{"id":"https://openalex.org/W2316197520","doi":"https://doi.org/10.1109/embc.2014.6943653","title":"Wearable depression monitoring system with heart-rate variability","display_name":"Wearable depression monitoring system with heart-rate variability","publication_year":2014,"publication_date":"2014-08-01","ids":{"openalex":"https://openalex.org/W2316197520","doi":"https://doi.org/10.1109/embc.2014.6943653","mag":"2316197520","pmid":"https://pubmed.ncbi.nlm.nih.gov/25570021"},"language":"en","primary_location":{"id":"doi:10.1109/embc.2014.6943653","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2014.6943653","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5074581360","display_name":"Taehwan Roh","orcid":"https://orcid.org/0000-0003-0312-6170"},"institutions":[{"id":"https://openalex.org/I157485424","display_name":"Korea Advanced Institute of Science and Technology","ror":"https://ror.org/05apxxy63","country_code":"KR","type":"education","lineage":["https://openalex.org/I157485424"]}],"countries":["KR"],"is_corresponding":true,"raw_author_name":"Taehwan Roh","raw_affiliation_strings":["Korean Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korean"],"affiliations":[{"raw_affiliation_string":"Korean Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korean","institution_ids":["https://openalex.org/I157485424"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5033788275","display_name":"Sunjoo Hong","orcid":null},"institutions":[{"id":"https://openalex.org/I157485424","display_name":"Korea Advanced Institute of Science and Technology","ror":"https://ror.org/05apxxy63","country_code":"KR","type":"education","lineage":["https://openalex.org/I157485424"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Sunjoo Hong","raw_affiliation_strings":["Korean Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korean"],"affiliations":[{"raw_affiliation_string":"Korean Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korean","institution_ids":["https://openalex.org/I157485424"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5077896259","display_name":"Hoi\u2010Jun Yoo","orcid":"https://orcid.org/0000-0002-6661-4879"},"institutions":[{"id":"https://openalex.org/I157485424","display_name":"Korea Advanced Institute of Science and Technology","ror":"https://ror.org/05apxxy63","country_code":"KR","type":"education","lineage":["https://openalex.org/I157485424"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Hoi-Jun Yoo","raw_affiliation_strings":["Korean Advanced Institute of Science and Technology (KAIST), 373-1, Guseong-dong, Yuseong-gu, Daejeon, 305-701, Republic of Korean"],"affiliations":[{"raw_affiliation_string":"Korean Advanced Institute of Science and Technology (KAIST), 373-1, Guseong-dong, Yuseong-gu, Daejeon, 305-701, Republic of Korean","institution_ids":["https://openalex.org/I157485424"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5074581360"],"corresponding_institution_ids":["https://openalex.org/I157485424"],"apc_list":null,"apc_paid":null,"fwci":0.5926,"has_fulltext":false,"cited_by_count":37,"citation_normalized_percentile":{"value":0.73698425,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":99},"biblio":{"volume":"2014","issue":null,"first_page":"562","last_page":"565"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.9912999868392944,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.9912999868392944,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9686999917030334,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.965499997138977,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/wearable-computer","display_name":"Wearable computer","score":0.7452613115310669},{"id":"https://openalex.org/keywords/bluetooth","display_name":"Bluetooth","score":0.6723940968513489},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6393600702285767},{"id":"https://openalex.org/keywords/bluetooth-low-energy","display_name":"Bluetooth Low Energy","score":0.5547201633453369},{"id":"https://openalex.org/keywords/interfacing","display_name":"Interfacing","score":0.5466395616531372},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.4734054505825043},{"id":"https://openalex.org/keywords/system-on-a-chip","display_name":"System on a chip","score":0.4357059597969055},{"id":"https://openalex.org/keywords/heart-rate-variability","display_name":"Heart rate variability","score":0.43541428446769714},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.42353999614715576},{"id":"https://openalex.org/keywords/remote-patient-monitoring","display_name":"Remote patient monitoring","score":0.4191233515739441},{"id":"https://openalex.org/keywords/wearable-technology","display_name":"Wearable technology","score":0.41796547174453735},{"id":"https://openalex.org/keywords/computer-hardware","display_name":"Computer hardware","score":0.2810171842575073},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.2717921733856201},{"id":"https://openalex.org/keywords/heart-rate","display_name":"Heart rate","score":0.17963549494743347},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.17147931456565857},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.09819495677947998}],"concepts":[{"id":"https://openalex.org/C150594956","wikidata":"https://www.wikidata.org/wiki/Q1334829","display_name":"Wearable computer","level":2,"score":0.7452613115310669},{"id":"https://openalex.org/C546215728","wikidata":"https://www.wikidata.org/wiki/Q39531","display_name":"Bluetooth","level":3,"score":0.6723940968513489},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6393600702285767},{"id":"https://openalex.org/C2776418194","wikidata":"https://www.wikidata.org/wiki/Q1638779","display_name":"Bluetooth Low Energy","level":4,"score":0.5547201633453369},{"id":"https://openalex.org/C2776303644","wikidata":"https://www.wikidata.org/wiki/Q1020499","display_name":"Interfacing","level":2,"score":0.5466395616531372},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.4734054505825043},{"id":"https://openalex.org/C118021083","wikidata":"https://www.wikidata.org/wiki/Q610398","display_name":"System on a chip","level":2,"score":0.4357059597969055},{"id":"https://openalex.org/C71635504","wikidata":"https://www.wikidata.org/wiki/Q933954","display_name":"Heart rate variability","level":4,"score":0.43541428446769714},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.42353999614715576},{"id":"https://openalex.org/C175079658","wikidata":"https://www.wikidata.org/wiki/Q7312165","display_name":"Remote patient monitoring","level":2,"score":0.4191233515739441},{"id":"https://openalex.org/C54290928","wikidata":"https://www.wikidata.org/wiki/Q4845080","display_name":"Wearable technology","level":3,"score":0.41796547174453735},{"id":"https://openalex.org/C9390403","wikidata":"https://www.wikidata.org/wiki/Q3966","display_name":"Computer hardware","level":1,"score":0.2810171842575073},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.2717921733856201},{"id":"https://openalex.org/C2777953023","wikidata":"https://www.wikidata.org/wiki/Q1073121","display_name":"Heart rate","level":3,"score":0.17963549494743347},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.17147931456565857},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.09819495677947998},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.0},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D003863","descriptor_name":"Depression","qualifier_ui":"Q000503","qualifier_name":"physiopathology","is_major_topic":false},{"descriptor_ui":"D003863","descriptor_name":"Depression","qualifier_ui":"Q000503","qualifier_name":"physiopathology","is_major_topic":false},{"descriptor_ui":"D003863","descriptor_name":"Depression","qualifier_ui":"Q000503","qualifier_name":"physiopathology","is_major_topic":false},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006321","descriptor_name":"Heart","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006321","descriptor_name":"Heart","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006321","descriptor_name":"Heart","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006339","descriptor_name":"Heart Rate","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006339","descriptor_name":"Heart Rate","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006339","descriptor_name":"Heart Rate","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D059015","descriptor_name":"Wireless Technology","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059015","descriptor_name":"Wireless Technology","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059015","descriptor_name":"Wireless Technology","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D060388","descriptor_name":"Support Vector Machine","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D060388","descriptor_name":"Support Vector Machine","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D060388","descriptor_name":"Support Vector Machine","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/embc.2014.6943653","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2014.6943653","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},{"id":"pmid:25570021","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/25570021","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Good health and well-being","score":0.5199999809265137,"id":"https://metadata.un.org/sdg/3"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W1970717979","https://openalex.org/W2072454120","https://openalex.org/W2418957712","https://openalex.org/W6717161168"],"related_works":["https://openalex.org/W2136647108","https://openalex.org/W2350029007","https://openalex.org/W1965180958","https://openalex.org/W1973428399","https://openalex.org/W2182594080","https://openalex.org/W2484987020","https://openalex.org/W2152662857","https://openalex.org/W2017757432","https://openalex.org/W2966018205","https://openalex.org/W2316583557"],"abstract_inverted_index":{"A":[0],"wearable":[1,48],"depression":[2,100,112],"monitoring":[3,43],"system":[4,44,83],"is":[5,15,52,74,84],"proposed":[6],"with":[7,56,68,114],"an":[8],"application-specific":[9],"system-on-chip":[10],"(SoC)":[11],"solution.":[12],"The":[13],"SoC":[14,35],"designed":[16],"to":[17,33,86],"accelerate":[18],"the":[19,29,34,42,60,82,93,96,103,110],"filtering":[20],"and":[21,37,98,108],"feature":[22],"extraction":[23],"of":[24,95,116],"heart-rate":[25],"variability":[26],"(HRV)":[27],"from":[28],"electrocardiogram":[30],"(ECG).":[31],"Thanks":[32],"solution":[36],"planar-fashionable":[38],"circuit":[39],"board":[40],"(P-FCB),":[41],"becomes":[45],"a":[46],"low-power":[47],"system.":[49],"Its":[50],"dimension":[51],"14cm":[53],"\u00d7":[54],"7cm":[55],"5mm":[57],"thickness":[58],"covering":[59],"chest":[61],"band":[62],"for":[63],"convenient":[64],"usage.":[65],"In":[66],"addition,":[67],"3.7V":[69],"500mAh":[70],"battery,":[71],"its":[72],"lifetime":[73],"at":[75],"least":[76],"10":[77],"hours.":[78],"For":[79],"user's":[80,111],"convenience,":[81],"interfacing":[85],"smart":[87,104],"phones":[88],"through":[89],"Bluetooth":[90],"communication.":[91],"With":[92],"features":[94],"HRV":[97],"Beck":[99],"inventory":[101],"(BDI),":[102],"phone":[105],"application":[106],"trains":[107],"classifies":[109],"scale":[113],"71%":[115],"accuracy.":[117]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":4},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":6},{"year":2020,"cited_by_count":7},{"year":2019,"cited_by_count":4},{"year":2018,"cited_by_count":3},{"year":2017,"cited_by_count":1},{"year":2015,"cited_by_count":2}],"updated_date":"2026-04-03T22:45:19.894376","created_date":"2025-10-10T00:00:00"}
