{"id":"https://openalex.org/W2026990147","doi":"https://doi.org/10.1109/embc.2012.6346253","title":"Statistical analysis of heart rate and heart rate variability monitoring through the use of smart phone cameras","display_name":"Statistical analysis of heart rate and heart rate variability monitoring through the use of smart phone cameras","publication_year":2012,"publication_date":"2012-08-01","ids":{"openalex":"https://openalex.org/W2026990147","doi":"https://doi.org/10.1109/embc.2012.6346253","mag":"2026990147","pmid":"https://pubmed.ncbi.nlm.nih.gov/23366214"},"language":"en","primary_location":{"id":"doi:10.1109/embc.2012.6346253","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2012.6346253","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5053980240","display_name":"Jeffrey Bolkhovsky","orcid":null},"institutions":[{"id":"https://openalex.org/I107077323","display_name":"Worcester Polytechnic Institute","ror":"https://ror.org/05ejpqr48","country_code":"US","type":"education","lineage":["https://openalex.org/I107077323"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Jeffrey B. Bolkhovsky","raw_affiliation_strings":["Biomedical Engineering Department, Worcester Polytechnic Institute, Worcester, MA 01609, USA. jbolkhovsky@wpi.edu","Biomedical Engineering Department, Worcester Polytechnic Institute, MA 01609 USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Biomedical Engineering Department, Worcester Polytechnic Institute, Worcester, MA 01609, USA. jbolkhovsky@wpi.edu","institution_ids":["https://openalex.org/I107077323"]},{"raw_affiliation_string":"Biomedical Engineering Department, Worcester Polytechnic Institute, MA 01609 USA","institution_ids":["https://openalex.org/I107077323"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5079054224","display_name":"Christopher G. Scully","orcid":"https://orcid.org/0000-0001-8244-0832"},"institutions":[{"id":"https://openalex.org/I107077323","display_name":"Worcester Polytechnic Institute","ror":"https://ror.org/05ejpqr48","country_code":"US","type":"education","lineage":["https://openalex.org/I107077323"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"C. G. Scully","raw_affiliation_strings":["Biomedical Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA","Biomedical Engineering Department, Worcester Polytechnic Institute, MA 01609 USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Biomedical Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA","institution_ids":["https://openalex.org/I107077323"]},{"raw_affiliation_string":"Biomedical Engineering Department, Worcester Polytechnic Institute, MA 01609 USA","institution_ids":["https://openalex.org/I107077323"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5032573836","display_name":"Ki H. Chon","orcid":"https://orcid.org/0000-0002-4422-4837"},"institutions":[{"id":"https://openalex.org/I107077323","display_name":"Worcester Polytechnic Institute","ror":"https://ror.org/05ejpqr48","country_code":"US","type":"education","lineage":["https://openalex.org/I107077323"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"K. H. Chon","raw_affiliation_strings":["Biomedical Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA","Biomedical Engineering Department, Worcester Polytechnic Institute, MA 01609 USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Biomedical Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA","institution_ids":["https://openalex.org/I107077323"]},{"raw_affiliation_string":"Biomedical Engineering Department, Worcester Polytechnic Institute, MA 01609 USA","institution_ids":["https://openalex.org/I107077323"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I107077323"],"apc_list":null,"apc_paid":null,"fwci":3.3137,"has_fulltext":false,"cited_by_count":61,"citation_normalized_percentile":{"value":0.91617308,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":90,"max":99},"biblio":{"volume":"2012","issue":null,"first_page":"1610","last_page":"1613"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9976999759674072,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/photoplethysmogram","display_name":"Photoplethysmogram","score":0.7129536867141724},{"id":"https://openalex.org/keywords/supine-position","display_name":"Supine position","score":0.6891424059867859},{"id":"https://openalex.org/keywords/heart-rate","display_name":"Heart rate","score":0.6817066669464111},{"id":"https://openalex.org/keywords/pulsatile-flow","display_name":"Pulsatile flow","score":0.6237589716911316},{"id":"https://openalex.org/keywords/signal","display_name":"SIGNAL (programming language)","score":0.5881995558738708},{"id":"https://openalex.org/keywords/heart-rate-variability","display_name":"Heart rate variability","score":0.5162320137023926},{"id":"https://openalex.org/keywords/standard-deviation","display_name":"Standard deviation","score":0.504485011100769},{"id":"https://openalex.org/keywords/heart-rate-monitor","display_name":"Heart rate monitor","score":0.4533282518386841},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4118586778640747},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.33734509348869324},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.3023931086063385},{"id":"https://openalex.org/keywords/cardiology","display_name":"Cardiology","score":0.26120299100875854},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.23111915588378906},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.2209630310535431},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.17709800601005554},{"id":"https://openalex.org/keywords/internal-medicine","display_name":"Internal medicine","score":0.17514324188232422},{"id":"https://openalex.org/keywords/blood-pressure","display_name":"Blood pressure","score":0.08096674084663391}],"concepts":[{"id":"https://openalex.org/C116390426","wikidata":"https://www.wikidata.org/wiki/Q7187885","display_name":"Photoplethysmogram","level":3,"score":0.7129536867141724},{"id":"https://openalex.org/C125567185","wikidata":"https://www.wikidata.org/wiki/Q3267428","display_name":"Supine position","level":2,"score":0.6891424059867859},{"id":"https://openalex.org/C2777953023","wikidata":"https://www.wikidata.org/wiki/Q1073121","display_name":"Heart rate","level":3,"score":0.6817066669464111},{"id":"https://openalex.org/C79191276","wikidata":"https://www.wikidata.org/wiki/Q7259620","display_name":"Pulsatile flow","level":2,"score":0.6237589716911316},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.5881995558738708},{"id":"https://openalex.org/C71635504","wikidata":"https://www.wikidata.org/wiki/Q933954","display_name":"Heart rate variability","level":4,"score":0.5162320137023926},{"id":"https://openalex.org/C22679943","wikidata":"https://www.wikidata.org/wiki/Q159375","display_name":"Standard deviation","level":2,"score":0.504485011100769},{"id":"https://openalex.org/C2775893642","wikidata":"https://www.wikidata.org/wiki/Q925303","display_name":"Heart rate monitor","level":4,"score":0.4533282518386841},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4118586778640747},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.33734509348869324},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.3023931086063385},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.26120299100875854},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.23111915588378906},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.2209630310535431},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.17709800601005554},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.17514324188232422},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.08096674084663391},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.0}],"mesh":[{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D005385","descriptor_name":"Fingers","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D005385","descriptor_name":"Fingers","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D005385","descriptor_name":"Fingers","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006339","descriptor_name":"Heart Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006339","descriptor_name":"Heart Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006339","descriptor_name":"Heart Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007091","descriptor_name":"Image Processing, Computer-Assisted","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D007091","descriptor_name":"Image Processing, Computer-Assisted","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D007091","descriptor_name":"Image Processing, Computer-Assisted","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D014741","descriptor_name":"Video Recording","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D014741","descriptor_name":"Video Recording","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D014741","descriptor_name":"Video Recording","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D016014","descriptor_name":"Linear Models","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D016014","descriptor_name":"Linear Models","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D016014","descriptor_name":"Linear Models","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D040421","descriptor_name":"Cell Phone","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D040421","descriptor_name":"Cell Phone","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D040421","descriptor_name":"Cell Phone","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true}],"locations_count":2,"locations":[{"id":"doi:10.1109/embc.2012.6346253","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2012.6346253","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},{"id":"pmid:23366214","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/23366214","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.6700000166893005,"display_name":"Good health and well-being","id":"https://metadata.un.org/sdg/3"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W1767708321","https://openalex.org/W1979316402","https://openalex.org/W2001140692","https://openalex.org/W2008821584","https://openalex.org/W2044936174","https://openalex.org/W2053924421","https://openalex.org/W2060642847","https://openalex.org/W2091314241","https://openalex.org/W2097379719","https://openalex.org/W2157911723","https://openalex.org/W2159348352","https://openalex.org/W6652753825"],"related_works":["https://openalex.org/W3196000489","https://openalex.org/W2092419518","https://openalex.org/W1489924780","https://openalex.org/W2135573418","https://openalex.org/W3016912561","https://openalex.org/W2621442247","https://openalex.org/W2907335586","https://openalex.org/W2610339238","https://openalex.org/W4280602869","https://openalex.org/W2806860136"],"abstract_inverted_index":{"Video":[0],"recordings":[1],"of":[2,74,129,137,145],"finger":[3],"tips":[4],"made":[5],"using":[6],"a":[7,11,24,40],"smartphone":[8],"camera":[9],"contain":[10],"pulsatile":[12,33,68],"component":[13],"caused":[14],"by":[15],"the":[16,32,72,81,88,109,138],"cardiac":[17],"pulse":[18],"equivalent":[19],"to":[20,38,70,131],"that":[21,150],"present":[22],"in":[23,87],"photoplethysmographic":[25],"signal.":[26,44],"By":[27],"performing":[28],"peak":[29],"detection":[30],"on":[31],"signal":[34,69],"it":[35],"is":[36],"possible":[37],"extract":[39],"continuous":[41],"heart":[42,53,75,111,114,120,152],"rate":[43,54,76,112,115,153],"We":[45],"performed":[46,86],"direct":[47],"comparisons":[48],"between":[49],"5-lead":[50],"electrocardiogram":[51],"based":[52,162],"variability":[55,77,116,154],"measurements":[56,78],"and":[57,64,90,101,108,113,141],"those":[58],"obtained":[59,79,158],"from":[60,80,159],"an":[61],"iPhone":[62,95],"4s":[63,96],"Motorola":[65],"Droid":[66,102],"derived":[67],"determine":[71],"accuracy":[73],"smart":[82,160],"phones.":[83],"Monitoring":[84],"was":[85],"supine":[89],"tilt":[91],"positions":[92],"for":[93],"independent":[94],"(2":[97],"min":[98,104],"recordings,":[99,105],"n=9)":[100],"(5":[103],"n=13)":[106],"experiments,":[107],"following":[110],"parameters":[117,155],"were":[118],"estimated:":[119],"rate,":[121],"low":[122,130],"frequency":[123,126,133],"power,":[124,127,134],"high":[125,132],"ratio":[128],"standard":[135],"deviation":[136],"RR":[139],"intervals,":[140],"root":[142],"mean":[143],"square":[144],"successive":[146],"RR-differences.":[147],"Results":[148],"demonstrate":[149],"accurate":[151],"can":[156],"be":[157],"phone":[161],"measurements.":[163]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":3},{"year":2023,"cited_by_count":5},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":4},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":9},{"year":2018,"cited_by_count":7},{"year":2017,"cited_by_count":6},{"year":2016,"cited_by_count":3},{"year":2015,"cited_by_count":9},{"year":2014,"cited_by_count":2},{"year":2013,"cited_by_count":4},{"year":2012,"cited_by_count":1}],"updated_date":"2026-06-26T08:34:08.712188","created_date":"2025-10-10T00:00:00"}
