{"id":"https://openalex.org/W4405489533","doi":"https://doi.org/10.1109/embc53108.2024.10782659","title":"Development of an electro-pneumatic calf muscle actuator to estimate peripheral venous oxygen saturation using photoplethysmography","display_name":"Development of an electro-pneumatic calf muscle actuator to estimate peripheral venous oxygen saturation using photoplethysmography","publication_year":2024,"publication_date":"2024-07-15","ids":{"openalex":"https://openalex.org/W4405489533","doi":"https://doi.org/10.1109/embc53108.2024.10782659","pmid":"https://pubmed.ncbi.nlm.nih.gov/40039866"},"language":"en","primary_location":{"id":"doi:10.1109/embc53108.2024.10782659","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc53108.2024.10782659","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 46th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5071691649","display_name":"Idoia Badiola","orcid":"https://orcid.org/0000-0003-2319-7013"},"institutions":[{"id":"https://openalex.org/I887968799","display_name":"RWTH Aachen University","ror":"https://ror.org/04xfq0f34","country_code":"DE","type":"education","lineage":["https://openalex.org/I887968799"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Idoia Badiola","raw_affiliation_strings":["RWTH Aachen University,Medical Information Technology (MedIT),Aachen,Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"RWTH Aachen University,Medical Information Technology (MedIT),Aachen,Germany","institution_ids":["https://openalex.org/I887968799"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5115513470","display_name":"Stefan Noppeney","orcid":null},"institutions":[{"id":"https://openalex.org/I887968799","display_name":"RWTH Aachen University","ror":"https://ror.org/04xfq0f34","country_code":"DE","type":"education","lineage":["https://openalex.org/I887968799"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Stefan Noppeney","raw_affiliation_strings":["RWTH Aachen University,Medical Information Technology (MedIT),Aachen,Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"RWTH Aachen University,Medical Information Technology (MedIT),Aachen,Germany","institution_ids":["https://openalex.org/I887968799"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5044093687","display_name":"Vladim\u00edr Bla\u017eek","orcid":null},"institutions":[{"id":"https://openalex.org/I887968799","display_name":"RWTH Aachen University","ror":"https://ror.org/04xfq0f34","country_code":"DE","type":"education","lineage":["https://openalex.org/I887968799"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Vladimir Blazek","raw_affiliation_strings":["RWTH Aachen University,Medical Information Technology (MedIT),Aachen,Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"RWTH Aachen University,Medical Information Technology (MedIT),Aachen,Germany","institution_ids":["https://openalex.org/I887968799"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5060021065","display_name":"Steffen Leonhardt","orcid":"https://orcid.org/0000-0002-6898-6887"},"institutions":[{"id":"https://openalex.org/I887968799","display_name":"RWTH Aachen University","ror":"https://ror.org/04xfq0f34","country_code":"DE","type":"education","lineage":["https://openalex.org/I887968799"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Steffen Leonhardt","raw_affiliation_strings":["RWTH Aachen University,Medical Information Technology (MedIT),Aachen,Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"RWTH Aachen University,Medical Information Technology (MedIT),Aachen,Germany","institution_ids":["https://openalex.org/I887968799"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5045468101","display_name":"Markus Lueken","orcid":"https://orcid.org/0000-0002-2487-0962"},"institutions":[{"id":"https://openalex.org/I887968799","display_name":"RWTH Aachen University","ror":"https://ror.org/04xfq0f34","country_code":"DE","type":"education","lineage":["https://openalex.org/I887968799"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Markus Lueken","raw_affiliation_strings":["RWTH Aachen University,Medical Information Technology (MedIT),Aachen,Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"RWTH Aachen University,Medical Information Technology (MedIT),Aachen,Germany","institution_ids":["https://openalex.org/I887968799"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I887968799"],"apc_list":null,"apc_paid":null,"fwci":1.0515,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.78632256,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":95},"biblio":{"volume":"2024","issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.9980999827384949,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/photoplethysmogram","display_name":"Photoplethysmogram","score":0.9236781597137451},{"id":"https://openalex.org/keywords/peripheral","display_name":"Peripheral","score":0.5967574715614319},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.5404217839241028},{"id":"https://openalex.org/keywords/saturation","display_name":"Saturation (graph theory)","score":0.425983190536499},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.4245133399963379},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.3864995241165161},{"id":"https://openalex.org/keywords/cardiology","display_name":"Cardiology","score":0.370322585105896},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.3647778034210205},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.33438459038734436},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.23085150122642517},{"id":"https://openalex.org/keywords/internal-medicine","display_name":"Internal medicine","score":0.22733330726623535},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.181198388338089},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.08776572346687317},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.07654771208763123}],"concepts":[{"id":"https://openalex.org/C116390426","wikidata":"https://www.wikidata.org/wiki/Q7187885","display_name":"Photoplethysmogram","level":3,"score":0.9236781597137451},{"id":"https://openalex.org/C46762472","wikidata":"https://www.wikidata.org/wiki/Q178648","display_name":"Peripheral","level":2,"score":0.5967574715614319},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.5404217839241028},{"id":"https://openalex.org/C9930424","wikidata":"https://www.wikidata.org/wiki/Q7426587","display_name":"Saturation (graph theory)","level":2,"score":0.425983190536499},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.4245133399963379},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.3864995241165161},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.370322585105896},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.3647778034210205},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.33438459038734436},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.23085150122642517},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.22733330726623535},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.181198388338089},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.08776572346687317},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.07654771208763123},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C114614502","wikidata":"https://www.wikidata.org/wiki/Q76592","display_name":"Combinatorics","level":1,"score":0.0},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.0}],"mesh":[{"descriptor_ui":"D000089382","descriptor_name":"Oxygen Saturation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000089382","descriptor_name":"Oxygen Saturation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000089382","descriptor_name":"Oxygen Saturation","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":true},{"descriptor_ui":"D000089382","descriptor_name":"Oxygen Saturation","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":true},{"descriptor_ui":"D000328","descriptor_name":"Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001810","descriptor_name":"Blood Volume","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001810","descriptor_name":"Blood Volume","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007866","descriptor_name":"Leg","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007866","descriptor_name":"Leg","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007866","descriptor_name":"Leg","qualifier_ui":"Q000098","qualifier_name":"blood supply","is_major_topic":true},{"descriptor_ui":"D007866","descriptor_name":"Leg","qualifier_ui":"Q000098","qualifier_name":"blood supply","is_major_topic":false},{"descriptor_ui":"D008297","descriptor_name":"Male","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008297","descriptor_name":"Male","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D010100","descriptor_name":"Oxygen","qualifier_ui":"Q000097","qualifier_name":"blood","is_major_topic":true},{"descriptor_ui":"D010100","descriptor_name":"Oxygen","qualifier_ui":"Q000097","qualifier_name":"blood","is_major_topic":false},{"descriptor_ui":"D014680","descriptor_name":"Veins","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":true},{"descriptor_ui":"D014680","descriptor_name":"Veins","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":true},{"descriptor_ui":"D014680","descriptor_name":"Veins","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":true},{"descriptor_ui":"D014680","descriptor_name":"Veins","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D017156","descriptor_name":"Photoplethysmography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D017156","descriptor_name":"Photoplethysmography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D017156","descriptor_name":"Photoplethysmography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D017156","descriptor_name":"Photoplethysmography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D017156","descriptor_name":"Photoplethysmography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D017156","descriptor_name":"Photoplethysmography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D018482","descriptor_name":"Muscle, Skeletal","qualifier_ui":"Q000098","qualifier_name":"blood supply","is_major_topic":true},{"descriptor_ui":"D018482","descriptor_name":"Muscle, Skeletal","qualifier_ui":"Q000098","qualifier_name":"blood supply","is_major_topic":true},{"descriptor_ui":"D018482","descriptor_name":"Muscle, Skeletal","qualifier_ui":"Q000098","qualifier_name":"blood supply","is_major_topic":false},{"descriptor_ui":"D018482","descriptor_name":"Muscle, Skeletal","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":true},{"descriptor_ui":"D018482","descriptor_name":"Muscle, Skeletal","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":true},{"descriptor_ui":"D018482","descriptor_name":"Muscle, Skeletal","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":true},{"descriptor_ui":"D018482","descriptor_name":"Muscle, Skeletal","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/embc53108.2024.10782659","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc53108.2024.10782659","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 46th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},{"id":"pmid:40039866","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/40039866","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W2083872334","https://openalex.org/W2296287625","https://openalex.org/W4251085419","https://openalex.org/W4386925088"],"related_works":["https://openalex.org/W2732360296","https://openalex.org/W1994871954","https://openalex.org/W4297152434","https://openalex.org/W2072858761","https://openalex.org/W1540261775","https://openalex.org/W4239033438","https://openalex.org/W1968279762","https://openalex.org/W4318970012","https://openalex.org/W2067862553","https://openalex.org/W2777534421"],"abstract_inverted_index":{"In":[0],"pulse":[1],"oximetry,":[2],"arterial":[3,11,104],"blood":[4,35,58,92],"pulsations":[5,66],"are":[6,153],"used":[7],"to":[8,30,55,96,168],"estimate":[9],"peripheral":[10,21],"oxygen":[12,23,115],"saturation":[13,24],"(SpO2)":[14],"using":[15],"photoplethysmography":[16],"(PPG).":[17],"On":[18],"the":[19,31,39,49,68,111,157,165],"contrary,":[20],"venous":[22,40,57,91,170],"(SvO2)":[25],"assessment":[26],"remains":[27],"challenging":[28],"due":[29],"absence":[32],"of":[33,113],"rhythmic":[34],"volume":[36,93],"fluctuations":[37],"in":[38,102],"system.":[41],"This":[42],"paper":[43],"introduces":[44],"an":[45],"electro-pneumatic":[46],"system":[47,61,100],"emulating":[48],"Venous":[50],"Muscle":[51],"Pump":[52],"Test":[53],"(VMPT)":[54],"induce":[56],"pulsations.":[59],"The":[60,99],"achieves":[62],"0-120":[63],"mmHg":[64],"pressure":[65,147],"on":[67,84],"calf":[69],"at":[70],"0.5":[71],"Hz,":[72],"facilitating":[73],"SvO2":[74,121,151],"estimation":[75,109],"through":[76],"a":[77],"toe-attached":[78],"PPG":[79,88],"sensor.":[80],"A":[81],"proof-of-concept":[82],"study":[83],"two":[85],"subjects":[86],"reveals":[87],"curves":[89],"and":[90,110,120,149],"variations":[94],"comparable":[95],"conventional":[97],"VMPT.":[98],"outperforms":[101],"acquiring":[103],"pulsations,":[105],"enabling":[106],"simultaneous":[107],"SpO2":[108],"possibility":[112],"local":[114],"consumption":[116],"estimation.":[117],"Estimated":[118],"Ratio-of-Modulation":[119],"values":[122,152],"(84-89":[123],"%)":[124],"align":[125],"with":[126,129,142],"classical":[127],"VMPT,":[128],"lower":[130],"mean":[131],"deviation":[132],"(3-15":[133],"%":[134],"vs.":[135],"10-18":[136],"%).":[137],"While":[138],"promising,":[139],"further":[140,163],"studies":[141],"larger":[143],"sample":[144],"sizes,":[145],"varied":[146],"parameters,":[148],"reference":[150],"essential":[154],"for":[155],"validating":[156],"system's":[158,166],"efficacy.":[159],"Future":[160],"tests":[161],"will":[162],"explore":[164],"potential":[167],"detect":[169],"valve":[171],"leakage.":[172]},"counts_by_year":[{"year":2025,"cited_by_count":1}],"updated_date":"2026-07-31T08:31:51.225901","created_date":"2025-10-10T00:00:00"}
