{"id":"https://openalex.org/W2532284183","doi":"https://doi.org/10.1109/embc.2016.7592215","title":"An autoclavable wireless palpation instrument for minimally invasive surgery","display_name":"An autoclavable wireless palpation instrument for minimally invasive surgery","publication_year":2016,"publication_date":"2016-08-01","ids":{"openalex":"https://openalex.org/W2532284183","doi":"https://doi.org/10.1109/embc.2016.7592215","mag":"2532284183","pmid":"https://pubmed.ncbi.nlm.nih.gov/28269733"},"language":"en","primary_location":{"id":"doi:10.1109/embc.2016.7592215","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2016.7592215","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5076980800","display_name":"Anish S. Naidu","orcid":"https://orcid.org/0000-0001-9494-929X"},"institutions":[{"id":"https://openalex.org/I131944076","display_name":"Lawson Health Research Institute","ror":"https://ror.org/051gsh239","country_code":"CA","type":"healthcare","lineage":["https://openalex.org/I131944076"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Anish S. Naidu","raw_affiliation_strings":["Canadian Surgical Technologies and Advanced Robotics (CSTAR), Lawson Health Research Institute, London, ON, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Canadian Surgical Technologies and Advanced Robotics (CSTAR), Lawson Health Research Institute, London, ON, Canada","institution_ids":["https://openalex.org/I131944076"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5025893997","display_name":"Abelardo Escoto","orcid":null},"institutions":[{"id":"https://openalex.org/I131944076","display_name":"Lawson Health Research Institute","ror":"https://ror.org/051gsh239","country_code":"CA","type":"healthcare","lineage":["https://openalex.org/I131944076"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Abelardo Escoto","raw_affiliation_strings":["Canadian Surgical Technologies and Advanced Robotics (CSTAR), Lawson Health Research Institute, London, ON, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Canadian Surgical Technologies and Advanced Robotics (CSTAR), Lawson Health Research Institute, London, ON, Canada","institution_ids":["https://openalex.org/I131944076"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5048148064","display_name":"Omar Fahmy","orcid":"https://orcid.org/0000-0002-1631-2733"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Omar Fahmy","raw_affiliation_strings":["CSTAR"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"CSTAR","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5032056508","display_name":"Rajni V. Patel","orcid":"https://orcid.org/0000-0003-3431-4617"},"institutions":[{"id":"https://openalex.org/I125749732","display_name":"Western University","ror":"https://ror.org/02grkyz14","country_code":"CA","type":"education","lineage":["https://openalex.org/I125749732"]},{"id":"https://openalex.org/I131944076","display_name":"Lawson Health Research Institute","ror":"https://ror.org/051gsh239","country_code":"CA","type":"healthcare","lineage":["https://openalex.org/I131944076"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Rajni V. Patel","raw_affiliation_strings":["Canadian Surgical Technologies and Advanced Robotics (CSTAR), Lawson Health Research Institute, London, ON, Canada","Department of Electrical and Computer Engineering, Western University, London, ON, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Canadian Surgical Technologies and Advanced Robotics (CSTAR), Lawson Health Research Institute, London, ON, Canada","institution_ids":["https://openalex.org/I131944076"]},{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Western University, London, ON, Canada","institution_ids":["https://openalex.org/I125749732"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5039782206","display_name":"Michael D. Naish","orcid":"https://orcid.org/0000-0001-7603-7182"},"institutions":[{"id":"https://openalex.org/I131944076","display_name":"Lawson Health Research Institute","ror":"https://ror.org/051gsh239","country_code":"CA","type":"healthcare","lineage":["https://openalex.org/I131944076"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Michael D. Naish","raw_affiliation_strings":["Canadian Surgical Technologies and Advanced Robotics (CSTAR), Lawson Health Research Institute, London, ON, Canada","Department of Electrical and Computer Engineering and the Department of Mechanical and Materials Engineering, The experimental procedures involving human subjects described herein were approved by the University's Research Ethics Board"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Canadian Surgical Technologies and Advanced Robotics (CSTAR), Lawson Health Research Institute, London, ON, Canada","institution_ids":["https://openalex.org/I131944076"]},{"raw_affiliation_string":"Department of Electrical and Computer Engineering and the Department of Mechanical and Materials Engineering, The experimental procedures involving human subjects described herein were approved by the University's Research Ethics Board","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.10810472,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":96},"biblio":{"volume":"2016","issue":null,"first_page":"6489","last_page":"6492"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10868","display_name":"Soft Robotics and Applications","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10868","display_name":"Soft Robotics and Applications","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10338","display_name":"Advanced Sensor and Energy Harvesting Materials","score":0.9896000027656555,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10916","display_name":"Surgical Simulation and Training","score":0.9890999794006348,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/palpation","display_name":"Palpation","score":0.8635754585266113},{"id":"https://openalex.org/keywords/tactile-sensor","display_name":"Tactile sensor","score":0.7122945189476013},{"id":"https://openalex.org/keywords/capacitive-sensing","display_name":"Capacitive sensing","score":0.6697321534156799},{"id":"https://openalex.org/keywords/piezoresistive-effect","display_name":"Piezoresistive effect","score":0.601088285446167},{"id":"https://openalex.org/keywords/surgical-instrument","display_name":"Surgical instrument","score":0.5988914966583252},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.5223425626754761},{"id":"https://openalex.org/keywords/invasive-surgery","display_name":"Invasive surgery","score":0.4947928786277771},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.48206645250320435},{"id":"https://openalex.org/keywords/robot-end-effector","display_name":"Robot end effector","score":0.4471226930618286},{"id":"https://openalex.org/keywords/3d-printed","display_name":"3d printed","score":0.43670204281806946},{"id":"https://openalex.org/keywords/computer-vision","display_name":"Computer vision","score":0.369205117225647},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.3622779846191406},{"id":"https://openalex.org/keywords/computer-hardware","display_name":"Computer hardware","score":0.35277336835861206},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.2499641478061676},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.22657331824302673},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.22599995136260986},{"id":"https://openalex.org/keywords/surgery","display_name":"Surgery","score":0.2175397276878357},{"id":"https://openalex.org/keywords/robot","display_name":"Robot","score":0.15967652201652527}],"concepts":[{"id":"https://openalex.org/C2781167935","wikidata":"https://www.wikidata.org/wiki/Q795090","display_name":"Palpation","level":2,"score":0.8635754585266113},{"id":"https://openalex.org/C46722567","wikidata":"https://www.wikidata.org/wiki/Q7674139","display_name":"Tactile sensor","level":3,"score":0.7122945189476013},{"id":"https://openalex.org/C206755178","wikidata":"https://www.wikidata.org/wiki/Q1131271","display_name":"Capacitive sensing","level":2,"score":0.6697321534156799},{"id":"https://openalex.org/C198490522","wikidata":"https://www.wikidata.org/wiki/Q1932915","display_name":"Piezoresistive effect","level":2,"score":0.601088285446167},{"id":"https://openalex.org/C2778181360","wikidata":"https://www.wikidata.org/wiki/Q1074814","display_name":"Surgical instrument","level":2,"score":0.5988914966583252},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.5223425626754761},{"id":"https://openalex.org/C3019477240","wikidata":"https://www.wikidata.org/wiki/Q1755504","display_name":"Invasive surgery","level":2,"score":0.4947928786277771},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.48206645250320435},{"id":"https://openalex.org/C8652668","wikidata":"https://www.wikidata.org/wiki/Q1340324","display_name":"Robot end effector","level":3,"score":0.4471226930618286},{"id":"https://openalex.org/C3019308078","wikidata":"https://www.wikidata.org/wiki/Q229367","display_name":"3d printed","level":2,"score":0.43670204281806946},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.369205117225647},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.3622779846191406},{"id":"https://openalex.org/C9390403","wikidata":"https://www.wikidata.org/wiki/Q3966","display_name":"Computer hardware","level":1,"score":0.35277336835861206},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.2499641478061676},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.22657331824302673},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.22599995136260986},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.2175397276878357},{"id":"https://openalex.org/C90509273","wikidata":"https://www.wikidata.org/wiki/Q11012","display_name":"Robot","level":2,"score":0.15967652201652527},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D005246","descriptor_name":"Feedback","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D005246","descriptor_name":"Feedback","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D005246","descriptor_name":"Feedback","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D009369","descriptor_name":"Neoplasms","qualifier_ui":"Q000601","qualifier_name":"surgery","is_major_topic":false},{"descriptor_ui":"D009369","descriptor_name":"Neoplasms","qualifier_ui":"Q000601","qualifier_name":"surgery","is_major_topic":false},{"descriptor_ui":"D009369","descriptor_name":"Neoplasms","qualifier_ui":"Q000601","qualifier_name":"surgery","is_major_topic":false},{"descriptor_ui":"D010173","descriptor_name":"Palpation","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D010173","descriptor_name":"Palpation","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D010173","descriptor_name":"Palpation","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D013242","descriptor_name":"Sterilization","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013242","descriptor_name":"Sterilization","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013242","descriptor_name":"Sterilization","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014110","descriptor_name":"Touch","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014110","descriptor_name":"Touch","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014110","descriptor_name":"Touch","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019060","descriptor_name":"Minimally Invasive Surgical Procedures","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D019060","descriptor_name":"Minimally Invasive Surgical Procedures","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D019060","descriptor_name":"Minimally Invasive Surgical Procedures","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D059015","descriptor_name":"Wireless Technology","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D059015","descriptor_name":"Wireless Technology","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D059015","descriptor_name":"Wireless Technology","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false}],"locations_count":3,"locations":[{"id":"doi:10.1109/embc.2016.7592215","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2016.7592215","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},{"id":"pmid:28269733","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/28269733","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null},{"id":"pmh:oai:ir.lib.uwo.ca:mechanicalpub-1044","is_oa":false,"landing_page_url":"https://ir.lib.uwo.ca/mechanicalpub/42","pdf_url":null,"source":{"id":"https://openalex.org/S4306400648","display_name":"Scholarship@Western (Western University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I125749732","host_organization_name":"Western University","host_organization_lineage":["https://openalex.org/I125749732"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Mechanical and Materials Engineering Publications","raw_type":"conference"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Good health and well-being","id":"https://metadata.un.org/sdg/3","score":0.5400000214576721}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":15,"referenced_works":["https://openalex.org/W152135277","https://openalex.org/W1557783360","https://openalex.org/W1988125844","https://openalex.org/W1993693493","https://openalex.org/W2019690914","https://openalex.org/W2065548528","https://openalex.org/W2075635750","https://openalex.org/W2077544344","https://openalex.org/W2082983068","https://openalex.org/W2118215144","https://openalex.org/W2145632883","https://openalex.org/W2160672537","https://openalex.org/W2314604476","https://openalex.org/W6606209205","https://openalex.org/W6667172267"],"related_works":["https://openalex.org/W2769603963","https://openalex.org/W2159073493","https://openalex.org/W2746515375","https://openalex.org/W1038315188","https://openalex.org/W2080352772","https://openalex.org/W2532284183","https://openalex.org/W2605829637","https://openalex.org/W3108136916","https://openalex.org/W1644188304","https://openalex.org/W2047441444"],"abstract_inverted_index":{"Minimally":[0],"invasive":[1,30],"surgery":[2,31],"prevents":[3],"surgeons":[4],"from":[5],"manually":[6],"palpating":[7],"organs":[8],"to":[9,19,40,83,104,121,123,150,181,184],"locate":[10],"subsurface":[11],"tumors":[12,190],"and":[13,62,86,154,165],"other":[14],"structures.":[15],"One":[16],"solution":[17],"is":[18,24,179],"use":[20,91,173],"ultrasound;":[21],"however,":[22,47],"it":[23],"not":[25],"always":[26],"reliable.":[27],"Various":[28],"minimally":[29],"instruments":[32],"that":[33,75,117,143],"provide":[34,84],"tactile":[35,81,85,96,160],"feedback":[36],"have":[37,50,169],"been":[38,170],"proposed":[39],"augment":[41],"ultrasound":[42],"sensing":[43,164,167],"for":[44,172],"tumor":[45],"localization;":[46],"current":[48],"designs":[49],"limitations":[51],"such":[52],"as":[53],"cumbersome":[54],"wiring,":[55],"difficulty":[56],"in":[57,100,113,127,139,197],"manipulation,":[58],"lack":[59],"of":[60,92,131,134,147,158,194],"sterilizability":[61],"high":[63],"cost.":[64],"This":[65],"paper":[66],"presents":[67],"a":[68,77,93,110,128,140,192],"novel,":[69],"autoclavable,":[70],"wireless,":[71],"hand-held":[72],"palpation":[73,125],"instrument":[74,108,149,178],"uses":[76],"custom,":[78],"low-cost,":[79],"disposable":[80,95],"sensor":[82,97,101,120],"kinesthetic":[87],"force":[88],"feedback.":[89],"The":[90,107,177],"replaceable,":[94],"avoids":[98],"deterioration":[99],"performance":[102],"due":[103],"repeated":[105],"autoclaving.":[106],"features":[109],"passive":[111],"joint":[112],"the":[114,119,124,135,145,148,159],"end":[115],"effector":[116],"allows":[118,144],"self-align":[122],"surface":[126],"wide":[129],"range":[130],"orientations.":[132],"All":[133],"electronics":[136],"are":[137],"packaged":[138],"removable":[141],"module":[142],"rest":[146],"be":[151,182],"easily":[152],"cleaned":[153],"autoclaved.":[155],"Two":[156],"versions":[157],"sensor,":[161],"using":[162],"piezoresistive":[163],"capacitive":[166],"respectively,":[168],"designed":[171],"with":[174],"this":[175],"instrument.":[176],"shown":[180],"able":[183],"detect":[185],"6":[186],"mm":[187,196],"diameter":[188],"spherical":[189],"at":[191],"depth":[193],"9-10":[195],"ex":[198],"vivo":[199],"tissue":[200],"samples.":[201]},"counts_by_year":[{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
