{"id":"https://openalex.org/W2899122820","doi":"https://doi.org/10.1109/embc.2018.8513054","title":"The Calibration Method for Blood Pressure Pulse Wave Measurement Based on Arterial Tonometry Method","display_name":"The Calibration Method for Blood Pressure Pulse Wave Measurement Based on Arterial Tonometry Method","publication_year":2018,"publication_date":"2018-07-01","ids":{"openalex":"https://openalex.org/W2899122820","doi":"https://doi.org/10.1109/embc.2018.8513054","mag":"2899122820","pmid":"https://pubmed.ncbi.nlm.nih.gov/30440291"},"language":"en","primary_location":{"id":"doi:10.1109/embc.2018.8513054","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2018.8513054","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5032608291","display_name":"Koichi Shimura","orcid":null},"institutions":[{"id":"https://openalex.org/I96679780","display_name":"Chuo University","ror":"https://ror.org/03qvqb743","country_code":"JP","type":"education","lineage":["https://openalex.org/I96679780"]}],"countries":["JP"],"is_corresponding":true,"raw_author_name":"Koichi Shimura","raw_affiliation_strings":["Chuo Daigaku, Hachioji, Tokyo, JP"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Chuo Daigaku, Hachioji, Tokyo, JP","institution_ids":["https://openalex.org/I96679780"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5112639336","display_name":"Masataka Hori","orcid":null},"institutions":[{"id":"https://openalex.org/I96679780","display_name":"Chuo University","ror":"https://ror.org/03qvqb743","country_code":"JP","type":"education","lineage":["https://openalex.org/I96679780"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Masataka Hori","raw_affiliation_strings":["Chuo Daigaku, Hachioji, Tokyo, JP"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Chuo Daigaku, Hachioji, Tokyo, JP","institution_ids":["https://openalex.org/I96679780"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101036339","display_name":"Tetsuji DOHI","orcid":null},"institutions":[{"id":"https://openalex.org/I96679780","display_name":"Chuo University","ror":"https://ror.org/03qvqb743","country_code":"JP","type":"education","lineage":["https://openalex.org/I96679780"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Tetsuji Dohi","raw_affiliation_strings":["Chuo Daigaku, Hachioji, Tokyo, JP"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Chuo Daigaku, Hachioji, Tokyo, JP","institution_ids":["https://openalex.org/I96679780"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5069564994","display_name":"Hiroyuki Takao","orcid":"https://orcid.org/0000-0002-9285-9642"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Hiroyuki Takao","raw_affiliation_strings":["Gakko Hojin Jikei Daigaku, Minato-ku, Tokyo, JP"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Gakko Hojin Jikei Daigaku, Minato-ku, Tokyo, JP","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5032608291"],"corresponding_institution_ids":["https://openalex.org/I96679780"],"apc_list":null,"apc_paid":null,"fwci":0.1743,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.59487766,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":95},"biblio":{"volume":"2018","issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.9973999857902527,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.9973999857902527,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9958999752998352,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10924","display_name":"Cardiovascular Health and Disease Prevention","score":0.9929999709129333,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.726493239402771},{"id":"https://openalex.org/keywords/pressure-measurement","display_name":"Pressure measurement","score":0.6922140121459961},{"id":"https://openalex.org/keywords/blood-pressure","display_name":"Blood pressure","score":0.6557770371437073},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.600247859954834},{"id":"https://openalex.org/keywords/photoplethysmogram","display_name":"Photoplethysmogram","score":0.5217562317848206},{"id":"https://openalex.org/keywords/pulse","display_name":"Pulse (music)","score":0.45276394486427307},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.4310321509838104},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.411997526884079},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.24251684546470642},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.23935836553573608},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.20097267627716064},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.195749431848526},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.18814852833747864},{"id":"https://openalex.org/keywords/internal-medicine","display_name":"Internal medicine","score":0.10638678073883057},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.08141151070594788}],"concepts":[{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.726493239402771},{"id":"https://openalex.org/C80264047","wikidata":"https://www.wikidata.org/wiki/Q7424019","display_name":"Pressure measurement","level":2,"score":0.6922140121459961},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.6557770371437073},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.600247859954834},{"id":"https://openalex.org/C116390426","wikidata":"https://www.wikidata.org/wiki/Q7187885","display_name":"Photoplethysmogram","level":3,"score":0.5217562317848206},{"id":"https://openalex.org/C2780167933","wikidata":"https://www.wikidata.org/wiki/Q1550652","display_name":"Pulse (music)","level":3,"score":0.45276394486427307},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.4310321509838104},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.411997526884079},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.24251684546470642},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.23935836553573608},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.20097267627716064},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.195749431848526},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.18814852833747864},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.10638678073883057},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.08141151070594788},{"id":"https://openalex.org/C94915269","wikidata":"https://www.wikidata.org/wiki/Q1834857","display_name":"Detector","level":2,"score":0.0},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.0},{"id":"https://openalex.org/C106131492","wikidata":"https://www.wikidata.org/wiki/Q3072260","display_name":"Filter (signal processing)","level":2,"score":0.0},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D001158","descriptor_name":"Arteries","qualifier_ui":"Q000503","qualifier_name":"physiopathology","is_major_topic":false},{"descriptor_ui":"D001158","descriptor_name":"Arteries","qualifier_ui":"Q000503","qualifier_name":"physiopathology","is_major_topic":false},{"descriptor_ui":"D001158","descriptor_name":"Arteries","qualifier_ui":"Q000503","qualifier_name":"physiopathology","is_major_topic":false},{"descriptor_ui":"D001794","descriptor_name":"Blood Pressure","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D001794","descriptor_name":"Blood Pressure","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D001794","descriptor_name":"Blood Pressure","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008297","descriptor_name":"Male","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008297","descriptor_name":"Male","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008297","descriptor_name":"Male","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008365","descriptor_name":"Manometry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008365","descriptor_name":"Manometry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008365","descriptor_name":"Manometry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008365","descriptor_name":"Manometry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D008365","descriptor_name":"Manometry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D008365","descriptor_name":"Manometry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D055815","descriptor_name":"Young Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D055815","descriptor_name":"Young Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D055815","descriptor_name":"Young Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/embc.2018.8513054","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2018.8513054","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},{"id":"pmid:30440291","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/30440291","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","score":0.6200000047683716,"display_name":"Good health and well-being"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W2005473461","https://openalex.org/W2034993730","https://openalex.org/W2057233709","https://openalex.org/W2115301962"],"related_works":["https://openalex.org/W4297152434","https://openalex.org/W2732360296","https://openalex.org/W2384584038","https://openalex.org/W2043326433","https://openalex.org/W2777534421","https://openalex.org/W2067862553","https://openalex.org/W2428313263","https://openalex.org/W3040886831","https://openalex.org/W2368317148","https://openalex.org/W2745302425"],"abstract_inverted_index":{"In":[0],"this":[1,49],"study,":[2],"we":[3],"report":[4],"a":[5,14,42,89,132],"method":[6,27,40,116],"to":[7,28,77,120,126],"accurately":[8,121],"calibrate":[9,122],"the":[10,24,37,54,65,70,79,82,85,91,97,101,104,114,123],"forces":[11,125],"measured":[12,59,124],"by":[13,23],"wearable":[15],"device":[16,34,68],"for":[17,48],"measuring":[18],"blood":[19,30,55,105,128],"pressure":[20,31,56,106,129],"pulse":[21],"waves":[22],"arterial":[25,38,66],"tonometry":[26,39,67],"obtain":[29,127],"measurements.":[32],"A":[33],"based":[35],"on":[36],"and":[41,53,69,103],"commercially":[43],"available":[44],"manometer":[45],"was":[46,75,107,111],"used":[47,119],"research.":[50],"The":[51,72],"force":[52,102],"were":[57],"simultaneously":[58],"at":[60],"three":[61],"measurement":[62],"heights":[63],"using":[64],"manometer.":[71],"proposed":[73,115],"calibration":[74],"found":[76],"reduce":[78],"influence":[80],"of":[81,84,94,96,135],"inclination":[83],"lower":[86],"arm.":[87],"As":[88],"result,":[90],"average":[92],"coefficient":[93,134],"determination":[95],"regression":[98],"equations":[99],"between":[100],"0.96.":[108],"Thus,":[109],"it":[110],"concluded":[112],"that":[113],"can":[117],"be":[118],"measurements":[130],"with":[131],"high":[133],"determination.":[136]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2019,"cited_by_count":1}],"updated_date":"2026-05-10T08:33:47.465468","created_date":"2025-10-10T00:00:00"}