{"id":"https://openalex.org/W2296504842","doi":"https://doi.org/10.1109/embc.2015.7320048","title":"Biophone: Physiology monitoring from peripheral smartphone motions","display_name":"Biophone: Physiology monitoring from peripheral smartphone motions","publication_year":2015,"publication_date":"2015-08-01","ids":{"openalex":"https://openalex.org/W2296504842","doi":"https://doi.org/10.1109/embc.2015.7320048","mag":"2296504842","pmid":"https://pubmed.ncbi.nlm.nih.gov/26737948"},"language":"en","primary_location":{"id":"doi:10.1109/embc.2015.7320048","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2015.7320048","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"http://hdl.handle.net/1721.1/103784","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5022316351","display_name":"Javier Hernandez","orcid":"https://orcid.org/0000-0001-9504-5217"},"institutions":[{"id":"https://openalex.org/I63966007","display_name":"Massachusetts Institute of Technology","ror":"https://ror.org/042nb2s44","country_code":"US","type":"education","lineage":["https://openalex.org/I63966007"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Javier Hernandez","raw_affiliation_strings":["Media Lab, Massachusetts Institute of Technology, Cambridge, MA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Media Lab, Massachusetts Institute of Technology, Cambridge, MA, USA","institution_ids":["https://openalex.org/I63966007"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100681741","display_name":"Daniel McDuff","orcid":"https://orcid.org/0000-0001-7313-0082"},"institutions":[{"id":"https://openalex.org/I63966007","display_name":"Massachusetts Institute of Technology","ror":"https://ror.org/042nb2s44","country_code":"US","type":"education","lineage":["https://openalex.org/I63966007"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Daniel J. McDuff","raw_affiliation_strings":["Media Lab, Massachusetts Institute of Technology, Cambridge, MA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Media Lab, Massachusetts Institute of Technology, Cambridge, MA, USA","institution_ids":["https://openalex.org/I63966007"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5087366916","display_name":"Rosalind W. Picard","orcid":"https://orcid.org/0000-0002-5661-0022"},"institutions":[{"id":"https://openalex.org/I63966007","display_name":"Massachusetts Institute of Technology","ror":"https://ror.org/042nb2s44","country_code":"US","type":"education","lineage":["https://openalex.org/I63966007"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Rosalind W. Picard","raw_affiliation_strings":["Media Lab, Massachusetts Institute of Technology, Cambridge, MA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Media Lab, Massachusetts Institute of Technology, Cambridge, MA, USA","institution_ids":["https://openalex.org/I63966007"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I63966007"],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":55,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":"2015","issue":null,"first_page":"7180","last_page":"7183"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9957000017166138,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.9902999997138977,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/accelerometer","display_name":"Accelerometer","score":0.7860761880874634},{"id":"https://openalex.org/keywords/clearance","display_name":"Clearance","score":0.7120007276535034},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6261581182479858},{"id":"https://openalex.org/keywords/motion-sensors","display_name":"Motion sensors","score":0.4983692169189453},{"id":"https://openalex.org/keywords/phone","display_name":"Phone","score":0.4926000237464905},{"id":"https://openalex.org/keywords/breathing","display_name":"Breathing","score":0.4885135889053345},{"id":"https://openalex.org/keywords/respiratory-rate","display_name":"Respiratory rate","score":0.4337451159954071},{"id":"https://openalex.org/keywords/mobile-phone","display_name":"Mobile phone","score":0.41578859090805054},{"id":"https://openalex.org/keywords/heart-rate","display_name":"Heart rate","score":0.3914906978607178},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.35700273513793945},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.33924269676208496},{"id":"https://openalex.org/keywords/computer-vision","display_name":"Computer vision","score":0.2513207793235779},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.24395787715911865},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.11401090025901794}],"concepts":[{"id":"https://openalex.org/C89805583","wikidata":"https://www.wikidata.org/wiki/Q192940","display_name":"Accelerometer","level":2,"score":0.7860761880874634},{"id":"https://openalex.org/C138944611","wikidata":"https://www.wikidata.org/wiki/Q1163287","display_name":"Clearance","level":2,"score":0.7120007276535034},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6261581182479858},{"id":"https://openalex.org/C2986565385","wikidata":"https://www.wikidata.org/wiki/Q852453","display_name":"Motion sensors","level":2,"score":0.4983692169189453},{"id":"https://openalex.org/C2778707766","wikidata":"https://www.wikidata.org/wiki/Q202064","display_name":"Phone","level":2,"score":0.4926000237464905},{"id":"https://openalex.org/C39300077","wikidata":"https://www.wikidata.org/wiki/Q9530","display_name":"Breathing","level":2,"score":0.4885135889053345},{"id":"https://openalex.org/C8213797","wikidata":"https://www.wikidata.org/wiki/Q754250","display_name":"Respiratory rate","level":4,"score":0.4337451159954071},{"id":"https://openalex.org/C2777421447","wikidata":"https://www.wikidata.org/wiki/Q17517","display_name":"Mobile phone","level":2,"score":0.41578859090805054},{"id":"https://openalex.org/C2777953023","wikidata":"https://www.wikidata.org/wiki/Q1073121","display_name":"Heart rate","level":3,"score":0.3914906978607178},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.35700273513793945},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.33924269676208496},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.2513207793235779},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.24395787715911865},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.11401090025901794},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.0},{"id":"https://openalex.org/C41895202","wikidata":"https://www.wikidata.org/wiki/Q8162","display_name":"Linguistics","level":1,"score":0.0},{"id":"https://openalex.org/C138885662","wikidata":"https://www.wikidata.org/wiki/Q5891","display_name":"Philosophy","level":0,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C105702510","wikidata":"https://www.wikidata.org/wiki/Q514","display_name":"Anatomy","level":1,"score":0.0},{"id":"https://openalex.org/C126894567","wikidata":"https://www.wikidata.org/wiki/Q105650","display_name":"Urology","level":1,"score":0.0},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D000068997","descriptor_name":"Smartphone","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000068997","descriptor_name":"Smartphone","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000068997","descriptor_name":"Smartphone","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D005260","descriptor_name":"Female","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D005260","descriptor_name":"Female","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D005260","descriptor_name":"Female","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006339","descriptor_name":"Heart Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006339","descriptor_name":"Heart Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006339","descriptor_name":"Heart Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008297","descriptor_name":"Male","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008297","descriptor_name":"Male","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008297","descriptor_name":"Male","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D009038","descriptor_name":"Motion","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D009038","descriptor_name":"Motion","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D009038","descriptor_name":"Motion","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011187","descriptor_name":"Posture","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011187","descriptor_name":"Posture","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011187","descriptor_name":"Posture","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D056152","descriptor_name":"Respiratory Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D056152","descriptor_name":"Respiratory Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D056152","descriptor_name":"Respiratory Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false}],"locations_count":3,"locations":[{"id":"doi:10.1109/embc.2015.7320048","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2015.7320048","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},{"id":"pmid:26737948","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/26737948","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null},{"id":"pmh:oai:dspace.mit.edu:1721.1/103784","is_oa":true,"landing_page_url":"http://hdl.handle.net/1721.1/103784","pdf_url":null,"source":{"id":"https://openalex.org/S4306400425","display_name":"DSpace@MIT (Massachusetts Institute of Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I63966007","host_organization_name":"Massachusetts Institute of Technology","host_organization_lineage":["https://openalex.org/I63966007"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nc-sa","license_id":"https://openalex.org/licenses/cc-by-nc-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"MIT web domain","raw_type":"http://purl.org/eprint/type/ConferencePaper"}],"best_oa_location":{"id":"pmh:oai:dspace.mit.edu:1721.1/103784","is_oa":true,"landing_page_url":"http://hdl.handle.net/1721.1/103784","pdf_url":null,"source":{"id":"https://openalex.org/S4306400425","display_name":"DSpace@MIT (Massachusetts Institute of Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I63966007","host_organization_name":"Massachusetts Institute of Technology","host_organization_lineage":["https://openalex.org/I63966007"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nc-sa","license_id":"https://openalex.org/licenses/cc-by-nc-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"MIT web domain","raw_type":"http://purl.org/eprint/type/ConferencePaper"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","display_name":"Good health and well-being","score":0.4699999988079071}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":21,"referenced_works":["https://openalex.org/W1979316402","https://openalex.org/W1984554603","https://openalex.org/W1996112374","https://openalex.org/W2004720921","https://openalex.org/W2047261063","https://openalex.org/W2060642847","https://openalex.org/W2078126533","https://openalex.org/W2083872334","https://openalex.org/W2106971248","https://openalex.org/W2125057497","https://openalex.org/W2162273778","https://openalex.org/W2167217202","https://openalex.org/W2247908160","https://openalex.org/W2326035627","https://openalex.org/W2532881485","https://openalex.org/W2546006597","https://openalex.org/W2977783450","https://openalex.org/W3148244168","https://openalex.org/W4233421246","https://openalex.org/W6651359997","https://openalex.org/W6768745600"],"related_works":["https://openalex.org/W94007947","https://openalex.org/W2765080098","https://openalex.org/W2385749422","https://openalex.org/W1535945296","https://openalex.org/W4303613760","https://openalex.org/W2921132911","https://openalex.org/W2098383409","https://openalex.org/W2042041186","https://openalex.org/W2597358607","https://openalex.org/W3196195804"],"abstract_inverted_index":{"The":[0],"large-scale":[1],"adoption":[2],"of":[3,35,98],"smartphones":[4,30],"during":[5,38,122],"recent":[6],"years":[7],"has":[8],"created":[9],"many":[10],"opportunities":[11],"to":[12,56,93,134],"improve":[13],"health":[14],"monitoring":[15],"and":[16,59,65,87,90,105],"care":[17],"delivery.":[18],"In":[19,51],"this":[20],"work,":[21],"we":[22,53,117],"demonstrate":[23],"that":[24],"motion":[25],"sensors":[26],"available":[27],"in":[28,45],"off-the-shelf":[29],"can":[31],"capture":[32],"physiological":[33],"parameters":[34],"a":[36,46,49,130,135],"person":[37],"stationary":[39],"postures,":[40],"even":[41],"while":[42],"being":[43],"carried":[44],"bag":[47],"or":[48,132],"pocket.":[50],"particular,":[52],"develop":[54],"methods":[55,121],"extract":[57],"heart":[58],"breathing":[60],"rates":[61,143],"from":[62],"accelerometer":[63],"data":[64],"compare":[66],"them":[67],"with":[68,71],"measurements":[69],"obtained":[70],"FDA-cleared":[72],"sensors.":[73],"We":[74],"evaluated":[75,118],"their":[76],"accuracy":[77],"on":[78],"12":[79],"people":[80],"across":[81],"different":[82,114],"still":[83,140],"body":[84],"postures":[85],"(pre-":[86],"post-":[88],"exercise)":[89],"were":[91],"able":[92],"reach":[94],"mean":[95],"absolute":[96],"errors":[97],"1.16":[99],"beats":[100],"per":[101,108],"minute":[102,109],"(STD:":[103,110],"3)":[104],"0.26":[106],"breaths":[107],"0.5)":[111],"when":[112,128],"considering":[113],"conditions.":[115,146],"Furthermore,":[116],"the":[119],"same":[120],"regular":[123],"phone":[124],"activities,":[125],"such":[126],"as":[127],"watching":[129],"video":[131],"listening":[133],"conversation,":[136],"yielding":[137],"increased":[138],"but":[139],"comparable":[141],"error":[142],"for":[144],"some":[145]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":5},{"year":2020,"cited_by_count":6},{"year":2019,"cited_by_count":4},{"year":2018,"cited_by_count":13},{"year":2017,"cited_by_count":14},{"year":2016,"cited_by_count":4},{"year":2015,"cited_by_count":1}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
