{"id":"https://openalex.org/W2013506527","doi":"https://doi.org/10.1109/embc.2013.6610296","title":"Experimental analysis of the performance of an air-powered needle-free liquid jet injector","display_name":"Experimental analysis of the performance of an air-powered needle-free liquid jet injector","publication_year":2013,"publication_date":"2013-07-01","ids":{"openalex":"https://openalex.org/W2013506527","doi":"https://doi.org/10.1109/embc.2013.6610296","mag":"2013506527","pmid":"https://pubmed.ncbi.nlm.nih.gov/24110483"},"language":"en","primary_location":{"id":"doi:10.1109/embc.2013.6610296","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2013.6610296","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5030249337","display_name":"Rocco Portaro","orcid":null},"institutions":[{"id":"https://openalex.org/I60158472","display_name":"Concordia University","ror":"https://ror.org/0420zvk78","country_code":"CA","type":"education","lineage":["https://openalex.org/I60158472"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Rocco Portaro","raw_affiliation_strings":["Department of Mechanical and Industrial Engineering, Concordia University, Montreal, Canada","Dept. of Mech. & Ind. Eng., Concordia Univ., Montreal, QC, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechanical and Industrial Engineering, Concordia University, Montreal, Canada","institution_ids":["https://openalex.org/I60158472"]},{"raw_affiliation_string":"Dept. of Mech. & Ind. Eng., Concordia Univ., Montreal, QC, Canada","institution_ids":["https://openalex.org/I60158472"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5057990641","display_name":"Hoi Dick Ng","orcid":"https://orcid.org/0000-0002-8459-5990"},"institutions":[{"id":"https://openalex.org/I60158472","display_name":"Concordia University","ror":"https://ror.org/0420zvk78","country_code":"CA","type":"education","lineage":["https://openalex.org/I60158472"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Hoi Dick Ng","raw_affiliation_strings":["Department of Mechanical and Industrial Engineering, Concordia University, Montreal, Canada","Dept. of Mech. & Ind. Eng., Concordia Univ., Montreal, QC, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechanical and Industrial Engineering, Concordia University, Montreal, Canada","institution_ids":["https://openalex.org/I60158472"]},{"raw_affiliation_string":"Dept. of Mech. & Ind. Eng., Concordia Univ., Montreal, QC, Canada","institution_ids":["https://openalex.org/I60158472"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I60158472"],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":"2013","issue":null,"first_page":"3499","last_page":"3502"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10412","display_name":"Microfluidic and Capillary Electrophoresis Applications","score":0.970300018787384,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10412","display_name":"Microfluidic and Capillary Electrophoresis Applications","score":0.970300018787384,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10553","display_name":"Combustion and flame dynamics","score":0.9304999709129333,"subfield":{"id":"https://openalex.org/subfields/2206","display_name":"Computational Mechanics"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14189","display_name":"Intravenous Infusion Technology and Safety","score":0.9298999905586243,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/injector","display_name":"Injector","score":0.8989982604980469},{"id":"https://openalex.org/keywords/nozzle","display_name":"Nozzle","score":0.8365810513496399},{"id":"https://openalex.org/keywords/stagnation-pressure","display_name":"Stagnation pressure","score":0.7412939071655273},{"id":"https://openalex.org/keywords/jet","display_name":"Jet (fluid)","score":0.6432467699050903},{"id":"https://openalex.org/keywords/mechanics","display_name":"Mechanics","score":0.6268306970596313},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.5817772150039673},{"id":"https://openalex.org/keywords/bar","display_name":"Bar (unit)","score":0.5171393752098083},{"id":"https://openalex.org/keywords/pressure-sensor","display_name":"Pressure sensor","score":0.493684858083725},{"id":"https://openalex.org/keywords/chamber-pressure","display_name":"Chamber pressure","score":0.48270225524902344},{"id":"https://openalex.org/keywords/stagnation-temperature","display_name":"Stagnation temperature","score":0.44589167833328247},{"id":"https://openalex.org/keywords/impact-pressure","display_name":"Impact pressure","score":0.4249614477157593},{"id":"https://openalex.org/keywords/spray-characteristics","display_name":"Spray characteristics","score":0.42438775300979614},{"id":"https://openalex.org/keywords/range","display_name":"Range (aeronautics)","score":0.42098402976989746},{"id":"https://openalex.org/keywords/mach-number","display_name":"Mach number","score":0.2681465744972229},{"id":"https://openalex.org/keywords/spray-nozzle","display_name":"Spray nozzle","score":0.24443891644477844},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.22826454043388367},{"id":"https://openalex.org/keywords/stagnation-point","display_name":"Stagnation point","score":0.20342737436294556},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.1667231023311615},{"id":"https://openalex.org/keywords/meteorology","display_name":"Meteorology","score":0.12491205334663391},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.1197710931301117},{"id":"https://openalex.org/keywords/composite-material","display_name":"Composite material","score":0.09808453917503357},{"id":"https://openalex.org/keywords/heat-transfer","display_name":"Heat transfer","score":0.06530463695526123}],"concepts":[{"id":"https://openalex.org/C135186712","wikidata":"https://www.wikidata.org/wiki/Q425705","display_name":"Injector","level":2,"score":0.8989982604980469},{"id":"https://openalex.org/C56200935","wikidata":"https://www.wikidata.org/wiki/Q250840","display_name":"Nozzle","level":2,"score":0.8365810513496399},{"id":"https://openalex.org/C86980398","wikidata":"https://www.wikidata.org/wiki/Q1043944","display_name":"Stagnation pressure","level":3,"score":0.7412939071655273},{"id":"https://openalex.org/C119947313","wikidata":"https://www.wikidata.org/wiki/Q5596635","display_name":"Jet (fluid)","level":2,"score":0.6432467699050903},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.6268306970596313},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5817772150039673},{"id":"https://openalex.org/C188721877","wikidata":"https://www.wikidata.org/wiki/Q103510","display_name":"Bar (unit)","level":2,"score":0.5171393752098083},{"id":"https://openalex.org/C41325743","wikidata":"https://www.wikidata.org/wiki/Q1261040","display_name":"Pressure sensor","level":2,"score":0.493684858083725},{"id":"https://openalex.org/C2777859621","wikidata":"https://www.wikidata.org/wiki/Q17086736","display_name":"Chamber pressure","level":2,"score":0.48270225524902344},{"id":"https://openalex.org/C136387016","wikidata":"https://www.wikidata.org/wiki/Q1119919","display_name":"Stagnation temperature","level":4,"score":0.44589167833328247},{"id":"https://openalex.org/C73225119","wikidata":"https://www.wikidata.org/wiki/Q17098114","display_name":"Impact pressure","level":2,"score":0.4249614477157593},{"id":"https://openalex.org/C190894226","wikidata":"https://www.wikidata.org/wiki/Q7580227","display_name":"Spray characteristics","level":4,"score":0.42438775300979614},{"id":"https://openalex.org/C204323151","wikidata":"https://www.wikidata.org/wiki/Q905424","display_name":"Range (aeronautics)","level":2,"score":0.42098402976989746},{"id":"https://openalex.org/C165231844","wikidata":"https://www.wikidata.org/wiki/Q160669","display_name":"Mach number","level":2,"score":0.2681465744972229},{"id":"https://openalex.org/C116705413","wikidata":"https://www.wikidata.org/wiki/Q2167111","display_name":"Spray nozzle","level":3,"score":0.24443891644477844},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.22826454043388367},{"id":"https://openalex.org/C9715774","wikidata":"https://www.wikidata.org/wiki/Q651142","display_name":"Stagnation point","level":3,"score":0.20342737436294556},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.1667231023311615},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.12491205334663391},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1197710931301117},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.09808453917503357},{"id":"https://openalex.org/C50517652","wikidata":"https://www.wikidata.org/wiki/Q179635","display_name":"Heat transfer","level":2,"score":0.06530463695526123}],"mesh":[{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007277","descriptor_name":"Injections, Jet","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D007277","descriptor_name":"Injections, Jet","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D007277","descriptor_name":"Injections, Jet","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D011312","descriptor_name":"Pressure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011312","descriptor_name":"Pressure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011312","descriptor_name":"Pressure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D016503","descriptor_name":"Drug Delivery Systems","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D016503","descriptor_name":"Drug Delivery Systems","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D016503","descriptor_name":"Drug Delivery Systems","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/embc.2013.6610296","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2013.6610296","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","raw_type":"proceedings-article"},{"id":"pmid:24110483","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/24110483","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.7699999809265137,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":22,"referenced_works":["https://openalex.org/W94189062","https://openalex.org/W1518056733","https://openalex.org/W2014563914","https://openalex.org/W2021305263","https://openalex.org/W2030363631","https://openalex.org/W2036125917","https://openalex.org/W2041845920","https://openalex.org/W2047353849","https://openalex.org/W2052818607","https://openalex.org/W2058789310","https://openalex.org/W2085068888","https://openalex.org/W2098396485","https://openalex.org/W2104361764","https://openalex.org/W2109670216","https://openalex.org/W2117885961","https://openalex.org/W2161983664","https://openalex.org/W2167725577","https://openalex.org/W2319332384","https://openalex.org/W2536707049","https://openalex.org/W2557791717","https://openalex.org/W2807950599","https://openalex.org/W6684578767"],"related_works":["https://openalex.org/W1571451260","https://openalex.org/W284105848","https://openalex.org/W2046554525","https://openalex.org/W2076184996","https://openalex.org/W1490730177","https://openalex.org/W2626300658","https://openalex.org/W1559573650","https://openalex.org/W1510287420","https://openalex.org/W3200658645","https://openalex.org/W340383805"],"abstract_inverted_index":{"An":[0],"experimental":[1],"study":[2,25],"was":[3,40,51,69,119,126],"performed":[4],"using":[5,26,53],"a":[6,54,61],"custom-built":[7],"air-powered":[8],"needle-free":[9],"injector":[10,15],"to":[11,37],"investigate":[12],"the":[13,18,48,73,78,88,93,99,110],"various":[14,64],"parameters":[16,65],"governing":[17],"dynamics":[19],"of":[20,47,63],"jet":[21,50],"injection.":[22],"A":[23],"parametric":[24],"five":[27],"different":[28],"nozzle":[29,95],"sizes":[30],"at":[31],"driver":[32,74,100],"pressure":[33,46,75,83,101],"ranging":[34],"from":[35],"4":[36],"8":[38],"bar":[39],"carried":[41],"out.":[42],"The":[43,116],"fluid":[44],"stagnation":[45,82,114,132],"liquid":[49],"determined":[52,70],"Honeywell":[55],"force":[56],"sensor.":[57],"Performance":[58],"plots":[59],"as":[60,72],"function":[62],"were":[66],"constructed.":[67],"It":[68],"that":[71],"increased":[76,84],"both":[77],"peak":[79,111,129],"and":[80,122],"average":[81,113,131],"almost":[85],"linearly":[86],"within":[87],"operating":[89],"range":[90],"considered.":[91],"Varying":[92],"injection":[94],"diameter,":[96],"whilst":[97],"keeping":[98],"constant":[102],"did":[103],"not":[104],"have":[105],"any":[106],"significant":[107,124],"impact":[108],"on":[109,128],"or":[112,130],"pressure.":[115,133],"chamber":[117],"length":[118],"also":[120],"varied":[121],"no":[123],"influence":[125],"found":[127]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2015,"cited_by_count":1}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2016-06-24T00:00:00"}
