{"id":"https://openalex.org/W2036874702","doi":"https://doi.org/10.1109/embc.2012.6346548","title":"CHIC: Cylindrical Helix Imaging Coordinate Registration Fiducial for MRI-guided interventions","display_name":"CHIC: Cylindrical Helix Imaging Coordinate Registration Fiducial for MRI-guided interventions","publication_year":2012,"publication_date":"2012-08-01","ids":{"openalex":"https://openalex.org/W2036874702","doi":"https://doi.org/10.1109/embc.2012.6346548","mag":"2036874702","pmid":"https://pubmed.ncbi.nlm.nih.gov/23366509"},"language":"en","primary_location":{"id":"doi:10.1109/embc.2012.6346548","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2012.6346548","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5059708919","display_name":"Yunzhao Ma","orcid":null},"institutions":[{"id":"https://openalex.org/I107077323","display_name":"Worcester Polytechnic Institute","ror":"https://ror.org/05ejpqr48","country_code":"US","type":"education","lineage":["https://openalex.org/I107077323"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Yunzhao Ma","raw_affiliation_strings":["Automation and Interventional Medicine (AIM) Laboratory in the Department of Mechanical Engineering at Worcester Polytechnic Institute, Worcester, MA, USA","Automation and Interventional Medicine(AIM) Laboratory in the Department of Mechanical Engineering at Worcester Polytechnic Institute, MA, USA"],"affiliations":[{"raw_affiliation_string":"Automation and Interventional Medicine (AIM) Laboratory in the Department of Mechanical Engineering at Worcester Polytechnic Institute, Worcester, MA, USA","institution_ids":[]},{"raw_affiliation_string":"Automation and Interventional Medicine(AIM) Laboratory in the Department of Mechanical Engineering at Worcester Polytechnic Institute, MA, USA","institution_ids":["https://openalex.org/I107077323"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5009225855","display_name":"Ivo Dobrev","orcid":"https://orcid.org/0000-0002-6929-5711"},"institutions":[{"id":"https://openalex.org/I107077323","display_name":"Worcester Polytechnic Institute","ror":"https://ror.org/05ejpqr48","country_code":"US","type":"education","lineage":["https://openalex.org/I107077323"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"I. Dobrev","raw_affiliation_strings":["Automation and Interventional Medicine (AIM) Laboratory in the Department of Mechanical Engineering, Worcester Polytechnic Institute, Worcester, MA, USA","Automation and Interventional Medicine(AIM) Laboratory in the Department of Mechanical Engineering at Worcester Polytechnic Institute, MA, USA"],"affiliations":[{"raw_affiliation_string":"Automation and Interventional Medicine (AIM) Laboratory in the Department of Mechanical Engineering, Worcester Polytechnic Institute, Worcester, MA, USA","institution_ids":["https://openalex.org/I107077323"]},{"raw_affiliation_string":"Automation and Interventional Medicine(AIM) Laboratory in the Department of Mechanical Engineering at Worcester Polytechnic Institute, MA, USA","institution_ids":["https://openalex.org/I107077323"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5112273397","display_name":"Weijian Shang","orcid":null},"institutions":[{"id":"https://openalex.org/I107077323","display_name":"Worcester Polytechnic Institute","ror":"https://ror.org/05ejpqr48","country_code":"US","type":"education","lineage":["https://openalex.org/I107077323"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Weijian Shang","raw_affiliation_strings":["Automation and Interventional Medicine (AIM) Laboratory in the Department of Mechanical Engineering, Worcester Polytechnic Institute, Worcester, MA, USA","Automation and Interventional Medicine(AIM) Laboratory in the Department of Mechanical Engineering at Worcester Polytechnic Institute, MA, USA"],"affiliations":[{"raw_affiliation_string":"Automation and Interventional Medicine (AIM) Laboratory in the Department of Mechanical Engineering, Worcester Polytechnic Institute, Worcester, MA, USA","institution_ids":["https://openalex.org/I107077323"]},{"raw_affiliation_string":"Automation and Interventional Medicine(AIM) Laboratory in the Department of Mechanical Engineering at Worcester Polytechnic Institute, MA, USA","institution_ids":["https://openalex.org/I107077323"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5112135886","display_name":"Hao Su","orcid":null},"institutions":[{"id":"https://openalex.org/I107077323","display_name":"Worcester Polytechnic Institute","ror":"https://ror.org/05ejpqr48","country_code":"US","type":"education","lineage":["https://openalex.org/I107077323"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Hao Su","raw_affiliation_strings":["Automation and Interventional Medicine (AIM) Laboratory in the Department of Mechanical Engineering, Worcester Polytechnic Institute, Worcester, MA, USA","Automation and Interventional Medicine(AIM) Laboratory in the Department of Mechanical Engineering at Worcester Polytechnic Institute, MA, USA"],"affiliations":[{"raw_affiliation_string":"Automation and Interventional Medicine (AIM) Laboratory in the Department of Mechanical Engineering, Worcester Polytechnic Institute, Worcester, MA, USA","institution_ids":["https://openalex.org/I107077323"]},{"raw_affiliation_string":"Automation and Interventional Medicine(AIM) Laboratory in the Department of Mechanical Engineering at Worcester Polytechnic Institute, MA, USA","institution_ids":["https://openalex.org/I107077323"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5014599255","display_name":"Satyanarayana Reddy Janga","orcid":null},"institutions":[{"id":"https://openalex.org/I107077323","display_name":"Worcester Polytechnic Institute","ror":"https://ror.org/05ejpqr48","country_code":"US","type":"education","lineage":["https://openalex.org/I107077323"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"S. R. Janga","raw_affiliation_strings":["Automation and Interventional Medicine (AIM) Laboratory in the Department of Mechanical Engineering, Worcester Polytechnic Institute, Worcester, MA, USA","Automation and Interventional Medicine(AIM) Laboratory in the Department of Mechanical Engineering at Worcester Polytechnic Institute, MA, USA"],"affiliations":[{"raw_affiliation_string":"Automation and Interventional Medicine (AIM) Laboratory in the Department of Mechanical Engineering, Worcester Polytechnic Institute, Worcester, MA, USA","institution_ids":["https://openalex.org/I107077323"]},{"raw_affiliation_string":"Automation and Interventional Medicine(AIM) Laboratory in the Department of Mechanical Engineering at Worcester Polytechnic Institute, MA, USA","institution_ids":["https://openalex.org/I107077323"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5057001205","display_name":"Gregory S. Fischer","orcid":"https://orcid.org/0000-0001-6723-6614"},"institutions":[{"id":"https://openalex.org/I107077323","display_name":"Worcester Polytechnic Institute","ror":"https://ror.org/05ejpqr48","country_code":"US","type":"education","lineage":["https://openalex.org/I107077323"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Gregory S. Fischer","raw_affiliation_strings":["Automation and Interventional Medicine (AIM) Laboratory in the Department of Mechanical Engineering, Worcester Polytechnic Institute, Worcester, MA, USA","Automation and Interventional Medicine(AIM) Laboratory in the Department of Mechanical Engineering at Worcester Polytechnic Institute, MA, USA"],"affiliations":[{"raw_affiliation_string":"Automation and Interventional Medicine (AIM) Laboratory in the Department of Mechanical Engineering, Worcester Polytechnic Institute, Worcester, MA, USA","institution_ids":["https://openalex.org/I107077323"]},{"raw_affiliation_string":"Automation and Interventional Medicine(AIM) Laboratory in the Department of Mechanical Engineering at Worcester Polytechnic Institute, MA, USA","institution_ids":["https://openalex.org/I107077323"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":["https://openalex.org/A5059708919"],"corresponding_institution_ids":["https://openalex.org/I107077323"],"apc_list":null,"apc_paid":null,"fwci":0.2017,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.5567693,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"2012","issue":null,"first_page":"2808","last_page":"2812"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10868","display_name":"Soft Robotics and Applications","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10868","display_name":"Soft Robotics and Applications","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10916","display_name":"Surgical Simulation and Training","score":0.993399977684021,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10191","display_name":"Robotics and Sensor-Based Localization","score":0.9932000041007996,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fiducial-marker","display_name":"Fiducial marker","score":0.903843879699707},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6669203639030457},{"id":"https://openalex.org/keywords/computer-vision","display_name":"Computer vision","score":0.6429725289344788},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.6231144070625305},{"id":"https://openalex.org/keywords/image-registration","display_name":"Image registration","score":0.6067746877670288},{"id":"https://openalex.org/keywords/medical-imaging","display_name":"Medical imaging","score":0.5633889436721802},{"id":"https://openalex.org/keywords/frame","display_name":"Frame (networking)","score":0.518483579158783},{"id":"https://openalex.org/keywords/fluoroscopy","display_name":"Fluoroscopy","score":0.4907001256942749},{"id":"https://openalex.org/keywords/visualization","display_name":"Visualization","score":0.4848107397556305},{"id":"https://openalex.org/keywords/process","display_name":"Process (computing)","score":0.41634514927864075},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.21614497900009155},{"id":"https://openalex.org/keywords/radiology","display_name":"Radiology","score":0.2142656147480011},{"id":"https://openalex.org/keywords/image","display_name":"Image (mathematics)","score":0.18514719605445862}],"concepts":[{"id":"https://openalex.org/C173974348","wikidata":"https://www.wikidata.org/wiki/Q1469893","display_name":"Fiducial marker","level":2,"score":0.903843879699707},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6669203639030457},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.6429725289344788},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.6231144070625305},{"id":"https://openalex.org/C166704113","wikidata":"https://www.wikidata.org/wiki/Q861092","display_name":"Image registration","level":3,"score":0.6067746877670288},{"id":"https://openalex.org/C31601959","wikidata":"https://www.wikidata.org/wiki/Q931309","display_name":"Medical imaging","level":2,"score":0.5633889436721802},{"id":"https://openalex.org/C126042441","wikidata":"https://www.wikidata.org/wiki/Q1324888","display_name":"Frame (networking)","level":2,"score":0.518483579158783},{"id":"https://openalex.org/C2776805002","wikidata":"https://www.wikidata.org/wiki/Q614984","display_name":"Fluoroscopy","level":2,"score":0.4907001256942749},{"id":"https://openalex.org/C36464697","wikidata":"https://www.wikidata.org/wiki/Q451553","display_name":"Visualization","level":2,"score":0.4848107397556305},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.41634514927864075},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.21614497900009155},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.2142656147480011},{"id":"https://openalex.org/C115961682","wikidata":"https://www.wikidata.org/wiki/Q860623","display_name":"Image (mathematics)","level":2,"score":0.18514719605445862},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008279","descriptor_name":"Magnetic Resonance Imaging","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D008279","descriptor_name":"Magnetic Resonance Imaging","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D008279","descriptor_name":"Magnetic Resonance Imaging","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D014057","descriptor_name":"Tomography, X-Ray Computed","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014057","descriptor_name":"Tomography, X-Ray Computed","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014057","descriptor_name":"Tomography, X-Ray Computed","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D021621","descriptor_name":"Imaging, Three-Dimensional","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D021621","descriptor_name":"Imaging, Three-Dimensional","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D021621","descriptor_name":"Imaging, Three-Dimensional","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/embc.2012.6346548","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2012.6346548","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},{"id":"pmid:23366509","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/23366509","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/16","display_name":"Peace, Justice and strong institutions","score":0.8100000023841858}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W1491328080","https://openalex.org/W1539495916","https://openalex.org/W1969093871","https://openalex.org/W2014986029","https://openalex.org/W2056401399","https://openalex.org/W2108398132","https://openalex.org/W2126977300","https://openalex.org/W2132431375","https://openalex.org/W2138216764","https://openalex.org/W2161368485","https://openalex.org/W4245180467","https://openalex.org/W6632468409"],"related_works":["https://openalex.org/W2525537761","https://openalex.org/W2072325087","https://openalex.org/W402593573","https://openalex.org/W2905789513","https://openalex.org/W2972424784","https://openalex.org/W1486589819","https://openalex.org/W2471562626","https://openalex.org/W2461863667","https://openalex.org/W2295804706","https://openalex.org/W3168515805"],"abstract_inverted_index":{"Accurate":[0],"placement":[1],"of":[2,13,21,36,113,119,141,152,176,187],"tubular":[3,142],"shaped":[4,130],"surgical":[5,85,144,158,164],"tools":[6],"is":[7,31,76,122,132,174,182],"necessary":[8],"for":[9,33,68,135,184],"a":[10,25,92,148,167,177,185],"large":[11],"variety":[12,186],"image-guided":[14,188],"medical":[15,40],"interventions.":[16],"In":[17,73],"this":[18],"process,":[19],"localization":[20],"the":[22,29,84,90,108,120,138,157,171],"instrument,":[23,30],"or":[24,64,78],"robotic":[26],"assistant":[27],"manipulating":[28],"crucial":[32],"successful":[34],"registration":[35,47,179],"physical":[37],"space":[38],"to":[39,80,103,137,193],"image":[41],"space.":[42],"Various":[43],"fiducial":[44],"frames":[45,58],"and":[46,52,101,105,124,155,195,200,217],"methods":[48],"have":[49],"been":[50],"proposed":[51],"discussed":[53],"in":[54,62,110,204],"literature.":[55],"However,":[56],"these":[57],"are":[59],"typically":[60],"bulky":[61],"size":[63],"otherwise":[65],"not":[66],"appropriate":[67],"use":[69],"with":[70,83,126,209],"MR":[71],"imaging.":[72],"particular,":[74],"it":[75],"impossible":[77],"awkward":[79],"integrate":[81],"them":[82],"tools.":[86],"This":[87,128],"paper":[88,161],"presents":[89],"design":[91],"compact":[93],"Cylindrical":[94],"Helix":[95],"Imaging":[96],"Coordinate":[97],"Registration":[98],"Fiducial":[99],"(CHIC)":[100],"algorithm":[102],"precisely":[104],"robustly":[106],"localize":[107],"frame":[109,121,131,180],"6":[111],"degree":[112],"freedom":[114],"(DOF).":[115],"The":[116,160],"mathematical":[117],"model":[118],"developed":[123],"evaluated":[125,203],"simulation.":[127],"cylindrical":[129],"particularly":[133],"suitable":[134],"mounting":[136],"distal":[139],"end":[140],"shape":[143],"tools,":[145],"which":[146],"provides":[147],"direct":[149],"imaging":[150],"visualization":[151],"frame,":[153],"tool":[154],"possibly":[156],"sites.":[159],"uses":[162],"MRI-guided":[163],"procedure":[165],"as":[166],"focusing":[168],"application,":[169],"although":[170],"broader":[172],"aim":[173],"development":[175],"versatile":[178],"that":[181],"usable":[183],"procedures":[189],"ranging":[190],"from":[191],"ultrasound":[192],"fluoroscopy":[194],"computerized":[196],"tomography":[197],"(CT).":[198],"Accuracy":[199],"performance":[201],"were":[202],"three":[205],"cases:":[206],"simulated":[207],"images":[208],"artificial":[210],"noise,":[211],"arbitrarily":[212],"re-sliced":[213],"3D":[214],"MRI":[215,220],"volume,":[216],"real":[218],"3T":[219],"images.":[221]},"counts_by_year":[{"year":2013,"cited_by_count":1}],"updated_date":"2026-01-13T01:12:25.745995","created_date":"2025-10-10T00:00:00"}
