{"id":"https://openalex.org/W2756270872","doi":"https://doi.org/10.1109/embc.2017.8037795","title":"A new 4-DOF parallel robot for MRI-guided percutaneous interventions: Kinematic analysis","display_name":"A new 4-DOF parallel robot for MRI-guided percutaneous interventions: Kinematic analysis","publication_year":2017,"publication_date":"2017-07-01","ids":{"openalex":"https://openalex.org/W2756270872","doi":"https://doi.org/10.1109/embc.2017.8037795","mag":"2756270872","pmid":"https://pubmed.ncbi.nlm.nih.gov/29060836"},"language":"en","primary_location":{"id":"doi:10.1109/embc.2017.8037795","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2017.8037795","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5015341073","display_name":"Jin Seob Kim","orcid":"https://orcid.org/0000-0001-5091-2014"},"institutions":[{"id":"https://openalex.org/I145311948","display_name":"Johns Hopkins University","ror":"https://ror.org/00za53h95","country_code":"US","type":"education","lineage":["https://openalex.org/I145311948"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Jin Seob Kim","raw_affiliation_strings":["Johns Hopkins University, Baltimore, MD, US"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Johns Hopkins University, Baltimore, MD, US","institution_ids":["https://openalex.org/I145311948"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5112574483","display_name":"David Levi","orcid":null},"institutions":[{"id":"https://openalex.org/I145311948","display_name":"Johns Hopkins University","ror":"https://ror.org/00za53h95","country_code":"US","type":"education","lineage":["https://openalex.org/I145311948"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"David Levi","raw_affiliation_strings":["Johns Hopkins University, Baltimore, MD, US"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Johns Hopkins University, Baltimore, MD, US","institution_ids":["https://openalex.org/I145311948"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5024536966","display_name":"Reza Monfaredi","orcid":"https://orcid.org/0000-0003-1507-8137"},"institutions":[{"id":"https://openalex.org/I1336742384","display_name":"Children's National","ror":"https://ror.org/03wa2q724","country_code":"US","type":"healthcare","lineage":["https://openalex.org/I1336742384"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Reza Monfaredi","raw_affiliation_strings":["Childrens National Health System, Sheikh Zayed Institute for Pediatric Surgical Innovation, DC, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Childrens National Health System, Sheikh Zayed Institute for Pediatric Surgical Innovation, DC, USA","institution_ids":["https://openalex.org/I1336742384"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5025749015","display_name":"Kevin Cleary","orcid":"https://orcid.org/0000-0001-9809-4823"},"institutions":[{"id":"https://openalex.org/I1336742384","display_name":"Children's National","ror":"https://ror.org/03wa2q724","country_code":"US","type":"healthcare","lineage":["https://openalex.org/I1336742384"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Kevin Cleary","raw_affiliation_strings":["Childrens National Health System, Sheikh Zayed Institute for Pediatric Surgical Innovation, DC, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Childrens National Health System, Sheikh Zayed Institute for Pediatric Surgical Innovation, DC, USA","institution_ids":["https://openalex.org/I1336742384"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5063913520","display_name":"Iulian Iordachita","orcid":"https://orcid.org/0000-0002-2510-9008"},"institutions":[{"id":"https://openalex.org/I145311948","display_name":"Johns Hopkins University","ror":"https://ror.org/00za53h95","country_code":"US","type":"education","lineage":["https://openalex.org/I145311948"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Iulian Iordachita","raw_affiliation_strings":["Johns Hopkins University, Baltimore, MD, US"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Johns Hopkins University, Baltimore, MD, US","institution_ids":["https://openalex.org/I145311948"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.0187,"has_fulltext":false,"cited_by_count":9,"citation_normalized_percentile":{"value":0.85413622,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":"2017","issue":null,"first_page":"4251","last_page":"4255"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10868","display_name":"Soft Robotics and Applications","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10868","display_name":"Soft Robotics and Applications","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11984","display_name":"Anatomy and Medical Technology","score":0.987500011920929,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10378","display_name":"Advanced MRI Techniques and Applications","score":0.9768000245094299,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/kinematics","display_name":"Kinematics","score":0.8251362442970276},{"id":"https://openalex.org/keywords/robot","display_name":"Robot","score":0.7564127445220947},{"id":"https://openalex.org/keywords/percutaneous","display_name":"Percutaneous","score":0.7022072672843933},{"id":"https://openalex.org/keywords/rigidity","display_name":"Rigidity (electromagnetism)","score":0.6166605949401855},{"id":"https://openalex.org/keywords/robot-kinematics","display_name":"Robot kinematics","score":0.5918227434158325},{"id":"https://openalex.org/keywords/parallel-manipulator","display_name":"Parallel manipulator","score":0.5798172950744629},{"id":"https://openalex.org/keywords/robot-calibration","display_name":"Robot calibration","score":0.5123339891433716},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.49573788046836853},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.4774121046066284},{"id":"https://openalex.org/keywords/inertial-frame-of-reference","display_name":"Inertial frame of reference","score":0.41506487131118774},{"id":"https://openalex.org/keywords/computer-vision","display_name":"Computer vision","score":0.4003772735595703},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.3496834635734558},{"id":"https://openalex.org/keywords/mobile-robot","display_name":"Mobile robot","score":0.2588271498680115},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.23819509148597717},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.1656918227672577},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.1479288637638092},{"id":"https://openalex.org/keywords/surgery","display_name":"Surgery","score":0.1244935691356659},{"id":"https://openalex.org/keywords/structural-engineering","display_name":"Structural engineering","score":0.07792308926582336}],"concepts":[{"id":"https://openalex.org/C39920418","wikidata":"https://www.wikidata.org/wiki/Q11476","display_name":"Kinematics","level":2,"score":0.8251362442970276},{"id":"https://openalex.org/C90509273","wikidata":"https://www.wikidata.org/wiki/Q11012","display_name":"Robot","level":2,"score":0.7564127445220947},{"id":"https://openalex.org/C2780813298","wikidata":"https://www.wikidata.org/wiki/Q2071287","display_name":"Percutaneous","level":2,"score":0.7022072672843933},{"id":"https://openalex.org/C160343418","wikidata":"https://www.wikidata.org/wiki/Q185256","display_name":"Rigidity (electromagnetism)","level":2,"score":0.6166605949401855},{"id":"https://openalex.org/C74222875","wikidata":"https://www.wikidata.org/wiki/Q16000312","display_name":"Robot kinematics","level":4,"score":0.5918227434158325},{"id":"https://openalex.org/C138094506","wikidata":"https://www.wikidata.org/wiki/Q12065277","display_name":"Parallel manipulator","level":3,"score":0.5798172950744629},{"id":"https://openalex.org/C192299074","wikidata":"https://www.wikidata.org/wiki/Q2160034","display_name":"Robot calibration","level":5,"score":0.5123339891433716},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.49573788046836853},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.4774121046066284},{"id":"https://openalex.org/C173386949","wikidata":"https://www.wikidata.org/wiki/Q192735","display_name":"Inertial frame of reference","level":2,"score":0.41506487131118774},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.4003772735595703},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.3496834635734558},{"id":"https://openalex.org/C19966478","wikidata":"https://www.wikidata.org/wiki/Q4810574","display_name":"Mobile robot","level":3,"score":0.2588271498680115},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.23819509148597717},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1656918227672577},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.1479288637638092},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.1244935691356659},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.07792308926582336},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C74650414","wikidata":"https://www.wikidata.org/wiki/Q11397","display_name":"Classical mechanics","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D001696","descriptor_name":"Biomechanical Phenomena","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001696","descriptor_name":"Biomechanical Phenomena","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001696","descriptor_name":"Biomechanical Phenomena","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008279","descriptor_name":"Magnetic Resonance Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D008279","descriptor_name":"Magnetic Resonance Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D008279","descriptor_name":"Magnetic Resonance Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D012371","descriptor_name":"Robotics","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012371","descriptor_name":"Robotics","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012371","descriptor_name":"Robotics","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019047","descriptor_name":"Phantoms, Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019047","descriptor_name":"Phantoms, Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019047","descriptor_name":"Phantoms, Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D065287","descriptor_name":"Robotic Surgical Procedures","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D065287","descriptor_name":"Robotic Surgical Procedures","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D065287","descriptor_name":"Robotic Surgical Procedures","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/embc.2017.8037795","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2017.8037795","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},{"id":"pmid:29060836","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/29060836","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W1874036279","https://openalex.org/W1974799242","https://openalex.org/W1981822312","https://openalex.org/W1998299095","https://openalex.org/W1998868250","https://openalex.org/W2068821878","https://openalex.org/W2104310497","https://openalex.org/W2129310538","https://openalex.org/W2142332302","https://openalex.org/W2150569243","https://openalex.org/W2155672172","https://openalex.org/W2161368485","https://openalex.org/W2294821011","https://openalex.org/W2401275988","https://openalex.org/W6643955894","https://openalex.org/W6645725200"],"related_works":["https://openalex.org/W2737577120","https://openalex.org/W4205370188","https://openalex.org/W2158374453","https://openalex.org/W2157600580","https://openalex.org/W2771857660","https://openalex.org/W2792156965","https://openalex.org/W2097303437","https://openalex.org/W1879261740","https://openalex.org/W2169324687","https://openalex.org/W2891426942"],"abstract_inverted_index":{"In":[0],"this":[1],"paper,":[2],"we":[3,41],"present":[4,42],"the":[5,21,43,46,55,71,80],"concept":[6,44],"of":[7,23,45,57,73],"a":[8,38],"novel":[9],"4-DOF":[10],"parallel":[11,28],"robot":[12,47,53],"for":[13],"MRI-guided":[14],"percutaneous":[15],"interventions.":[16],"This":[17,52],"system":[18],"belongs":[19],"to":[20,65],"class":[22],"patient-mounted":[24],"robots,":[25],"with":[26],"two":[27,33],"circular":[29],"stages":[30],"along":[31],"which":[32,76],"actuating":[34],"joints":[35],"move.":[36],"As":[37],"first":[39],"step,":[40],"and":[48,60],"its":[49,66],"kinematic":[50],"analysis.":[51],"has":[54],"potential":[56],"increased":[58],"rigidity":[59],"reduced":[61],"inertial":[62],"effect":[63],"compared":[64],"predecessor.":[67],"It":[68],"also":[69],"minimizes":[70],"number":[72],"moving":[74],"components,":[75],"enhances":[77],"safety":[78],"during":[79],"robot's":[81],"operation.":[82]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":3},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":2}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
