{"id":"https://openalex.org/W2756465870","doi":"https://doi.org/10.1109/embc.2017.8036834","title":"Imaging of regional air distributions in porcine lungs using high-performance electrical impedance tomography system","display_name":"Imaging of regional air distributions in porcine lungs using high-performance electrical impedance tomography system","publication_year":2017,"publication_date":"2017-07-01","ids":{"openalex":"https://openalex.org/W2756465870","doi":"https://doi.org/10.1109/embc.2017.8036834","mag":"2756465870","pmid":"https://pubmed.ncbi.nlm.nih.gov/29059882"},"language":"en","primary_location":{"id":"doi:10.1109/embc.2017.8036834","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2017.8036834","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5064130094","display_name":"Geuk Young Jang","orcid":"https://orcid.org/0000-0002-4960-1718"},"institutions":[{"id":"https://openalex.org/I35928602","display_name":"Kyung Hee University","ror":"https://ror.org/01zqcg218","country_code":"KR","type":"education","lineage":["https://openalex.org/I35928602"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"G.Y. Jang","raw_affiliation_strings":["Department of Biomedical Engineering, Kyung Hee University, Yongin-si, Gyeonggi-do, Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Biomedical Engineering, Kyung Hee University, Yongin-si, Gyeonggi-do, Korea","institution_ids":["https://openalex.org/I35928602"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5027181934","display_name":"Y.B. Kim","orcid":null},"institutions":[{"id":"https://openalex.org/I4210112503","display_name":"Kyung Hee University Medical Center","ror":"https://ror.org/01vbmek33","country_code":"KR","type":"healthcare","lineage":["https://openalex.org/I35928602","https://openalex.org/I4210112503","https://openalex.org/I4405258385"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Y.B. Kim","raw_affiliation_strings":["Department of Medical Engineering, Kyung Hee University, Seoul, Republic of Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Medical Engineering, Kyung Hee University, Seoul, Republic of Korea","institution_ids":["https://openalex.org/I4210112503"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5082680415","display_name":"Hun Wi","orcid":"https://orcid.org/0000-0001-8424-7593"},"institutions":[{"id":"https://openalex.org/I35928602","display_name":"Kyung Hee University","ror":"https://ror.org/01zqcg218","country_code":"KR","type":"education","lineage":["https://openalex.org/I35928602"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"H. Wi","raw_affiliation_strings":["Department of Biomedical Engineering, Kyung Hee University, Seoul, Republic of Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Biomedical Engineering, Kyung Hee University, Seoul, Republic of Korea","institution_ids":["https://openalex.org/I35928602"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5069125676","display_name":"T.I. Oh","orcid":"https://orcid.org/0000-0003-3820-0107"},"institutions":[{"id":"https://openalex.org/I35928602","display_name":"Kyung Hee University","ror":"https://ror.org/01zqcg218","country_code":"KR","type":"education","lineage":["https://openalex.org/I35928602"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"T.I. Oh","raw_affiliation_strings":["Department of Biomedical Engineering, Kyung Hee University, Seoul, Republic of Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Biomedical Engineering, Kyung Hee University, Seoul, Republic of Korea","institution_ids":["https://openalex.org/I35928602"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5017541279","display_name":"Chi Ryang Chung","orcid":"https://orcid.org/0000-0003-1830-307X"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"C.R. Chung","raw_affiliation_strings":["Department of Critical Care Medicine, School of Medicine, Seoul, Republic of Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Critical Care Medicine, School of Medicine, Seoul, Republic of Korea","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5084299817","display_name":"Gee Young Suh","orcid":"https://orcid.org/0000-0001-5473-1712"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"G.Y. Suh","raw_affiliation_strings":["Department of Critical Care Medicine, School of Medicine, Seoul, Republic of Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Critical Care Medicine, School of Medicine, Seoul, Republic of Korea","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5020584084","display_name":"Eung Je Woo","orcid":"https://orcid.org/0000-0001-5100-6945"},"institutions":[{"id":"https://openalex.org/I35928602","display_name":"Kyung Hee University","ror":"https://ror.org/01zqcg218","country_code":"KR","type":"education","lineage":["https://openalex.org/I35928602"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"E.J. Woo","raw_affiliation_strings":["Department of Biomedical Engineering, Kyung Hee University, Seoul, Republic of Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Biomedical Engineering, Kyung Hee University, Seoul, Republic of Korea","institution_ids":["https://openalex.org/I35928602"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":7,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.1462,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.5214401,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":"2017","issue":null,"first_page":"349","last_page":"351"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":0.9976999759674072,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":0.9976999759674072,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10322","display_name":"Respiratory Support and Mechanisms","score":0.9954000115394592,"subfield":{"id":"https://openalex.org/subfields/2740","display_name":"Pulmonary and Respiratory Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9865000247955322,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electrical-impedance-tomography","display_name":"Electrical impedance tomography","score":0.946186363697052},{"id":"https://openalex.org/keywords/ventilation","display_name":"Ventilation (architecture)","score":0.6589627265930176},{"id":"https://openalex.org/keywords/tomography","display_name":"Tomography","score":0.5684293508529663},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.5605921149253845},{"id":"https://openalex.org/keywords/lung","display_name":"Lung","score":0.5451818704605103},{"id":"https://openalex.org/keywords/lung-ventilation","display_name":"Lung ventilation","score":0.5368064045906067},{"id":"https://openalex.org/keywords/mechanical-ventilation","display_name":"Mechanical ventilation","score":0.5212855339050293},{"id":"https://openalex.org/keywords/pulmonary-compliance","display_name":"Pulmonary compliance","score":0.4329873025417328},{"id":"https://openalex.org/keywords/positive-end-expiratory-pressure","display_name":"Positive end-expiratory pressure","score":0.41854581236839294},{"id":"https://openalex.org/keywords/in-vivo","display_name":"In vivo","score":0.4133192002773285},{"id":"https://openalex.org/keywords/continuous-monitoring","display_name":"Continuous monitoring","score":0.41178569197654724},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.3691987097263336},{"id":"https://openalex.org/keywords/radiology","display_name":"Radiology","score":0.2760865092277527},{"id":"https://openalex.org/keywords/anesthesia","display_name":"Anesthesia","score":0.10751575231552124},{"id":"https://openalex.org/keywords/internal-medicine","display_name":"Internal medicine","score":0.10558611154556274},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.10556849837303162},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.05791598558425903}],"concepts":[{"id":"https://openalex.org/C155175808","wikidata":"https://www.wikidata.org/wiki/Q1326472","display_name":"Electrical impedance tomography","level":3,"score":0.946186363697052},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.6589627265930176},{"id":"https://openalex.org/C163716698","wikidata":"https://www.wikidata.org/wiki/Q841267","display_name":"Tomography","level":2,"score":0.5684293508529663},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.5605921149253845},{"id":"https://openalex.org/C2777714996","wikidata":"https://www.wikidata.org/wiki/Q7886","display_name":"Lung","level":2,"score":0.5451818704605103},{"id":"https://openalex.org/C2987681997","wikidata":"https://www.wikidata.org/wiki/Q9530","display_name":"Lung ventilation","level":3,"score":0.5368064045906067},{"id":"https://openalex.org/C2777080012","wikidata":"https://www.wikidata.org/wiki/Q3766250","display_name":"Mechanical ventilation","level":2,"score":0.5212855339050293},{"id":"https://openalex.org/C136936797","wikidata":"https://www.wikidata.org/wiki/Q2990558","display_name":"Pulmonary compliance","level":3,"score":0.4329873025417328},{"id":"https://openalex.org/C2778917391","wikidata":"https://www.wikidata.org/wiki/Q352381","display_name":"Positive end-expiratory pressure","level":3,"score":0.41854581236839294},{"id":"https://openalex.org/C207001950","wikidata":"https://www.wikidata.org/wiki/Q141124","display_name":"In vivo","level":2,"score":0.4133192002773285},{"id":"https://openalex.org/C2776902269","wikidata":"https://www.wikidata.org/wiki/Q5165493","display_name":"Continuous monitoring","level":2,"score":0.41178569197654724},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.3691987097263336},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.2760865092277527},{"id":"https://openalex.org/C42219234","wikidata":"https://www.wikidata.org/wiki/Q131130","display_name":"Anesthesia","level":1,"score":0.10751575231552124},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.10558611154556274},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.10556849837303162},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.05791598558425903},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.0},{"id":"https://openalex.org/C150903083","wikidata":"https://www.wikidata.org/wiki/Q7108","display_name":"Biotechnology","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D000818","descriptor_name":"Animals","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000818","descriptor_name":"Animals","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000818","descriptor_name":"Animals","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008168","descriptor_name":"Lung","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D008168","descriptor_name":"Lung","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D008168","descriptor_name":"Lung","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D011175","descriptor_name":"Positive-Pressure Respiration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011175","descriptor_name":"Positive-Pressure Respiration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011175","descriptor_name":"Positive-Pressure Respiration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013552","descriptor_name":"Swine","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013552","descriptor_name":"Swine","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013552","descriptor_name":"Swine","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013990","descriptor_name":"Tidal Volume","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013990","descriptor_name":"Tidal Volume","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013990","descriptor_name":"Tidal Volume","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014054","descriptor_name":"Tomography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014054","descriptor_name":"Tomography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014054","descriptor_name":"Tomography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/embc.2017.8036834","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2017.8036834","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},{"id":"pmid:29059882","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/29059882","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W113375528","https://openalex.org/W1551644454","https://openalex.org/W1976631627","https://openalex.org/W1982338176","https://openalex.org/W1982395649","https://openalex.org/W1992681652","https://openalex.org/W1995325863","https://openalex.org/W1995443190","https://openalex.org/W2039534575","https://openalex.org/W2089871326","https://openalex.org/W2143748013","https://openalex.org/W2509431176","https://openalex.org/W6725759983"],"related_works":["https://openalex.org/W2031656606","https://openalex.org/W4296725798","https://openalex.org/W2032203301","https://openalex.org/W4213047795","https://openalex.org/W4233371539","https://openalex.org/W1998949139","https://openalex.org/W2231312684","https://openalex.org/W2083117109","https://openalex.org/W4254805208","https://openalex.org/W2466499308"],"abstract_inverted_index":{"Electrical":[0],"impedance":[1],"tomography":[2],"(EIT)":[3],"allows":[4],"functional":[5],"imaging":[6,45],"of":[7,15,22,47,61,73],"regional":[8,23,48,93],"lung":[9,35,49],"ventilation":[10,50],"for":[11,34,117],"real-time":[12],"bedside":[13],"monitoring":[14,115],"mechanically":[16],"ventilated":[17],"patients.":[18],"Images":[19],"showing":[20],"time-changes":[21],"air":[24],"distributions":[25],"in":[26,42,104],"the":[27,77,81,86,110],"lungs":[28],"can":[29],"provide":[30],"valuable":[31],"diagnostic":[32],"information":[33,84],"protective":[36,120],"mechanical":[37,67,87],"ventilation.":[38],"This":[39],"paper":[40],"reports":[41],"vivo":[43,105],"porcine":[44],"experiments":[46],"using":[51],"a":[52,70,113],"16-channel":[53],"parallel":[54],"EIT":[55],"system.":[56],"Real-time":[57],"time-difference":[58],"chest":[59],"images":[60,78,95],"10":[62],"animals":[63],"were":[64],"reconstructed":[65],"during":[66],"ventilations":[68],"with":[69,80],"temporal":[71],"resolution":[72],"50":[74],"frame/s.":[75],"Analyzing":[76],"together":[79],"airway":[82],"volume-pressure":[83],"from":[85],"ventilator,":[88],"we":[89,108],"could":[90],"successfully":[91],"produce":[92],"compliance":[94],"at":[96],"PEEP":[97],"(positive":[98],"end":[99],"expiratory":[100],"pressure)":[101],"titration.":[102],"From":[103],"animal":[106],"experiments,":[107],"propose":[109],"method":[111],"as":[112],"continuous":[114],"means":[116],"LPV":[118],"(lung":[119],"ventilation).":[121]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2017,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}