{"id":"https://openalex.org/W2176395472","doi":"https://doi.org/10.1109/embc.2012.6347126","title":"Multi-channel optical sensor-array for measuring ballistocardiograms and respiratory activity in bed","display_name":"Multi-channel optical sensor-array for measuring ballistocardiograms and respiratory activity in bed","publication_year":2012,"publication_date":"2012-08-01","ids":{"openalex":"https://openalex.org/W2176395472","doi":"https://doi.org/10.1109/embc.2012.6347126","mag":"2176395472","pmid":"https://pubmed.ncbi.nlm.nih.gov/23367061"},"language":"en","primary_location":{"id":"doi:10.1109/embc.2012.6347126","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2012.6347126","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5052057571","display_name":"Christoph Br\u00fcser","orcid":null},"institutions":[{"id":"https://openalex.org/I887968799","display_name":"RWTH Aachen University","ror":"https://ror.org/04xfq0f34","country_code":"DE","type":"education","lineage":["https://openalex.org/I887968799"]},{"id":"https://openalex.org/I4210162505","display_name":"Philips (Germany)","ror":"https://ror.org/05san5604","country_code":"DE","type":"company","lineage":["https://openalex.org/I4210122849","https://openalex.org/I4210162505"]}],"countries":["DE"],"is_corresponding":true,"raw_author_name":"C. Bruser","raw_affiliation_strings":["Philips Chair for Medical Information Technology, RWTH Aachen University, Aachen, Germany. brueser@hia.rwth-aachen.de","Philips Chair for Medical Information Technology, RWTH Aachen University, Aachen, Germany"],"affiliations":[{"raw_affiliation_string":"Philips Chair for Medical Information Technology, RWTH Aachen University, Aachen, Germany. brueser@hia.rwth-aachen.de","institution_ids":["https://openalex.org/I887968799"]},{"raw_affiliation_string":"Philips Chair for Medical Information Technology, RWTH Aachen University, Aachen, Germany","institution_ids":["https://openalex.org/I887968799","https://openalex.org/I4210162505"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5044975358","display_name":"Anna Kerekes","orcid":null},"institutions":[{"id":"https://openalex.org/I4210162505","display_name":"Philips (Germany)","ror":"https://ror.org/05san5604","country_code":"DE","type":"company","lineage":["https://openalex.org/I4210122849","https://openalex.org/I4210162505"]},{"id":"https://openalex.org/I887968799","display_name":"RWTH Aachen University","ror":"https://ror.org/04xfq0f34","country_code":"DE","type":"education","lineage":["https://openalex.org/I887968799"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"A. Kerekes","raw_affiliation_strings":["Philips Chair for Medical Information Technology, RWTH Aachen University, Aachen, Germany"],"affiliations":[{"raw_affiliation_string":"Philips Chair for Medical Information Technology, RWTH Aachen University, Aachen, Germany","institution_ids":["https://openalex.org/I887968799","https://openalex.org/I4210162505"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101400733","display_name":"Stefan Winter","orcid":"https://orcid.org/0000-0001-8244-995X"},"institutions":[{"id":"https://openalex.org/I4210162505","display_name":"Philips (Germany)","ror":"https://ror.org/05san5604","country_code":"DE","type":"company","lineage":["https://openalex.org/I4210122849","https://openalex.org/I4210162505"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"S. Winter","raw_affiliation_strings":["Philips Technologie GmbH Innovative Technologies, Research Laboratories Company Limited, Aachen, Germany"],"affiliations":[{"raw_affiliation_string":"Philips Technologie GmbH Innovative Technologies, Research Laboratories Company Limited, Aachen, Germany","institution_ids":["https://openalex.org/I4210162505"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5060021065","display_name":"Steffen Leonhardt","orcid":"https://orcid.org/0000-0002-6898-6887"},"institutions":[{"id":"https://openalex.org/I4210162505","display_name":"Philips (Germany)","ror":"https://ror.org/05san5604","country_code":"DE","type":"company","lineage":["https://openalex.org/I4210122849","https://openalex.org/I4210162505"]},{"id":"https://openalex.org/I887968799","display_name":"RWTH Aachen University","ror":"https://ror.org/04xfq0f34","country_code":"DE","type":"education","lineage":["https://openalex.org/I887968799"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"S. Leonhardt","raw_affiliation_strings":["Philips Chair for Medical Information Technology, RWTH Aachen University, Aachen, Germany"],"affiliations":[{"raw_affiliation_string":"Philips Chair for Medical Information Technology, RWTH Aachen University, Aachen, Germany","institution_ids":["https://openalex.org/I887968799","https://openalex.org/I4210162505"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5052057571"],"corresponding_institution_ids":["https://openalex.org/I4210162505","https://openalex.org/I887968799"],"apc_list":null,"apc_paid":null,"fwci":2.6938,"has_fulltext":false,"cited_by_count":43,"citation_normalized_percentile":{"value":0.8977136,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":99},"biblio":{"volume":"2012","issue":null,"first_page":"5042","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.9977999925613403,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ballistocardiography","display_name":"Ballistocardiography","score":0.7661766409873962},{"id":"https://openalex.org/keywords/heart-beat","display_name":"Heart beat","score":0.6326687335968018},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.5672196745872498},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5487032532691956},{"id":"https://openalex.org/keywords/beat","display_name":"Beat (acoustics)","score":0.5210251808166504},{"id":"https://openalex.org/keywords/respiratory-rate","display_name":"Respiratory rate","score":0.48040059208869934},{"id":"https://openalex.org/keywords/vibration","display_name":"Vibration","score":0.4735901951789856},{"id":"https://openalex.org/keywords/signal-processing","display_name":"Signal processing","score":0.45456910133361816},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.4533781409263611},{"id":"https://openalex.org/keywords/signal","display_name":"SIGNAL (programming language)","score":0.42209142446517944},{"id":"https://openalex.org/keywords/channel","display_name":"Channel (broadcasting)","score":0.4210956394672394},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.40769538283348083},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.40508902072906494},{"id":"https://openalex.org/keywords/heart-rate","display_name":"Heart rate","score":0.337232768535614},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3066825866699219},{"id":"https://openalex.org/keywords/computer-hardware","display_name":"Computer hardware","score":0.16933971643447876},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.15783408284187317},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.15214574337005615},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.11432766914367676},{"id":"https://openalex.org/keywords/digital-signal-processing","display_name":"Digital signal processing","score":0.08023661375045776}],"concepts":[{"id":"https://openalex.org/C2779611634","wikidata":"https://www.wikidata.org/wiki/Q4851812","display_name":"Ballistocardiography","level":2,"score":0.7661766409873962},{"id":"https://openalex.org/C2982892191","wikidata":"https://www.wikidata.org/wiki/Q253408","display_name":"Heart beat","level":2,"score":0.6326687335968018},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.5672196745872498},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5487032532691956},{"id":"https://openalex.org/C189809214","wikidata":"https://www.wikidata.org/wiki/Q829522","display_name":"Beat (acoustics)","level":2,"score":0.5210251808166504},{"id":"https://openalex.org/C8213797","wikidata":"https://www.wikidata.org/wiki/Q754250","display_name":"Respiratory rate","level":4,"score":0.48040059208869934},{"id":"https://openalex.org/C198394728","wikidata":"https://www.wikidata.org/wiki/Q3695508","display_name":"Vibration","level":2,"score":0.4735901951789856},{"id":"https://openalex.org/C104267543","wikidata":"https://www.wikidata.org/wiki/Q208163","display_name":"Signal processing","level":3,"score":0.45456910133361816},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.4533781409263611},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.42209142446517944},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.4210956394672394},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.40769538283348083},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.40508902072906494},{"id":"https://openalex.org/C2777953023","wikidata":"https://www.wikidata.org/wiki/Q1073121","display_name":"Heart rate","level":3,"score":0.337232768535614},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3066825866699219},{"id":"https://openalex.org/C9390403","wikidata":"https://www.wikidata.org/wiki/Q3966","display_name":"Computer hardware","level":1,"score":0.16933971643447876},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.15783408284187317},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.15214574337005615},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.11432766914367676},{"id":"https://openalex.org/C84462506","wikidata":"https://www.wikidata.org/wiki/Q173142","display_name":"Digital signal processing","level":2,"score":0.08023661375045776},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D001450","descriptor_name":"Ballistocardiography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D001450","descriptor_name":"Ballistocardiography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D001450","descriptor_name":"Ballistocardiography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D001513","descriptor_name":"Beds","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D001513","descriptor_name":"Beds","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D001513","descriptor_name":"Beds","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006339","descriptor_name":"Heart Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006339","descriptor_name":"Heart Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006339","descriptor_name":"Heart Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015656","descriptor_name":"Respiratory Mechanics","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D015656","descriptor_name":"Respiratory Mechanics","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D015656","descriptor_name":"Respiratory Mechanics","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D018670","descriptor_name":"Monitoring, Ambulatory","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D018670","descriptor_name":"Monitoring, Ambulatory","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D018670","descriptor_name":"Monitoring, Ambulatory","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D055617","descriptor_name":"Micro-Electrical-Mechanical Systems","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D055617","descriptor_name":"Micro-Electrical-Mechanical Systems","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D055617","descriptor_name":"Micro-Electrical-Mechanical Systems","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D056152","descriptor_name":"Respiratory Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D056152","descriptor_name":"Respiratory Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D056152","descriptor_name":"Respiratory Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false}],"locations_count":3,"locations":[{"id":"doi:10.1109/embc.2012.6347126","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2012.6347126","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},{"id":"pmid:23367061","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/23367061","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null},{"id":"pmh:oai:publications.rwth-aachen.de:207858","is_oa":false,"landing_page_url":"http://publications.rwth-aachen.de/record/207858","pdf_url":null,"source":{"id":"https://openalex.org/S4306401362","display_name":"RWTH Publications (RWTH Aachen)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I887968799","host_organization_name":"RWTH Aachen University","host_organization_lineage":["https://openalex.org/I887968799"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"2012 annual international conference of the IEEE Engineering in Medicine and Biology Society : (EMBC 2012) ; San Diego, California, USA, 28 August - 1 September 2012. EMBC ; 34<br/>2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2012, San Diego, CA, USA, 2012-08-28 - 2012-09-01","raw_type":"info:eu-repo/semantics/publishedVersion"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","display_name":"Good health and well-being","score":0.41999998688697815}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W1973939185","https://openalex.org/W2002741442","https://openalex.org/W2013309032","https://openalex.org/W2056344526","https://openalex.org/W2078126533","https://openalex.org/W2107203001","https://openalex.org/W2120559736","https://openalex.org/W2123418885","https://openalex.org/W2137619789","https://openalex.org/W2142577541","https://openalex.org/W2152754400","https://openalex.org/W2167130514","https://openalex.org/W2168752508"],"related_works":["https://openalex.org/W2997872843","https://openalex.org/W1986527245","https://openalex.org/W2219888481","https://openalex.org/W2118200309","https://openalex.org/W2176395472","https://openalex.org/W2133293918","https://openalex.org/W2023821804","https://openalex.org/W2071576346","https://openalex.org/W2754264657","https://openalex.org/W1977904507"],"abstract_inverted_index":{"Our":[0,78],"work":[1],"covers":[2],"improvements":[3],"in":[4],"sensors":[5,44],"and":[6,58],"signal":[7],"processing":[8],"for":[9,27],"unobtrusive,":[10],"long-term":[11],"monitoring":[12,30],"of":[13,31,36,39,105],"cardiac":[14],"(and":[15],"respiratory)":[16],"rhythms":[17],"using":[18],"only":[19],"non-invasive":[20],"vibration":[21],"sensors.":[22],"We":[23],"describe":[24],"a":[25,47,66,73],"system":[26,64,70,87],"the":[28,54,83,90,103],"unobtrusive":[29],"vital":[32],"signs":[33],"by":[34],"means":[35],"an":[37],"array":[38],"novel":[40],"optical":[41,85],"ballistocardiography":[42],"(BCG)":[43],"placed":[45],"underneath":[46],"regular":[48],"bed":[49],"mattress.":[50],"Furthermore,":[51],"we":[52],"analyze":[53],"systems":[55],"spatial":[56],"sensitivity":[57],"present":[59],"proof-of-concept":[60],"results":[61,80],"comparing":[62],"our":[63],"to":[65,92],"more":[67,106],"conventional":[68],"BCG":[69],"based":[71],"on":[72],"single":[74],"electromechanical-film":[75],"(EMFi)":[76],"sensor.":[77],"preliminary":[79],"suggest":[81],"that":[82],"proposed":[84],"multi-channel":[86],"could":[88],"have":[89],"potential":[91],"reduce":[93],"beat-to-beat":[94],"heart":[95],"rate":[96],"estimation":[97],"errors,":[98],"as":[99,101],"well":[100],"enable":[102],"analysis":[104],"complex":[107],"breathing":[108],"patterns.":[109]},"counts_by_year":[{"year":2024,"cited_by_count":5},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":8},{"year":2019,"cited_by_count":4},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":4},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":5},{"year":2014,"cited_by_count":5},{"year":2013,"cited_by_count":3}],"updated_date":"2026-04-04T16:13:02.066488","created_date":"2025-10-10T00:00:00"}
