{"id":"https://openalex.org/W2293741087","doi":"https://doi.org/10.1109/embc.2015.7318706","title":"Wearable lung-health monitoring system with electrical impedance tomography","display_name":"Wearable lung-health monitoring system with electrical impedance tomography","publication_year":2015,"publication_date":"2015-08-01","ids":{"openalex":"https://openalex.org/W2293741087","doi":"https://doi.org/10.1109/embc.2015.7318706","mag":"2293741087","pmid":"https://pubmed.ncbi.nlm.nih.gov/26736606"},"language":"en","primary_location":{"id":"doi:10.1109/embc.2015.7318706","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2015.7318706","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5033788275","display_name":"Sunjoo Hong","orcid":null},"institutions":[{"id":"https://openalex.org/I157485424","display_name":"Korea Advanced Institute of Science and Technology","ror":"https://ror.org/05apxxy63","country_code":"KR","type":"education","lineage":["https://openalex.org/I157485424"]}],"countries":["KR"],"is_corresponding":true,"raw_author_name":"Sunjoo Hong","raw_affiliation_strings":["Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 305-701, Republic of Korea","Korea Advanced Institute of Science and Technology (KAIST), Yuseong-gu, Daejeon, Republic of Korea"],"affiliations":[{"raw_affiliation_string":"Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 305-701, Republic of Korea","institution_ids":["https://openalex.org/I157485424"]},{"raw_affiliation_string":"Korea Advanced Institute of Science and Technology (KAIST), Yuseong-gu, Daejeon, Republic of Korea","institution_ids":["https://openalex.org/I157485424"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5011205347","display_name":"Jaehyuk Lee","orcid":"https://orcid.org/0000-0001-7113-1161"},"institutions":[{"id":"https://openalex.org/I157485424","display_name":"Korea Advanced Institute of Science and Technology","ror":"https://ror.org/05apxxy63","country_code":"KR","type":"education","lineage":["https://openalex.org/I157485424"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Jaehyuk Lee","raw_affiliation_strings":["Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 305-701, Republic of Korea","Korea Advanced Institute of Science and Technology (KAIST), Yuseong-gu, Daejeon, Republic of Korea"],"affiliations":[{"raw_affiliation_string":"Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 305-701, Republic of Korea","institution_ids":["https://openalex.org/I157485424"]},{"raw_affiliation_string":"Korea Advanced Institute of Science and Technology (KAIST), Yuseong-gu, Daejeon, Republic of Korea","institution_ids":["https://openalex.org/I157485424"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5077896259","display_name":"Hoi\u2010Jun Yoo","orcid":"https://orcid.org/0000-0002-6661-4879"},"institutions":[{"id":"https://openalex.org/I157485424","display_name":"Korea Advanced Institute of Science and Technology","ror":"https://ror.org/05apxxy63","country_code":"KR","type":"education","lineage":["https://openalex.org/I157485424"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Hoi-Jun Yoo","raw_affiliation_strings":["Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 305-701, Republic of Korea","Korea Advanced Institute of Science and Technology (KAIST), Yuseong-gu, Daejeon, Republic of Korea"],"affiliations":[{"raw_affiliation_string":"Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 305-701, Republic of Korea","institution_ids":["https://openalex.org/I157485424"]},{"raw_affiliation_string":"Korea Advanced Institute of Science and Technology (KAIST), Yuseong-gu, Daejeon, Republic of Korea","institution_ids":["https://openalex.org/I157485424"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5033788275"],"corresponding_institution_ids":["https://openalex.org/I157485424"],"apc_list":null,"apc_paid":null,"fwci":1.1837,"has_fulltext":false,"cited_by_count":26,"citation_normalized_percentile":{"value":0.82259067,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":98},"biblio":{"volume":"2015","issue":null,"first_page":"1707","last_page":"1710"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9958999752998352,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14189","display_name":"Intravenous Infusion Technology and Safety","score":0.9876000285148621,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electrical-impedance-tomography","display_name":"Electrical impedance tomography","score":0.9547443389892578},{"id":"https://openalex.org/keywords/wearable-computer","display_name":"Wearable computer","score":0.7425440549850464},{"id":"https://openalex.org/keywords/electrical-impedance","display_name":"Electrical impedance","score":0.5687215328216553},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4878551959991455},{"id":"https://openalex.org/keywords/planar","display_name":"Planar","score":0.41456273198127747},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.392347514629364},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.38182738423347473},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.33433768153190613},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.2630680799484253},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.18739482760429382},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.1716172993183136}],"concepts":[{"id":"https://openalex.org/C155175808","wikidata":"https://www.wikidata.org/wiki/Q1326472","display_name":"Electrical impedance tomography","level":3,"score":0.9547443389892578},{"id":"https://openalex.org/C150594956","wikidata":"https://www.wikidata.org/wiki/Q1334829","display_name":"Wearable computer","level":2,"score":0.7425440549850464},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.5687215328216553},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4878551959991455},{"id":"https://openalex.org/C134786449","wikidata":"https://www.wikidata.org/wiki/Q3391255","display_name":"Planar","level":2,"score":0.41456273198127747},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.392347514629364},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.38182738423347473},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.33433768153190613},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2630680799484253},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.18739482760429382},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1716172993183136},{"id":"https://openalex.org/C121684516","wikidata":"https://www.wikidata.org/wiki/Q7600677","display_name":"Computer graphics (images)","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D004566","descriptor_name":"Electrodes","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004566","descriptor_name":"Electrodes","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004566","descriptor_name":"Electrodes","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008168","descriptor_name":"Lung","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D008168","descriptor_name":"Lung","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D008168","descriptor_name":"Lung","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D013990","descriptor_name":"Tidal Volume","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D013990","descriptor_name":"Tidal Volume","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D013990","descriptor_name":"Tidal Volume","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D014057","descriptor_name":"Tomography, X-Ray Computed","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D014057","descriptor_name":"Tomography, X-Ray Computed","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D014057","descriptor_name":"Tomography, X-Ray Computed","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059629","descriptor_name":"Signal-To-Noise Ratio","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059629","descriptor_name":"Signal-To-Noise Ratio","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059629","descriptor_name":"Signal-To-Noise Ratio","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/embc.2015.7318706","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2015.7318706","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},{"id":"pmid:26736606","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/26736606","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Good health and well-being","score":0.4399999976158142,"id":"https://metadata.un.org/sdg/3"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W1978238763","https://openalex.org/W2009786158","https://openalex.org/W2020733548","https://openalex.org/W2062689759","https://openalex.org/W2095886535","https://openalex.org/W2097353049","https://openalex.org/W2897807752","https://openalex.org/W4248740079"],"related_works":["https://openalex.org/W2593522389","https://openalex.org/W2280313370","https://openalex.org/W2942774083","https://openalex.org/W3206007013","https://openalex.org/W2857059523","https://openalex.org/W2980294257","https://openalex.org/W2932327628","https://openalex.org/W1999111348","https://openalex.org/W2790871116","https://openalex.org/W3081677400","https://openalex.org/W2842325558","https://openalex.org/W3095259089","https://openalex.org/W2078121397","https://openalex.org/W2625382644","https://openalex.org/W3092827489","https://openalex.org/W2029889946","https://openalex.org/W2026033563","https://openalex.org/W2380683879","https://openalex.org/W2013822067","https://openalex.org/W90849762"],"abstract_inverted_index":{"The":[0,13,37,55,110,128],"wearable":[1,112],"lung-health":[2,119],"monitoring":[3,120],"system":[4,15,113,130],"is":[5,22,45,58,131],"proposed":[6,14,111,129],"with":[7,24,73],"an":[8,94],"electrical":[9],"impedance":[10,53],"tomography":[11],"(EIT).":[12],"has":[16],"light":[17],"belt-type":[18],"form":[19],"factor":[20],"which":[21,44,121],"implemented":[23,133],"the":[25,31,49,61,65,80,84,97,115],"EIT":[26,38,67,82],"integrated":[27],"circuit":[28,33],"(IC)":[29],"on":[30,136],"planar-fashionable":[32],"board":[34],"(P-FCB)":[35],"technology.":[36],"IC":[39],"provides":[40],"programmable":[41],"current":[42],"stimulation":[43],"optimally":[46],"controlled":[47],"by":[48],"results":[50],"of":[51,96],"contact":[52],"monitoring.":[54],"measured":[56,85],"data":[57],"transmitted":[59],"to":[60,75,106],"mobile":[62],"device":[63],"and":[64,71,99,134,139],"lung":[66,81,86,108],"images":[68],"are":[69],"reconstructed":[70],"displayed":[72],"up":[74],"20":[76],"frames/s":[77],"real-time.":[78],"From":[79],"image,":[83],"air":[87],"volume":[88],"ratio":[89],"can":[90,103,122],"be":[91,104,123],"used":[92,124],"as":[93],"indicator":[95],"lung-health,":[98],"other":[100],"various":[101],"parameters":[102],"extracted":[105],"monitor":[107],"status.":[109],"achieves":[114],"user":[116],"convenience":[117],"for":[118],"personally":[125],"at":[126],"home.":[127],"fully":[132],"verified":[135],"both":[137],"in-vitro":[138],"in-vivo":[140],"tests.":[141]},"counts_by_year":[{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":5},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":4},{"year":2020,"cited_by_count":4},{"year":2019,"cited_by_count":2},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":3},{"year":2016,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
