{"id":"https://openalex.org/W2536035138","doi":"https://doi.org/10.1109/embc.2016.7591806","title":"An inductive narrow-pulse RFID telemetry system for gastric slow waves monitoring","display_name":"An inductive narrow-pulse RFID telemetry system for gastric slow waves monitoring","publication_year":2016,"publication_date":"2016-08-01","ids":{"openalex":"https://openalex.org/W2536035138","doi":"https://doi.org/10.1109/embc.2016.7591806","mag":"2536035138","pmid":"https://pubmed.ncbi.nlm.nih.gov/28269349"},"language":"en","primary_location":{"id":"doi:10.1109/embc.2016.7591806","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2016.7591806","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5041487518","display_name":"Amir Javan-Khoskholgh","orcid":null},"institutions":[{"id":"https://openalex.org/I4210104314","display_name":"New York Institute of Technology","ror":"https://ror.org/01bghzb51","country_code":"US","type":"education","lineage":["https://openalex.org/I4210104314"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Amir Javan-Khoskholgh","raw_affiliation_strings":["Integrated Medical Systems(IMS) Laboratory, New York Institute of Technology, Old Westbury, NY, USA"],"affiliations":[{"raw_affiliation_string":"Integrated Medical Systems(IMS) Laboratory, New York Institute of Technology, Old Westbury, NY, USA","institution_ids":["https://openalex.org/I4210104314"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5077530090","display_name":"Zaid Abukhalaf","orcid":null},"institutions":[{"id":"https://openalex.org/I4210104314","display_name":"New York Institute of Technology","ror":"https://ror.org/01bghzb51","country_code":"US","type":"education","lineage":["https://openalex.org/I4210104314"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Zaid Abukhalaf","raw_affiliation_strings":["Integrated Medical Systems(IMS) Laboratory, New York Institute of Technology, Old Westbury, NY, USA"],"affiliations":[{"raw_affiliation_string":"Integrated Medical Systems(IMS) Laboratory, New York Institute of Technology, Old Westbury, NY, USA","institution_ids":["https://openalex.org/I4210104314"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5110607310","display_name":"Li Ji","orcid":"https://orcid.org/0000-0001-7500-0660"},"institutions":[{"id":"https://openalex.org/I4210104314","display_name":"New York Institute of Technology","ror":"https://ror.org/01bghzb51","country_code":"US","type":"education","lineage":["https://openalex.org/I4210104314"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ji Li","raw_affiliation_strings":["Integrated Medical Systems(IMS) Laboratory, New York Institute of Technology, Old Westbury, NY, USA"],"affiliations":[{"raw_affiliation_string":"Integrated Medical Systems(IMS) Laboratory, New York Institute of Technology, Old Westbury, NY, USA","institution_ids":["https://openalex.org/I4210104314"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5070530684","display_name":"Larry S. Miller","orcid":"https://orcid.org/0000-0002-0148-2297"},"institutions":[{"id":"https://openalex.org/I2800560132","display_name":"Long Island Jewish Medical Center","ror":"https://ror.org/00c8v4891","country_code":"US","type":"healthcare","lineage":["https://openalex.org/I1302444339","https://openalex.org/I2800560132"]},{"id":"https://openalex.org/I1302444339","display_name":"Northwell Health","ror":"https://ror.org/02bxt4m23","country_code":"US","type":"funder","lineage":["https://openalex.org/I1302444339"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Larry S. Miller","raw_affiliation_strings":["Northwell Health System, Long Island Jewish Medical Center 270-05 76th Ave., New Hyde Park, NY, USA"],"affiliations":[{"raw_affiliation_string":"Northwell Health System, Long Island Jewish Medical Center 270-05 76th Ave., New Hyde Park, NY, USA","institution_ids":["https://openalex.org/I2800560132","https://openalex.org/I1302444339"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5056897984","display_name":"Mehdi Kiani","orcid":"https://orcid.org/0000-0001-9310-8093"},"institutions":[{"id":"https://openalex.org/I130769515","display_name":"Pennsylvania State University","ror":"https://ror.org/04p491231","country_code":"US","type":"education","lineage":["https://openalex.org/I130769515"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Mehdi Kiani","raw_affiliation_strings":["Electrical Engineering Department, Pennsylvania State University, PA, USA"],"affiliations":[{"raw_affiliation_string":"Electrical Engineering Department, Pennsylvania State University, PA, USA","institution_ids":["https://openalex.org/I130769515"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5060930366","display_name":"Aydin Farajidavar","orcid":"https://orcid.org/0000-0002-2073-0073"},"institutions":[{"id":"https://openalex.org/I4210104314","display_name":"New York Institute of Technology","ror":"https://ror.org/01bghzb51","country_code":"US","type":"education","lineage":["https://openalex.org/I4210104314"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Aydin Farajidavar","raw_affiliation_strings":["New York Institute of Technology, Old Westbury, NY, US"],"affiliations":[{"raw_affiliation_string":"New York Institute of Technology, Old Westbury, NY, US","institution_ids":["https://openalex.org/I4210104314"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":["https://openalex.org/A5041487518"],"corresponding_institution_ids":["https://openalex.org/I4210104314"],"apc_list":null,"apc_paid":null,"fwci":0.5513,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.71607824,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":"2016","issue":null,"first_page":"4820","last_page":"4823"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11249","display_name":"Wireless Power Transfer Systems","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11249","display_name":"Wireless Power Transfer Systems","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10663","display_name":"Advanced Battery Technologies Research","score":0.9879999756813049,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11932","display_name":"Wireless Body Area Networks","score":0.9878000020980835,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/telemetry","display_name":"Telemetry","score":0.7102908492088318},{"id":"https://openalex.org/keywords/microcontroller","display_name":"Microcontroller","score":0.6522632241249084},{"id":"https://openalex.org/keywords/transceiver","display_name":"Transceiver","score":0.6085449457168579},{"id":"https://openalex.org/keywords/computer-hardware","display_name":"Computer hardware","score":0.60566645860672},{"id":"https://openalex.org/keywords/data-transmission","display_name":"Data transmission","score":0.5914047956466675},{"id":"https://openalex.org/keywords/telecommunications-link","display_name":"Telecommunications link","score":0.5514073967933655},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5370435118675232},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.4754352569580078},{"id":"https://openalex.org/keywords/amplitude-shift-keying","display_name":"Amplitude-shift keying","score":0.44630947709083557},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.4413623809814453},{"id":"https://openalex.org/keywords/duty-cycle","display_name":"Duty cycle","score":0.44015270471572876},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.394431471824646},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.3883785605430603},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.3689144253730774},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.34829697012901306},{"id":"https://openalex.org/keywords/bit-error-rate","display_name":"Bit error rate","score":0.30197298526763916},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.28345298767089844},{"id":"https://openalex.org/keywords/phase-shift-keying","display_name":"Phase-shift keying","score":0.23895856738090515},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.18872329592704773},{"id":"https://openalex.org/keywords/channel","display_name":"Channel (broadcasting)","score":0.15093061327934265}],"concepts":[{"id":"https://openalex.org/C183121708","wikidata":"https://www.wikidata.org/wiki/Q209867","display_name":"Telemetry","level":2,"score":0.7102908492088318},{"id":"https://openalex.org/C173018170","wikidata":"https://www.wikidata.org/wiki/Q165678","display_name":"Microcontroller","level":2,"score":0.6522632241249084},{"id":"https://openalex.org/C7720470","wikidata":"https://www.wikidata.org/wiki/Q954187","display_name":"Transceiver","level":3,"score":0.6085449457168579},{"id":"https://openalex.org/C9390403","wikidata":"https://www.wikidata.org/wiki/Q3966","display_name":"Computer hardware","level":1,"score":0.60566645860672},{"id":"https://openalex.org/C557945733","wikidata":"https://www.wikidata.org/wiki/Q389772","display_name":"Data transmission","level":2,"score":0.5914047956466675},{"id":"https://openalex.org/C138660444","wikidata":"https://www.wikidata.org/wiki/Q5607897","display_name":"Telecommunications link","level":2,"score":0.5514073967933655},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5370435118675232},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.4754352569580078},{"id":"https://openalex.org/C2777973058","wikidata":"https://www.wikidata.org/wiki/Q477284","display_name":"Amplitude-shift keying","level":5,"score":0.44630947709083557},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.4413623809814453},{"id":"https://openalex.org/C199822604","wikidata":"https://www.wikidata.org/wiki/Q557120","display_name":"Duty cycle","level":3,"score":0.44015270471572876},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.394431471824646},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3883785605430603},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.3689144253730774},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.34829697012901306},{"id":"https://openalex.org/C56296756","wikidata":"https://www.wikidata.org/wiki/Q840922","display_name":"Bit error rate","level":3,"score":0.30197298526763916},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.28345298767089844},{"id":"https://openalex.org/C186378180","wikidata":"https://www.wikidata.org/wiki/Q4874866","display_name":"Phase-shift keying","level":4,"score":0.23895856738090515},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.18872329592704773},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.15093061327934265},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.0}],"mesh":[{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004068","descriptor_name":"Digestive System Physiological Phenomena","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004068","descriptor_name":"Digestive System Physiological Phenomena","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004068","descriptor_name":"Digestive System Physiological Phenomena","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D012984","descriptor_name":"Software","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012984","descriptor_name":"Software","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012984","descriptor_name":"Software","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013270","descriptor_name":"Stomach","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D013270","descriptor_name":"Stomach","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D013270","descriptor_name":"Stomach","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D013686","descriptor_name":"Telemetry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D013686","descriptor_name":"Telemetry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D013686","descriptor_name":"Telemetry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D013686","descriptor_name":"Telemetry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D013686","descriptor_name":"Telemetry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D013686","descriptor_name":"Telemetry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D019736","descriptor_name":"Prostheses and Implants","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019736","descriptor_name":"Prostheses and Implants","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019736","descriptor_name":"Prostheses and Implants","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D057233","descriptor_name":"Radio Frequency Identification Device","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D057233","descriptor_name":"Radio Frequency Identification Device","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D057233","descriptor_name":"Radio Frequency Identification Device","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D059015","descriptor_name":"Wireless Technology","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D059015","descriptor_name":"Wireless Technology","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D059015","descriptor_name":"Wireless Technology","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/embc.2016.7591806","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2016.7591806","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},{"id":"pmid:28269349","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/28269349","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W643058322","https://openalex.org/W1965442232","https://openalex.org/W1975844672","https://openalex.org/W2052919971","https://openalex.org/W2070564499","https://openalex.org/W2074468958","https://openalex.org/W2127342360","https://openalex.org/W2161585794","https://openalex.org/W2169061942","https://openalex.org/W2294399778","https://openalex.org/W6684990875"],"related_works":["https://openalex.org/W2070863773","https://openalex.org/W4212896802","https://openalex.org/W2056771637","https://openalex.org/W4386075467","https://openalex.org/W1996677803","https://openalex.org/W4285011734","https://openalex.org/W1989853354","https://openalex.org/W2044671868","https://openalex.org/W2159128229","https://openalex.org/W2049638496"],"abstract_inverted_index":{"We":[0],"present":[1],"a":[2,15,29,34,48,71,153,156,213],"passive":[3],"data":[4,63,81,100,107,142,183,192,202],"telemetry":[5,64],"system":[6,19,65],"for":[7,160],"real-time":[8,161],"monitoring":[9],"of":[10,14,22,167],"gastric":[11],"electrical":[12],"activity":[13],"living":[16],"subject.":[17],"The":[18,104,165],"is":[20,45,88,124],"composed":[21],"three":[23],"subsystems:":[24],"an":[25,114,136],"implantable":[26],"unit":[27,31,36],"(IU),":[28],"wearable":[30],"(WU),":[32],"and":[33,43,61,97,106,163,179,197,206],"stationary":[35],"(SU).":[37],"Data":[38],"communication":[39,82],"between":[40,199],"the":[41,67,119,127,130,140,144,149,168,171,191,200,204,209],"IU":[42,120,205],"WU":[44,128,145],"based":[46],"on":[47,170],"radio-frequency":[49],"identification":[50],"(RFID)":[51],"link":[52],"operating":[53],"at":[54,118,143],"13.56":[55],"MHz.":[56],"Since":[57],"wireless":[58,93],"power":[59,95],"transmission":[60,96,184],"reverse":[62],"share":[66],"same":[68],"inductive":[69,131],"interface,":[70],"load":[72],"shift":[73],"keying":[74],"(LSK)-based":[75],"differential":[76],"pulse":[77],"position":[78],"(DPP)":[79],"coding":[80],"with":[83,186],"only":[84],"6.25%":[85],"duty":[86],"cycle":[87],"developed":[89],"to":[90,126,148,152],"guarantee":[91],"consistent":[92],"downlink":[94],"uplink":[98],"high":[99],"transfer":[101],"rate,":[102],"simultaneously.":[103],"clock":[105],"are":[108,146],"encoded":[109],"into":[110],"one":[111],"signal":[112,123],"by":[113,135,203,208,212],"MSP430":[115],"microcontroller":[116],"(MCU)":[117],"side.":[121],"This":[122],"sent":[125],"through":[129],"link,":[132],"where":[133],"decoded":[134],"MSP432":[137],"MCU.":[138],"Finally,":[139],"retrieved":[141],"transmitted":[147,201],"SU":[150,210],"connected":[151],"PC":[154],"via":[155],"2.4":[157],"GHz":[158],"transceiver":[159],"display":[162],"analysis.":[164],"results":[166],"measurements":[169],"implemented":[172],"test":[173],"bench,":[174],"demonstrate":[175],"IU-WU":[176],"125":[177],"kb/s":[178],"WU-SU":[180],"2":[181],"Mb/s":[182],"rate":[185],"no":[187],"observed":[188],"mismatch,":[189],"while":[190],"stream":[193],"was":[194],"randomly":[195],"generated,":[196],"matching":[198],"received":[207],"verified":[211],"custom-made":[214],"automated":[215],"software.":[216]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":2},{"year":2018,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
