{"id":"https://openalex.org/W2296764718","doi":"https://doi.org/10.1109/embc.2015.7319074","title":"A miniaturized electrolytic pump sensorized with a strain gauge based on thermoplastic nanocomposite for drug delivery systems","display_name":"A miniaturized electrolytic pump sensorized with a strain gauge based on thermoplastic nanocomposite for drug delivery systems","publication_year":2015,"publication_date":"2015-08-01","ids":{"openalex":"https://openalex.org/W2296764718","doi":"https://doi.org/10.1109/embc.2015.7319074","mag":"2296764718","pmid":"https://pubmed.ncbi.nlm.nih.gov/26736974"},"language":"en","primary_location":{"id":"doi:10.1109/embc.2015.7319074","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2015.7319074","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5000443278","display_name":"Rosa Goffredo","orcid":null},"institutions":[{"id":"https://openalex.org/I155125353","display_name":"Universit\u00e0 Campus Bio-Medico","ror":"https://ror.org/04gqx4x78","country_code":"IT","type":"education","lineage":["https://openalex.org/I155125353"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"R. Goffredo","raw_affiliation_strings":["Universita Campus Bio-Medico di Roma, Roma, Lazio, IT"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universita Campus Bio-Medico di Roma, Roma, Lazio, IT","institution_ids":["https://openalex.org/I155125353"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5000064754","display_name":"Andrea Ferrone","orcid":null},"institutions":[{"id":"https://openalex.org/I119003972","display_name":"Roma Tre University","ror":"https://ror.org/05vf0dg29","country_code":"IT","type":"education","lineage":["https://openalex.org/I119003972"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"A. Ferrone","raw_affiliation_strings":["Universita degli Studi Roma Tre, Roma, Lazio, IT"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universita degli Studi Roma Tre, Roma, Lazio, IT","institution_ids":["https://openalex.org/I119003972"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5063590667","display_name":"Luca Maiolo","orcid":"https://orcid.org/0000-0003-3220-5353"},"institutions":[{"id":"https://openalex.org/I4210165120","display_name":"Institute for Microelectronics and Microsystems","ror":"https://ror.org/05vk2g845","country_code":"IT","type":"facility","lineage":["https://openalex.org/I4210155236","https://openalex.org/I4210165120"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"L. Maiolo","raw_affiliation_strings":["Consiglio Nazionale delle Ricerche Via del, IMM-Istituto per la Microelettronica e Microsistemi CNR, Roma, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Consiglio Nazionale delle Ricerche Via del, IMM-Istituto per la Microelettronica e Microsistemi CNR, Roma, Italy","institution_ids":["https://openalex.org/I4210165120"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5021002400","display_name":"A. Pecora","orcid":"https://orcid.org/0000-0001-6186-3684"},"institutions":[{"id":"https://openalex.org/I4210165120","display_name":"Institute for Microelectronics and Microsystems","ror":"https://ror.org/05vk2g845","country_code":"IT","type":"facility","lineage":["https://openalex.org/I4210155236","https://openalex.org/I4210165120"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"A. Pecora","raw_affiliation_strings":["Consiglio Nazionale delle Ricerche Via del, IMM-Istituto per la Microelettronica e Microsistemi CNR, Roma, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Consiglio Nazionale delle Ricerche Via del, IMM-Istituto per la Microelettronica e Microsistemi CNR, Roma, Italy","institution_ids":["https://openalex.org/I4210165120"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5018019710","display_name":"Dino Accoto","orcid":"https://orcid.org/0000-0001-9039-5488"},"institutions":[{"id":"https://openalex.org/I155125353","display_name":"Universit\u00e0 Campus Bio-Medico","ror":"https://ror.org/04gqx4x78","country_code":"IT","type":"education","lineage":["https://openalex.org/I155125353"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"D. Accoto","raw_affiliation_strings":["Universita Campus Bio-Medico di Roma, Roma, Lazio, IT"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universita Campus Bio-Medico di Roma, Roma, Lazio, IT","institution_ids":["https://openalex.org/I155125353"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.5457,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.69336481,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":"9","issue":null,"first_page":"3205","last_page":"3208"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10338","display_name":"Advanced Sensor and Energy Harvesting Materials","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10338","display_name":"Advanced Sensor and Energy Harvesting Materials","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11472","display_name":"Analytical Chemistry and Sensors","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/1502","display_name":"Bioengineering"},"field":{"id":"https://openalex.org/fields/15","display_name":"Chemical Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11608","display_name":"Dielectric materials and actuators","score":0.9987000226974487,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.7756232023239136},{"id":"https://openalex.org/keywords/electrolyte","display_name":"Electrolyte","score":0.681182324886322},{"id":"https://openalex.org/keywords/electrode","display_name":"Electrode","score":0.6043241024017334},{"id":"https://openalex.org/keywords/nanocomposite","display_name":"Nanocomposite","score":0.5848591923713684},{"id":"https://openalex.org/keywords/elastomer","display_name":"Elastomer","score":0.575503408908844},{"id":"https://openalex.org/keywords/strain-gauge","display_name":"Strain gauge","score":0.565392017364502},{"id":"https://openalex.org/keywords/thermoplastic-elastomer","display_name":"Thermoplastic elastomer","score":0.5562489032745361},{"id":"https://openalex.org/keywords/electrical-conductor","display_name":"Electrical conductor","score":0.54848313331604},{"id":"https://openalex.org/keywords/composite-material","display_name":"Composite material","score":0.5270431637763977},{"id":"https://openalex.org/keywords/membrane","display_name":"Membrane","score":0.4610994756221771},{"id":"https://openalex.org/keywords/nanotechnology","display_name":"Nanotechnology","score":0.3511652648448944},{"id":"https://openalex.org/keywords/polymer","display_name":"Polymer","score":0.3149099349975586},{"id":"https://openalex.org/keywords/chemistry","display_name":"Chemistry","score":0.10782691836357117}],"concepts":[{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.7756232023239136},{"id":"https://openalex.org/C68801617","wikidata":"https://www.wikidata.org/wiki/Q162908","display_name":"Electrolyte","level":3,"score":0.681182324886322},{"id":"https://openalex.org/C17525397","wikidata":"https://www.wikidata.org/wiki/Q176140","display_name":"Electrode","level":2,"score":0.6043241024017334},{"id":"https://openalex.org/C92880739","wikidata":"https://www.wikidata.org/wiki/Q2639556","display_name":"Nanocomposite","level":2,"score":0.5848591923713684},{"id":"https://openalex.org/C38052585","wikidata":"https://www.wikidata.org/wiki/Q252266","display_name":"Elastomer","level":2,"score":0.575503408908844},{"id":"https://openalex.org/C60584519","wikidata":"https://www.wikidata.org/wiki/Q610723","display_name":"Strain gauge","level":2,"score":0.565392017364502},{"id":"https://openalex.org/C92328351","wikidata":"https://www.wikidata.org/wiki/Q146527","display_name":"Thermoplastic elastomer","level":4,"score":0.5562489032745361},{"id":"https://openalex.org/C202374169","wikidata":"https://www.wikidata.org/wiki/Q124291","display_name":"Electrical conductor","level":2,"score":0.54848313331604},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.5270431637763977},{"id":"https://openalex.org/C41625074","wikidata":"https://www.wikidata.org/wiki/Q176088","display_name":"Membrane","level":2,"score":0.4610994756221771},{"id":"https://openalex.org/C171250308","wikidata":"https://www.wikidata.org/wiki/Q11468","display_name":"Nanotechnology","level":1,"score":0.3511652648448944},{"id":"https://openalex.org/C521977710","wikidata":"https://www.wikidata.org/wiki/Q81163","display_name":"Polymer","level":2,"score":0.3149099349975586},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.10782691836357117},{"id":"https://openalex.org/C15920480","wikidata":"https://www.wikidata.org/wiki/Q421281","display_name":"Copolymer","level":3,"score":0.0},{"id":"https://openalex.org/C147789679","wikidata":"https://www.wikidata.org/wiki/Q11372","display_name":"Physical chemistry","level":1,"score":0.0},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D004566","descriptor_name":"Electrodes","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004566","descriptor_name":"Electrodes","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004566","descriptor_name":"Electrodes","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004572","descriptor_name":"Electrolysis","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D004572","descriptor_name":"Electrolysis","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D004572","descriptor_name":"Electrolysis","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D016503","descriptor_name":"Drug Delivery Systems","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D016503","descriptor_name":"Drug Delivery Systems","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D016503","descriptor_name":"Drug Delivery Systems","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D020724","descriptor_name":"Elastomers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D020724","descriptor_name":"Elastomers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D020724","descriptor_name":"Elastomers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D053761","descriptor_name":"Nanocomposites","qualifier_ui":"Q000737","qualifier_name":"chemistry","is_major_topic":false},{"descriptor_ui":"D053761","descriptor_name":"Nanocomposites","qualifier_ui":"Q000737","qualifier_name":"chemistry","is_major_topic":false},{"descriptor_ui":"D053761","descriptor_name":"Nanocomposites","qualifier_ui":"Q000737","qualifier_name":"chemistry","is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/embc.2015.7319074","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2015.7319074","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},{"id":"pmid:26736974","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/26736974","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.7099999785423279,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W1966181935","https://openalex.org/W1999959880","https://openalex.org/W2043394999","https://openalex.org/W2051230121","https://openalex.org/W2078835847","https://openalex.org/W2115628119","https://openalex.org/W2120543134","https://openalex.org/W2132738068","https://openalex.org/W2137717889","https://openalex.org/W2161559245"],"related_works":["https://openalex.org/W1483110363","https://openalex.org/W3144433931","https://openalex.org/W2290118421","https://openalex.org/W2252397596","https://openalex.org/W3081417525","https://openalex.org/W2476909180","https://openalex.org/W278562664","https://openalex.org/W3183621543","https://openalex.org/W3196488182","https://openalex.org/W4307417638"],"abstract_inverted_index":{"In":[0,64],"this":[1,112],"paper":[2],"we":[3],"present":[4],"a":[5,11,22,80,88,108],"miniature":[6],"electrolytic":[7,30,43,61],"pump":[8],"sensorized":[9],"with":[10],"novel":[12],"strain":[13,81],"sensor":[14,83,95],"to":[15,66,123,132],"be":[16],"used":[17],"as":[18],"active":[19],"component":[20],"of":[21,28,77,115,127],"drug":[23,78],"delivery":[24],"system.":[25],"It":[26],"consists":[27],"an":[29,56],"solution":[31,62],"reservoir":[32],"where":[33],"inert":[34],"electrodes":[35],"are":[36],"immersed.":[37],"By":[38],"polarizing":[39],"the":[40,42,48,60,70,75,100,120,125,128],"electrodes,":[41],"reaction":[44],"is":[45,107],"activated":[46],"and":[47,53,68,73],"produced":[49],"gases":[50],"(i.e.":[51],"oxygen":[52],"hydrogen)":[54],"displace":[55],"elastic":[57],"membrane":[58,71],"delimiting":[59],"reservoir.":[63],"order":[65,131],"measure":[67],"monitor":[69],"displacement,":[72],"therefore":[74],"volume":[76],"ejected,":[79],"gauge":[82],"has":[84,96],"been":[85,97],"prepared":[86],"using":[87],"conductive":[89,104],"thermoplastic":[90,105],"nanocomposite":[91],"elastomer":[92,106],"(CTPE).":[93],"The":[94,103],"fixed":[98],"on":[99],"deformable":[101],"membrane.":[102],"good":[109],"candidate":[110],"for":[111],"application":[113],"because":[114],"its":[116],"high":[117],"sensitivity.":[118],"Furthermore,":[119],"CTPE":[121],"allows":[122],"customize":[124],"resistance":[126],"device":[129],"in":[130],"obtain":[133],"low":[134],"power":[135],"consumption.":[136]},"counts_by_year":[{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
