"logic":[1],"controllers":[2],"(PLCs)":[3],"are":[4,39],"applied":[5],"in":[6,90],"a":[7,55,75,109],"wide":[8],"field":[9],"of":[10,25,31,65,92,122],"application":[11],"and,":[12],"especially,":[13],"for":[14,22,52,113],"safety-critical":[15],"controls.":[16,84],"Thus,":[17],"there":[18],"is":[19,68,88],"the":[20,28,32,36,62,101,114,120,123],"demand":[21],"high":[23],"reliability":[24],"PLCs.":[26],"Moreover,":[27],"increasing":[29],"complexity":[30],"PLC":[33,56,66,86],"programs":[34,67],"and":[35,70],"short":[37],"time-to-market":[38],"hard":[40],"to":[41,78,82,103],"cope":[42],"with.":[43],"Formal":[44],"verification":[45],"techniques":[46],"such":[47],"as":[48,100],"model":[49,80,112,115],"checking":[50,81],"allow":[51],"proving":[53],"whether":[54],"program":[57,87],"meets":[58],"its":[59],"specification.":[60],"However,":[61],"manual":[63],"formalization":[64],"error-prone":[69],"time-consuming.":[71],"This":[72],"paper":[73],"presents":[74],"novel":[76],"approach":[77,125],"apply":[79],"machine":[83,129],"The":[85],"modeled":[89],"form":[91],"Unified":[93],"Modeling":[94],"Language":[95],"(UML)":[96],"state-charts":[97],"that":[98,106],"serve":[99],"input":[102],"our":[104],"tool":[105],"automatically":[107],"generates":[108],"corresponding":[110],"formal":[111],"checker":[116],"NuSMV.":[117],"We":[118],"evaluate":[119],"capabilities":[121],"proposed":[124],"on":[126],"an":[127],"industrial":[128],"control.":[130]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":2},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":2},{"year":2014,"cited_by_count":2},{"year":2013,"cited_by_count":2},{"year":2012,"cited_by_count":1}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
