{"id":"https://openalex.org/W2979333732","doi":"https://doi.org/10.1109/embc.2019.8857530","title":"Effectiveness of CRT-D Versus ICD on Prevention of Electrical Storm: Big Data from the USA","display_name":"Effectiveness of CRT-D Versus ICD on Prevention of Electrical Storm: Big Data from the USA","publication_year":2019,"publication_date":"2019-07-01","ids":{"openalex":"https://openalex.org/W2979333732","doi":"https://doi.org/10.1109/embc.2019.8857530","mag":"2979333732","pmid":"https://pubmed.ncbi.nlm.nih.gov/31945901"},"language":"en","primary_location":{"id":"doi:10.1109/embc.2019.8857530","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2019.8857530","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5026753572","display_name":"Saeed Shakibfar","orcid":"https://orcid.org/0000-0001-8399-0318"},"institutions":[{"id":"https://openalex.org/I124055696","display_name":"University of Copenhagen","ror":"https://ror.org/035b05819","country_code":"DK","type":"education","lineage":["https://openalex.org/I124055696"]}],"countries":["DK"],"is_corresponding":true,"raw_author_name":"Saeed Shakibfar","raw_affiliation_strings":["Department of Computer Science, University of Copenhagen Denmark, K&#x00F8;benhavn &#x00D8;, 2100, Denmark"],"affiliations":[{"raw_affiliation_string":"Department of Computer Science, University of Copenhagen Denmark, K&#x00F8;benhavn &#x00D8;, 2100, Denmark","institution_ids":["https://openalex.org/I124055696"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5072430825","display_name":"Mohammadreza Yazdchi","orcid":"https://orcid.org/0000-0001-8015-2124"},"institutions":[{"id":"https://openalex.org/I39268498","display_name":"University of Isfahan","ror":"https://ror.org/05h9t7759","country_code":"IR","type":"education","lineage":["https://openalex.org/I39268498"]}],"countries":["IR"],"is_corresponding":false,"raw_author_name":"Mohammadreza Yazdchi","raw_affiliation_strings":["Department of Biomedical Engineering. Faculty of Engineering, University of Isfahan HezarJerib, St.-Isfahan, Iran"],"affiliations":[{"raw_affiliation_string":"Department of Biomedical Engineering. Faculty of Engineering, University of Isfahan HezarJerib, St.-Isfahan, Iran","institution_ids":["https://openalex.org/I39268498"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5015738387","display_name":"Susan Aliakbaryhosseinabadi","orcid":"https://orcid.org/0000-0002-5034-160X"},"institutions":[{"id":"https://openalex.org/I891191580","display_name":"Aalborg University","ror":"https://ror.org/04m5j1k67","country_code":"DK","type":"education","lineage":["https://openalex.org/I891191580"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"Susan Aliakbaryhosseinabadi","raw_affiliation_strings":["Center for Sensory-Motor Interaction, Department of Health Science and Technology, Faculty of Medicine, Aalborg University, Aalborg, Denmark"],"affiliations":[{"raw_affiliation_string":"Center for Sensory-Motor Interaction, Department of Health Science and Technology, Faculty of Medicine, Aalborg University, Aalborg, Denmark","institution_ids":["https://openalex.org/I891191580"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5026753572"],"corresponding_institution_ids":["https://openalex.org/I124055696"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.19507719,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"37","issue":null,"first_page":"302","last_page":"304"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10598","display_name":"Cardiac pacing and defibrillation studies","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10598","display_name":"Cardiac pacing and defibrillation studies","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10217","display_name":"Cardiac electrophysiology and arrhythmias","score":0.9918000102043152,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10919","display_name":"Neurological disorders and treatments","score":0.9835000038146973,"subfield":{"id":"https://openalex.org/subfields/2728","display_name":"Neurology"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/cardiac-resynchronization-therapy","display_name":"Cardiac resynchronization therapy","score":0.8320356607437134},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.8096455335617065},{"id":"https://openalex.org/keywords/implantable-cardioverter-defibrillator","display_name":"Implantable cardioverter-defibrillator","score":0.641274094581604},{"id":"https://openalex.org/keywords/proportional-hazards-model","display_name":"Proportional hazards model","score":0.6367425322532654},{"id":"https://openalex.org/keywords/internal-medicine","display_name":"Internal medicine","score":0.6049437522888184},{"id":"https://openalex.org/keywords/cardiology","display_name":"Cardiology","score":0.6041918396949768},{"id":"https://openalex.org/keywords/hazard-ratio","display_name":"Hazard ratio","score":0.5877681970596313},{"id":"https://openalex.org/keywords/clinical-endpoint","display_name":"Clinical endpoint","score":0.4518147110939026},{"id":"https://openalex.org/keywords/implant","display_name":"Implant","score":0.42086225748062134},{"id":"https://openalex.org/keywords/heart-failure","display_name":"Heart failure","score":0.2627742290496826},{"id":"https://openalex.org/keywords/surgery","display_name":"Surgery","score":0.2184387445449829},{"id":"https://openalex.org/keywords/confidence-interval","display_name":"Confidence interval","score":0.21034401655197144},{"id":"https://openalex.org/keywords/ejection-fraction","display_name":"Ejection fraction","score":0.1413441300392151},{"id":"https://openalex.org/keywords/clinical-trial","display_name":"Clinical trial","score":0.13440489768981934}],"concepts":[{"id":"https://openalex.org/C2776034619","wikidata":"https://www.wikidata.org/wiki/Q3428020","display_name":"Cardiac resynchronization therapy","level":4,"score":0.8320356607437134},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.8096455335617065},{"id":"https://openalex.org/C2777093960","wikidata":"https://www.wikidata.org/wiki/Q594446","display_name":"Implantable cardioverter-defibrillator","level":2,"score":0.641274094581604},{"id":"https://openalex.org/C50382708","wikidata":"https://www.wikidata.org/wiki/Q223218","display_name":"Proportional hazards model","level":2,"score":0.6367425322532654},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.6049437522888184},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.6041918396949768},{"id":"https://openalex.org/C207103383","wikidata":"https://www.wikidata.org/wiki/Q3930246","display_name":"Hazard ratio","level":3,"score":0.5877681970596313},{"id":"https://openalex.org/C203092338","wikidata":"https://www.wikidata.org/wiki/Q1340863","display_name":"Clinical endpoint","level":3,"score":0.4518147110939026},{"id":"https://openalex.org/C2781411149","wikidata":"https://www.wikidata.org/wiki/Q486975","display_name":"Implant","level":2,"score":0.42086225748062134},{"id":"https://openalex.org/C2778198053","wikidata":"https://www.wikidata.org/wiki/Q181754","display_name":"Heart failure","level":2,"score":0.2627742290496826},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.2184387445449829},{"id":"https://openalex.org/C44249647","wikidata":"https://www.wikidata.org/wiki/Q208498","display_name":"Confidence interval","level":2,"score":0.21034401655197144},{"id":"https://openalex.org/C78085059","wikidata":"https://www.wikidata.org/wiki/Q641303","display_name":"Ejection fraction","level":3,"score":0.1413441300392151},{"id":"https://openalex.org/C535046627","wikidata":"https://www.wikidata.org/wiki/Q30612","display_name":"Clinical trial","level":2,"score":0.13440489768981934}],"mesh":[{"descriptor_ui":"D000077558","descriptor_name":"Big Data","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000077558","descriptor_name":"Big Data","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000077558","descriptor_name":"Big Data","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D006333","descriptor_name":"Heart Failure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006333","descriptor_name":"Heart Failure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006333","descriptor_name":"Heart Failure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011788","descriptor_name":"Quality of Life","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011788","descriptor_name":"Quality of Life","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011788","descriptor_name":"Quality of Life","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012307","descriptor_name":"Risk Factors","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012307","descriptor_name":"Risk Factors","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012307","descriptor_name":"Risk Factors","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D016896","descriptor_name":"Treatment Outcome","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D016896","descriptor_name":"Treatment Outcome","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D016896","descriptor_name":"Treatment Outcome","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017147","descriptor_name":"Defibrillators, Implantable","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017147","descriptor_name":"Defibrillators, Implantable","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017147","descriptor_name":"Defibrillators, Implantable","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D058406","descriptor_name":"Cardiac Resynchronization Therapy","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D058406","descriptor_name":"Cardiac Resynchronization Therapy","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D058406","descriptor_name":"Cardiac Resynchronization Therapy","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D058409","descriptor_name":"Cardiac Resynchronization Therapy Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D058409","descriptor_name":"Cardiac Resynchronization Therapy Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D058409","descriptor_name":"Cardiac Resynchronization Therapy Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":4,"locations":[{"id":"doi:10.1109/embc.2019.8857530","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2019.8857530","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},{"id":"pmid:31945901","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/31945901","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null},{"id":"pmh:oai:pure.atira.dk:openaire_cris_publications/292b8882-c9e6-4675-b1fb-7d1525d28589","is_oa":false,"landing_page_url":"https://researchprofiles.ku.dk/da/publications/292b8882-c9e6-4675-b1fb-7d1525d28589","pdf_url":null,"source":{"id":"https://openalex.org/S4306401983","display_name":"Research at the University of Copenhagen (University of Copenhagen)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I124055696","host_organization_name":"University of Copenhagen","host_organization_lineage":["https://openalex.org/I124055696"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Shakibfar , S , Yazdchi , M & Aliakbaryhosseinabadi , S 2019 , Effectiveness of CRT-D Versus ICD on Prevention of Electrical Storm : Big Data from the USA . in 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2019 . , 8857530 , Institute of Electrical and Electronics Engineers Inc. , pp. 302-304 , 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2019 , Berlin , Germany , 23/07/2019 . https://doi.org/10.1109/EMBC.2019.8857530","raw_type":"contributionToPeriodical"},{"id":"pmh:oai:pure.atira.dk:publications/e6693fb0-53df-450b-a7a1-19df2fefa9e4","is_oa":false,"landing_page_url":"https://vbn.aau.dk/da/publications/e6693fb0-53df-450b-a7a1-19df2fefa9e4","pdf_url":null,"source":{"id":"https://openalex.org/S4306401731","display_name":"VBN Forskningsportal (Aalborg Universitet)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I891191580","host_organization_name":"Aalborg University","host_organization_lineage":["https://openalex.org/I891191580"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Shakibfar, S, Yazdchi, M & Hosseinabadi, S A 2019, Effectiveness of CRT-D Versus ICD on Prevention of Electrical Storm: Big Data from the USA. in 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)., 8857530, IEEE (Institute of Electrical and Electronics Engineers), I E E E Engineering in Medicine and Biology Society. Conference Proceedings, pp. 302-304, Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC, Berlin, Berlin, Germany, 23/07/2019. https://doi.org/10.1109/EMBC.2019.8857530","raw_type":"info:eu-repo/semantics/publishedVersion"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","display_name":"Good health and well-being","score":0.8199999928474426}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":31,"referenced_works":["https://openalex.org/W143811580","https://openalex.org/W1493462064","https://openalex.org/W1707095901","https://openalex.org/W1965355671","https://openalex.org/W1985277411","https://openalex.org/W1990047966","https://openalex.org/W2008171456","https://openalex.org/W2012574332","https://openalex.org/W2031905482","https://openalex.org/W2048096952","https://openalex.org/W2056516935","https://openalex.org/W2098199242","https://openalex.org/W2105447112","https://openalex.org/W2108062940","https://openalex.org/W2113062592","https://openalex.org/W2149933505","https://openalex.org/W2155544947","https://openalex.org/W2161984704","https://openalex.org/W2166047934","https://openalex.org/W2172079680","https://openalex.org/W2397911846","https://openalex.org/W2401853487","https://openalex.org/W2427094903","https://openalex.org/W2549085036","https://openalex.org/W2553795991","https://openalex.org/W2902748974","https://openalex.org/W3023400402","https://openalex.org/W3147811369","https://openalex.org/W3193516025","https://openalex.org/W6629395431","https://openalex.org/W6756155558"],"related_works":["https://openalex.org/W2111887156","https://openalex.org/W2051061635","https://openalex.org/W2594890226","https://openalex.org/W4220884743","https://openalex.org/W2013162077","https://openalex.org/W4409738838","https://openalex.org/W2592912933","https://openalex.org/W2740060271","https://openalex.org/W2141214479","https://openalex.org/W2604199795"],"abstract_inverted_index":{"Patients":[0],"with":[1,15,25,56,85,129,140,171,182],"implantable":[2],"cardioverter-defibrillator":[3],"(ICD)":[4],"are":[5],"at":[6,97],"the":[7,37,52,135,141,149],"risk":[8,158,180],"of":[9,20,39,143],"electrical":[10],"storm":[11],"(ES)":[12],"occurrence":[13],"associated":[14,55],"mortality":[16],"and":[17,76,101,117,166],"poor":[18],"quality":[19],"life.":[21],"Cardiac":[22],"resynchronization":[23],"therapy":[24,90],"defibrillator":[26],"(CRT-D)":[27],"minimizes":[28],"inappropriate":[29],"ICD":[30,43,126,186],"shocks.":[31],"However,":[32],"limited":[33],"reports":[34],"exist":[35],"on":[36,44,64],"impact":[38],"CRT-D":[40,105,174],"versus":[41],"traditional":[42,185],"ES":[45,57,100,119,137,160,179],"occurrences":[46,161],"in":[47,59,73,110,159],"real-life":[48],"cohorts.":[49],"We":[50],"evaluated":[51],"implanted-device":[53],"characteristics":[54],"events":[58,120],"a":[60],"large":[61],"data":[62,72],"based":[63],"daily":[65],"stored":[66],"device-summaries":[67],"obtained":[68],"from":[69],"remote":[70],"monitoring":[71],"US.Between":[74],"2004":[75],"2016,":[77],"19,935":[78],"US":[79],"patients":[80,94,113,147,183],"were":[81,91,108,123],"implanted.":[82],"Survival":[83],"analyses":[84,153],"Cox":[86,151],"regression":[87,152],"for":[88,145],"device-shock":[89],"performed":[92],"between":[93],"who":[95],"experienced":[96],"least":[98],"one":[99],"those":[102],"without":[103],"ES.":[104],"devices":[106],"(bi-ventricular)":[107],"implanted":[109,128],"5522":[111],"(28%)":[112],"during":[114,148],"this":[115],"period,":[116],"their":[118],"over":[121],"time":[122],"compared":[124],"to":[125,177],"recipients":[127],"RV":[130],"lead.":[131],"Primary":[132],"endpoint":[133],"was":[134],"first":[136],"event.ES":[138],"occurred":[139],"rate":[142],"7.26%":[144],"all":[146],"period.":[150],"revealed":[154],"significantly":[155],"an":[156],"increase":[157],"(the":[162],"p-value":[163],"<;":[164],"0.05":[165],"hazard":[167],"ratio":[168],">>":[169],"1)":[170],"shock":[172],"therapy.":[173],"implant":[175],"led":[176],"lower":[178],"comparing":[181],"received":[184],"(RV":[187],"only).":[188]},"counts_by_year":[],"updated_date":"2026-03-16T09:10:04.655348","created_date":"2019-10-18T00:00:00"}
