{"id":"https://openalex.org/W2008169280","doi":"https://doi.org/10.1109/embc.2013.6610442","title":"An initial step towards improving the accuracy of the oscillometric blood pressure measurement","display_name":"An initial step towards improving the accuracy of the oscillometric blood pressure measurement","publication_year":2013,"publication_date":"2013-07-01","ids":{"openalex":"https://openalex.org/W2008169280","doi":"https://doi.org/10.1109/embc.2013.6610442","mag":"2008169280","pmid":"https://pubmed.ncbi.nlm.nih.gov/24110629"},"language":"en","primary_location":{"id":"doi:10.1109/embc.2013.6610442","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2013.6610442","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5007122935","display_name":"Jiankun Liu","orcid":"https://orcid.org/0000-0002-3064-8575"},"institutions":[{"id":"https://openalex.org/I87216513","display_name":"Michigan State University","ror":"https://ror.org/05hs6h993","country_code":"US","type":"education","lineage":["https://openalex.org/I87216513"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Jiankun Liu","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, USA","Dept. of Electr. & Comput. Eng., Michigan State Univ., East Lansing, MI, USA#TAB#"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, USA","institution_ids":["https://openalex.org/I87216513"]},{"raw_affiliation_string":"Dept. of Electr. & Comput. Eng., Michigan State Univ., East Lansing, MI, USA#TAB#","institution_ids":["https://openalex.org/I87216513"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5057276590","display_name":"Jin\u2010Oh Hahn","orcid":"https://orcid.org/0000-0001-5429-2836"},"institutions":[{"id":"https://openalex.org/I66946132","display_name":"University of Maryland, College Park","ror":"https://ror.org/047s2c258","country_code":"US","type":"education","lineage":["https://openalex.org/I66946132"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Jin-Oh Hahn","raw_affiliation_strings":["Department of Mechanical Engineering, University of Maryland, College Park, MD, USA","Dept. of Mech. Eng., Univ. of Maryland, College Park, MD, USA"],"affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, University of Maryland, College Park, MD, USA","institution_ids":["https://openalex.org/I66946132"]},{"raw_affiliation_string":"Dept. of Mech. Eng., Univ. of Maryland, College Park, MD, USA","institution_ids":["https://openalex.org/I66946132"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5076698656","display_name":"Ramakrishna Mukkamala","orcid":"https://orcid.org/0000-0001-8918-4050"},"institutions":[{"id":"https://openalex.org/I87216513","display_name":"Michigan State University","ror":"https://ror.org/05hs6h993","country_code":"US","type":"education","lineage":["https://openalex.org/I87216513"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ramakrishna Mukkamala","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, USA","Dept. of Electr. & Comput. Eng., Michigan State Univ., East Lansing, MI, USA#TAB#"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, USA","institution_ids":["https://openalex.org/I87216513"]},{"raw_affiliation_string":"Dept. of Electr. & Comput. Eng., Michigan State Univ., East Lansing, MI, USA#TAB#","institution_ids":["https://openalex.org/I87216513"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5007122935"],"corresponding_institution_ids":["https://openalex.org/I87216513"],"apc_list":null,"apc_paid":null,"fwci":0.3971,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.67262958,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"2013","issue":null,"first_page":"4082","last_page":"4085"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10144","display_name":"Blood Pressure and Hypertension Studies","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10144","display_name":"Blood Pressure and Hypertension Studies","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10924","display_name":"Cardiovascular Health and Disease Prevention","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/parametric-statistics","display_name":"Parametric statistics","score":0.7193797826766968},{"id":"https://openalex.org/keywords/waveform","display_name":"Waveform","score":0.7153061032295227},{"id":"https://openalex.org/keywords/cuff","display_name":"Cuff","score":0.6498134136199951},{"id":"https://openalex.org/keywords/blood-pressure","display_name":"Blood pressure","score":0.5865968465805054},{"id":"https://openalex.org/keywords/pressure-measurement","display_name":"Pressure measurement","score":0.5320696830749512},{"id":"https://openalex.org/keywords/parametric-model","display_name":"Parametric model","score":0.4970684349536896},{"id":"https://openalex.org/keywords/accuracy-and-precision","display_name":"Accuracy and precision","score":0.47008752822875977},{"id":"https://openalex.org/keywords/range","display_name":"Range (aeronautics)","score":0.4658554196357727},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4642556309700012},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.24877989292144775},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.20618870854377747},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.156818687915802},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.14435145258903503},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.10744971036911011},{"id":"https://openalex.org/keywords/surgery","display_name":"Surgery","score":0.09512707591056824},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.08852589130401611},{"id":"https://openalex.org/keywords/internal-medicine","display_name":"Internal medicine","score":0.08652663230895996},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.06907826662063599}],"concepts":[{"id":"https://openalex.org/C117251300","wikidata":"https://www.wikidata.org/wiki/Q1849855","display_name":"Parametric statistics","level":2,"score":0.7193797826766968},{"id":"https://openalex.org/C197424946","wikidata":"https://www.wikidata.org/wiki/Q1165717","display_name":"Waveform","level":3,"score":0.7153061032295227},{"id":"https://openalex.org/C2780017030","wikidata":"https://www.wikidata.org/wiki/Q368366","display_name":"Cuff","level":2,"score":0.6498134136199951},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.5865968465805054},{"id":"https://openalex.org/C80264047","wikidata":"https://www.wikidata.org/wiki/Q7424019","display_name":"Pressure measurement","level":2,"score":0.5320696830749512},{"id":"https://openalex.org/C24574437","wikidata":"https://www.wikidata.org/wiki/Q7135228","display_name":"Parametric model","level":3,"score":0.4970684349536896},{"id":"https://openalex.org/C202799725","wikidata":"https://www.wikidata.org/wiki/Q272035","display_name":"Accuracy and precision","level":2,"score":0.47008752822875977},{"id":"https://openalex.org/C204323151","wikidata":"https://www.wikidata.org/wiki/Q905424","display_name":"Range (aeronautics)","level":2,"score":0.4658554196357727},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4642556309700012},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.24877989292144775},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.20618870854377747},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.156818687915802},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.14435145258903503},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.10744971036911011},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.09512707591056824},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.08852589130401611},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.08652663230895996},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.06907826662063599},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.0},{"id":"https://openalex.org/C554190296","wikidata":"https://www.wikidata.org/wiki/Q47528","display_name":"Radar","level":2,"score":0.0}],"mesh":[{"descriptor_ui":"D001158","descriptor_name":"Arteries","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D001158","descriptor_name":"Arteries","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D001158","descriptor_name":"Arteries","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D001794","descriptor_name":"Blood Pressure","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D001794","descriptor_name":"Blood Pressure","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D001794","descriptor_name":"Blood Pressure","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D003971","descriptor_name":"Diastole","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D003971","descriptor_name":"Diastole","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D003971","descriptor_name":"Diastole","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008955","descriptor_name":"Models, Cardiovascular","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008955","descriptor_name":"Models, Cardiovascular","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008955","descriptor_name":"Models, Cardiovascular","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D009991","descriptor_name":"Oscillometry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D009991","descriptor_name":"Oscillometry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D009991","descriptor_name":"Oscillometry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D011312","descriptor_name":"Pressure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011312","descriptor_name":"Pressure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011312","descriptor_name":"Pressure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013599","descriptor_name":"Systole","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013599","descriptor_name":"Systole","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013599","descriptor_name":"Systole","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D058067","descriptor_name":"Wavelet Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D058067","descriptor_name":"Wavelet Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D058067","descriptor_name":"Wavelet Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/embc.2013.6610442","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2013.6610442","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},{"id":"pmid:24110629","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/24110629","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W1977471369","https://openalex.org/W2010608866","https://openalex.org/W2041420156","https://openalex.org/W2078601452","https://openalex.org/W2089218156","https://openalex.org/W2134042621"],"related_works":["https://openalex.org/W1987725374","https://openalex.org/W1974895211","https://openalex.org/W1790632686","https://openalex.org/W2985296909","https://openalex.org/W2399968241","https://openalex.org/W2888100659","https://openalex.org/W4289516467","https://openalex.org/W4288063552","https://openalex.org/W2066649872","https://openalex.org/W2082998112"],"abstract_inverted_index":{"We":[0],"conceived":[1],"a":[2,14,28,41,91],"set":[3],"of":[4,66],"physical":[5,29],"model-based":[6],"techniques":[7,68,97],"to":[8],"compute":[9],"blood":[10],"pressure":[11,18,23,82],"(BP)":[12],"from":[13,37,54],"standard":[15],"oscillometric":[16,88],"cuff":[17,22,81],"measurement.":[19],"First,":[20],"the":[21,32,38,48,55,64,70,103],"measurement":[24,39],"is":[25,52],"represented":[26],"with":[27,69,85],"model.":[30,57],"Then,":[31],"model":[33,89],"unknowns":[34],"are":[35],"determined":[36,56],"via":[40],"parametric,":[42],"non-parametric":[43],"or":[44],"hybrid":[45],"technique.":[46,105],"Finally,":[47],"entire":[49],"BP":[50],"waveform":[51],"computed":[53],"For":[58],"an":[59,86],"initial":[60],"assessment,":[61],"we":[62],"compared":[63],"accuracy":[65,101],"these":[67],"conventional":[71,104],"fixed-ratio":[72],"technique":[73],"for":[74],"computing":[75],"systolic":[76],"and":[77],"diastolic":[78],"pressures":[79],"using":[80],"measurements":[83],"simulated":[84],"established":[87],"over":[90],"wide":[92],"parameter":[93],"range.":[94],"The":[95],"new":[96],"afforded":[98],"much":[99],"greater":[100],"than":[102],"Our":[106],"future":[107],"efforts":[108],"will":[109],"focus":[110],"on":[111],"experimental":[112],"validation.":[113]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2014,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
