{"id":"https://openalex.org/W2058695656","doi":"https://doi.org/10.1109/embc.2012.6346967","title":"Low-power system-on-chip implementation for respiratory rate detection and transmission","display_name":"Low-power system-on-chip implementation for respiratory rate detection and transmission","publication_year":2012,"publication_date":"2012-08-01","ids":{"openalex":"https://openalex.org/W2058695656","doi":"https://doi.org/10.1109/embc.2012.6346967","mag":"2058695656","pmid":"https://pubmed.ncbi.nlm.nih.gov/23366928"},"language":"en","primary_location":{"id":"doi:10.1109/embc.2012.6346967","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2012.6346967","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5002729237","display_name":"Bryson Padasdao","orcid":"https://orcid.org/0000-0001-8065-8280"},"institutions":[{"id":"https://openalex.org/I117965899","display_name":"University of Hawai\u02bbi at M\u0101noa","ror":"https://ror.org/01wspgy28","country_code":"US","type":"education","lineage":["https://openalex.org/I117965899"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"B. Padasdao","raw_affiliation_strings":["University of Hawaii at Manoa, Honolulu, HI 96822, USA. brysonep@hawaii.edu","University of Hawaii at Manoa, Honolulu 96822, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Hawaii at Manoa, Honolulu, HI 96822, USA. brysonep@hawaii.edu","institution_ids":["https://openalex.org/I117965899"]},{"raw_affiliation_string":"University of Hawaii at Manoa, Honolulu 96822, USA","institution_ids":["https://openalex.org/I117965899"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5011692617","display_name":"Ruby Yee","orcid":"https://orcid.org/0009-0005-8590-4467"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"R. Yee","raw_affiliation_strings":["Pronk Technologies, Inc., Honolulu, USA","Pronk Technologies, Inc., Honolulu, 96826 USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Pronk Technologies, Inc., Honolulu, USA","institution_ids":[]},{"raw_affiliation_string":"Pronk Technologies, Inc., Honolulu, 96826 USA","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5080653289","display_name":"Olga Bori\u0107-Lubecke","orcid":"https://orcid.org/0000-0003-2877-7359"},"institutions":[{"id":"https://openalex.org/I117965899","display_name":"University of Hawai\u02bbi at M\u0101noa","ror":"https://ror.org/01wspgy28","country_code":"US","type":"education","lineage":["https://openalex.org/I117965899"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"O. Boric-Lubecke","raw_affiliation_strings":["Department of Electrical Engineering, University of Hawaii at Manoa, Honolulu, USA","Department of Electrical Engineering at the University of Hawaii at Manoa, Honolulu 96822 USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, University of Hawaii at Manoa, Honolulu, USA","institution_ids":["https://openalex.org/I117965899"]},{"raw_affiliation_string":"Department of Electrical Engineering at the University of Hawaii at Manoa, Honolulu 96822 USA","institution_ids":["https://openalex.org/I117965899"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":"2012","issue":null,"first_page":"4501","last_page":"4504"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11230","display_name":"Innovative Energy Harvesting Technologies","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11230","display_name":"Innovative Energy Harvesting Technologies","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11392","display_name":"Energy Harvesting in Wireless Networks","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":0.9944000244140625,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6023864150047302},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.5829483270645142},{"id":"https://openalex.org/keywords/power-consumption","display_name":"Power consumption","score":0.5367010831832886},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.5279523134231567},{"id":"https://openalex.org/keywords/chip","display_name":"Chip","score":0.5025348663330078},{"id":"https://openalex.org/keywords/comparator","display_name":"Comparator","score":0.4482557475566864},{"id":"https://openalex.org/keywords/battery","display_name":"Battery (electricity)","score":0.4429715871810913},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.43394798040390015},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.4296719431877136},{"id":"https://openalex.org/keywords/power-transmission","display_name":"Power transmission","score":0.41286972165107727},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.4022224247455597},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.38504132628440857},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.28054919838905334},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.23440220952033997},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.21853956580162048},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.21836352348327637}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6023864150047302},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.5829483270645142},{"id":"https://openalex.org/C2984118289","wikidata":"https://www.wikidata.org/wiki/Q29954","display_name":"Power consumption","level":3,"score":0.5367010831832886},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5279523134231567},{"id":"https://openalex.org/C165005293","wikidata":"https://www.wikidata.org/wiki/Q1074500","display_name":"Chip","level":2,"score":0.5025348663330078},{"id":"https://openalex.org/C155745195","wikidata":"https://www.wikidata.org/wiki/Q1164179","display_name":"Comparator","level":3,"score":0.4482557475566864},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.4429715871810913},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.43394798040390015},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.4296719431877136},{"id":"https://openalex.org/C92018576","wikidata":"https://www.wikidata.org/wiki/Q3242194","display_name":"Power transmission","level":3,"score":0.41286972165107727},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.4022224247455597},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.38504132628440857},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.28054919838905334},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.23440220952033997},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.21853956580162048},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.21836352348327637},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D003936","descriptor_name":"Diagnosis, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D003936","descriptor_name":"Diagnosis, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D003936","descriptor_name":"Diagnosis, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011211","descriptor_name":"Electric Power Supplies","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011211","descriptor_name":"Electric Power Supplies","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011211","descriptor_name":"Electric Power Supplies","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D013147","descriptor_name":"Spirometry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D013147","descriptor_name":"Spirometry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D013147","descriptor_name":"Spirometry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D018670","descriptor_name":"Monitoring, Ambulatory","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D018670","descriptor_name":"Monitoring, Ambulatory","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D018670","descriptor_name":"Monitoring, Ambulatory","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D056152","descriptor_name":"Respiratory Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D056152","descriptor_name":"Respiratory Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D056152","descriptor_name":"Respiratory Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D059015","descriptor_name":"Wireless Technology","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D059015","descriptor_name":"Wireless Technology","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D059015","descriptor_name":"Wireless Technology","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/embc.2012.6346967","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2012.6346967","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},{"id":"pmid:23366928","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/23366928","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.9100000262260437,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W2044057778","https://openalex.org/W2097721391","https://openalex.org/W2131731237","https://openalex.org/W2161287031"],"related_works":["https://openalex.org/W2034349229","https://openalex.org/W4366783034","https://openalex.org/W1972415042","https://openalex.org/W4313221225","https://openalex.org/W2150642609","https://openalex.org/W2005410346","https://openalex.org/W4306816370","https://openalex.org/W2189390720","https://openalex.org/W2390229089","https://openalex.org/W2951548045"],"abstract_inverted_index":{"Recent":[0],"biosensors":[1],"can":[2,19,50],"measure":[3],"respiratory":[4,37,52],"rate":[5,38,53],"non-invasively,":[6],"but":[7,26],"limits":[8],"patient":[9],"mobility":[10],"or":[11],"requires":[12,27],"regular":[13],"battery":[14],"replacement.":[15],"Respiratory":[16],"effort,":[17],"which":[18],"scavenge":[20],"mW,":[21],"may":[22],"power":[23,30,62,71,80],"the":[24],"sensor,":[25],"minimal":[28],"sensor":[29],"usage.":[31],"This":[32,67],"paper":[33],"demonstrates":[34],"feasibility":[35],"of":[36,45,78],"measurement":[39],"by":[40],"using":[41],"a":[42,60],"comparator":[43],"instead":[44],"ADC.":[46],"A":[47],"low-power":[48],"system-on-chip":[49],"implement":[51],"detection":[54],"and":[55,73],"wireless":[56],"data":[57],"transmission":[58,74],"with":[59],"total":[61,79],"consumption":[63],"under":[64,76],"82":[65],"\u00b5W.":[66],"approach":[68],"produces":[69],"significant":[70],"savings,":[72],"uses":[75],"30%":[77],"consumption.":[81]},"counts_by_year":[{"year":2014,"cited_by_count":1}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
