{"id":"https://openalex.org/W4200439110","doi":"https://doi.org/10.1109/embc46164.2021.9630768","title":"Ultra Low Power Photometry for Pulse Oximetry Applications","display_name":"Ultra Low Power Photometry for Pulse Oximetry Applications","publication_year":2021,"publication_date":"2021-11-01","ids":{"openalex":"https://openalex.org/W4200439110","doi":"https://doi.org/10.1109/embc46164.2021.9630768","pmid":"https://pubmed.ncbi.nlm.nih.gov/34892806"},"language":"en","primary_location":{"id":"doi:10.1109/embc46164.2021.9630768","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc46164.2021.9630768","pdf_url":null,"source":{"id":"https://openalex.org/S4363607750","display_name":"2021 43rd Annual International Conference of the IEEE Engineering in Medicine &amp; Biology Society (EMBC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 43rd Annual International Conference of the IEEE Engineering in Medicine &amp; Biology Society (EMBC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"John O'Donnell","orcid":null},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"John O'Donnell","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"last","author":{"id":null,"display_name":"John Nelson","orcid":null},"institutions":[{"id":"https://openalex.org/I230495080","display_name":"University of Limerick","ror":"https://ror.org/00a0n9e72","country_code":"IE","type":"education","lineage":["https://openalex.org/I230495080"]}],"countries":["IE"],"is_corresponding":false,"raw_author_name":"John Nelson","raw_affiliation_strings":["University of Limerick, Ireland"],"affiliations":[{"raw_affiliation_string":"University of Limerick, Ireland","institution_ids":["https://openalex.org/I230495080"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.22949567,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"pp","issue":null,"first_page":"7394","last_page":"7398"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9693999886512756,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9693999886512756,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.003800000064074993,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11932","display_name":"Wireless Body Area Networks","score":0.00279999990016222,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/pulse-oximetry","display_name":"Pulse oximetry","score":0.5866000056266785},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.4860999882221222},{"id":"https://openalex.org/keywords/inductor","display_name":"Inductor","score":0.4212999939918518},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4156999886035919},{"id":"https://openalex.org/keywords/electronic-circuit","display_name":"Electronic circuit","score":0.41260001063346863},{"id":"https://openalex.org/keywords/resistive-touchscreen","display_name":"Resistive touchscreen","score":0.39399999380111694},{"id":"https://openalex.org/keywords/heartbeat","display_name":"Heartbeat","score":0.38679999113082886},{"id":"https://openalex.org/keywords/battery","display_name":"Battery (electricity)","score":0.3806000053882599},{"id":"https://openalex.org/keywords/remote-patient-monitoring","display_name":"Remote patient monitoring","score":0.3747999966144562},{"id":"https://openalex.org/keywords/pulsed-power","display_name":"Pulsed power","score":0.33160001039505005}],"concepts":[{"id":"https://openalex.org/C2780124106","wikidata":"https://www.wikidata.org/wiki/Q1140495","display_name":"Pulse oximetry","level":2,"score":0.5866000056266785},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.4860999882221222},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.484499990940094},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.45829999446868896},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.43320000171661377},{"id":"https://openalex.org/C144534570","wikidata":"https://www.wikidata.org/wiki/Q5325","display_name":"Inductor","level":3,"score":0.4212999939918518},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4156999886035919},{"id":"https://openalex.org/C134146338","wikidata":"https://www.wikidata.org/wiki/Q1815901","display_name":"Electronic circuit","level":2,"score":0.41260001063346863},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4108999967575073},{"id":"https://openalex.org/C6899612","wikidata":"https://www.wikidata.org/wiki/Q852911","display_name":"Resistive touchscreen","level":2,"score":0.39399999380111694},{"id":"https://openalex.org/C13852961","wikidata":"https://www.wikidata.org/wiki/Q17021880","display_name":"Heartbeat","level":2,"score":0.38679999113082886},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.3806000053882599},{"id":"https://openalex.org/C175079658","wikidata":"https://www.wikidata.org/wiki/Q7312165","display_name":"Remote patient monitoring","level":2,"score":0.3747999966144562},{"id":"https://openalex.org/C97039730","wikidata":"https://www.wikidata.org/wiki/Q552565","display_name":"Pulsed power","level":3,"score":0.33160001039505005},{"id":"https://openalex.org/C2776257435","wikidata":"https://www.wikidata.org/wiki/Q1576430","display_name":"Bandwidth (computing)","level":2,"score":0.33079999685287476},{"id":"https://openalex.org/C3017539923","wikidata":"https://www.wikidata.org/wiki/Q1140495","display_name":"Blood oxygenation","level":3,"score":0.3222000002861023},{"id":"https://openalex.org/C2776902269","wikidata":"https://www.wikidata.org/wiki/Q5165493","display_name":"Continuous monitoring","level":2,"score":0.3093999922275543},{"id":"https://openalex.org/C76538665","wikidata":"https://www.wikidata.org/wiki/Q6294669","display_name":"Oxygen saturation","level":3,"score":0.30709999799728394},{"id":"https://openalex.org/C2780167933","wikidata":"https://www.wikidata.org/wiki/Q1550652","display_name":"Pulse (music)","level":3,"score":0.3046000003814697},{"id":"https://openalex.org/C2781331714","wikidata":"https://www.wikidata.org/wiki/Q1163768","display_name":"Current source","level":3,"score":0.296099990606308},{"id":"https://openalex.org/C172321821","wikidata":"https://www.wikidata.org/wiki/Q7259685","display_name":"Pulse wave","level":3,"score":0.29409998655319214},{"id":"https://openalex.org/C173018170","wikidata":"https://www.wikidata.org/wiki/Q165678","display_name":"Microcontroller","level":2,"score":0.2865999937057495},{"id":"https://openalex.org/C182862853","wikidata":"https://www.wikidata.org/wiki/Q575887","display_name":"Pulse repetition frequency","level":3,"score":0.2793000042438507},{"id":"https://openalex.org/C163985040","wikidata":"https://www.wikidata.org/wiki/Q1172399","display_name":"Data acquisition","level":2,"score":0.27869999408721924},{"id":"https://openalex.org/C2777048131","wikidata":"https://www.wikidata.org/wiki/Q321098","display_name":"Laser diode","level":3,"score":0.27480000257492065},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.2728999853134155},{"id":"https://openalex.org/C9390403","wikidata":"https://www.wikidata.org/wiki/Q3966","display_name":"Computer hardware","level":1,"score":0.26840001344680786},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.2660999894142151},{"id":"https://openalex.org/C80264047","wikidata":"https://www.wikidata.org/wiki/Q7424019","display_name":"Pressure measurement","level":2,"score":0.26570001244544983},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.265500009059906},{"id":"https://openalex.org/C186967261","wikidata":"https://www.wikidata.org/wiki/Q5082128","display_name":"Mobile device","level":2,"score":0.2565999925136566},{"id":"https://openalex.org/C55000061","wikidata":"https://www.wikidata.org/wiki/Q24894777","display_name":"Current sensor","level":3,"score":0.25440001487731934}],"mesh":[{"descriptor_ui":"D000089382","descriptor_name":"Oxygen Saturation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000089382","descriptor_name":"Oxygen Saturation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000089382","descriptor_name":"Oxygen Saturation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D010100","descriptor_name":"Oxygen","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010100","descriptor_name":"Oxygen","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010100","descriptor_name":"Oxygen","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010783","descriptor_name":"Photometry","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010783","descriptor_name":"Photometry","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010783","descriptor_name":"Photometry","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/embc46164.2021.9630768","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc46164.2021.9630768","pdf_url":null,"source":{"id":"https://openalex.org/S4363607750","display_name":"2021 43rd Annual International Conference of the IEEE Engineering in Medicine &amp; Biology Society (EMBC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 43rd Annual International Conference of the IEEE Engineering in Medicine &amp; Biology Society (EMBC)","raw_type":"proceedings-article"},{"id":"pmid:34892806","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/34892806","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320321056","display_name":"Irish Research Council","ror":"https://ror.org/051xex213"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W1963522855","https://openalex.org/W1979172081","https://openalex.org/W2034894433","https://openalex.org/W2291754381","https://openalex.org/W2318062962","https://openalex.org/W2906641123","https://openalex.org/W2907764951","https://openalex.org/W6673331287","https://openalex.org/W6713807463","https://openalex.org/W6755474474"],"related_works":[],"abstract_inverted_index":{"Removing":[0],"patient":[1,189],"cables":[2],"from":[3],"the":[4,8,21,72,89,103,117,136,146,173,188,191],"hospital":[5],"environment,":[6],"through":[7],"use":[9],"of":[10,49,71,100,139,149,187],"wireless":[11,175],"sensors,":[12],"improves":[13,180],"hygiene,":[14,181],"convenience":[15,182],"and":[16,56,67,81,91,126,145,161],"standard-of-care":[17],"[1]":[18],"[2].":[19],"In":[20],"drive":[22],"to":[23,93,116],"eliminate":[24],"cable":[25],"clutter,":[26],"vital":[27],"signs":[28],"monitoring":[29],"(VSM)":[30],"is":[31,37,83,122,154],"\"going":[32],"wireless.\"":[33],"This,":[34],"in":[35,102,124,178,190],"turn,":[36,179],"driving":[38],"a":[39,61,86,140,150],"trend":[40],"for":[41,64,98,172],"battery":[42,170],"powered":[43],"VSM":[44,176],"sensors":[45,59],"such":[46],"as":[47],"Saturation":[48],"Peripheral":[50],"Oxygen":[51],"(SpO2),":[52],"Blood":[53],"Pressure":[54],"(BP),":[55],"Electro-cardiogram":[57],"(ECG)":[58],"with":[60,85,156],"resultant":[62],"demand":[63],"ultra-low-power":[65],"circuits":[66],"algorithms.":[68],"The":[69,165],"architecture":[70],"optical":[73],"SpO2":[74,174],"pulse":[75,104,120],"oximeter,":[76],"which":[77,111,134],"measures":[78],"blood":[79],"oxygenation":[80],"heartrate,":[82],"described":[84],"focus":[87],"on":[88],"drivers":[90],"contributors":[92],"system":[94,147,162],"power.":[95],"Two":[96],"concepts":[97],"reduction":[99],"power":[101,137],"oximeter":[105],"are":[106],"explored.":[107],"Firstly,":[108],"an":[109,129],"algorithm":[110],"modulates":[112],"LED":[113,132],"current":[114,143,152],"according":[115],"instantaneous":[118],"heartbeat":[119],"phase":[121],"demonstrated":[123,158],"hardware":[125],"software.":[127],"Secondly,":[128],"inductor":[130],"centric":[131],"driver,":[133],"provides":[135],"efficiency":[138],"switched":[141],"mode":[142],"source":[144,153],"accuracy":[148],"linear":[151],"introduced":[155],"feasibility":[157],"by":[159],"circuit":[160],"simulation.Clinical":[163],"Relevance-":[164],"techniques":[166],"discussed":[167],"enable":[168],"longer":[169],"life":[171],"which,":[177],"and,":[183],"most":[184],"importantly,":[185],"mobility":[186],"clinical":[192],"setting.":[193]},"counts_by_year":[],"updated_date":"2026-04-09T08:11:56.329763","created_date":"2021-12-31T00:00:00"}
