{"id":"https://openalex.org/W1530448444","doi":"https://doi.org/10.1109/embc.2012.6346145","title":"Study on technology of high-frequency pulsed magnetic field strength measurement","display_name":"Study on technology of high-frequency pulsed magnetic field strength measurement","publication_year":2012,"publication_date":"2012-08-01","ids":{"openalex":"https://openalex.org/W1530448444","doi":"https://doi.org/10.1109/embc.2012.6346145","mag":"1530448444","pmid":"https://pubmed.ncbi.nlm.nih.gov/23366106"},"language":"en","primary_location":{"id":"doi:10.1109/embc.2012.6346145","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2012.6346145","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5107699527","display_name":"Yimei Chen","orcid":"https://orcid.org/0000-0002-9724-5981"},"institutions":[{"id":"https://openalex.org/I200296433","display_name":"Chinese Academy of Medical Sciences & Peking Union Medical College","ror":"https://ror.org/02drdmm93","country_code":"CN","type":"education","lineage":["https://openalex.org/I200296433"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Chen Yi-Mei","raw_affiliation_strings":["Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China","institution_ids":["https://openalex.org/I200296433"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Liu Zhi-Peng","orcid":null},"institutions":[{"id":"https://openalex.org/I200296433","display_name":"Chinese Academy of Medical Sciences & Peking Union Medical College","ror":"https://ror.org/02drdmm93","country_code":"CN","type":"education","lineage":["https://openalex.org/I200296433"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Liu Zhi-Peng","raw_affiliation_strings":["Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China","institution_ids":["https://openalex.org/I200296433"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101444532","display_name":"Tao Yin","orcid":"https://orcid.org/0000-0002-1747-6027"},"institutions":[{"id":"https://openalex.org/I200296433","display_name":"Chinese Academy of Medical Sciences & Peking Union Medical College","ror":"https://ror.org/02drdmm93","country_code":"CN","type":"education","lineage":["https://openalex.org/I200296433"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yin Tao","raw_affiliation_strings":["Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China","institution_ids":["https://openalex.org/I200296433"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I200296433"],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":"2012","issue":null,"first_page":"1173","last_page":"1176"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12692","display_name":"Magnetic Field Sensors Techniques","score":0.9915000200271606,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12692","display_name":"Magnetic Field Sensors Techniques","score":0.9915000200271606,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11993","display_name":"Atomic and Subatomic Physics Research","score":0.9672999978065491,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13885","display_name":"Geophysics and Sensor Technology","score":0.9419999718666077,"subfield":{"id":"https://openalex.org/subfields/2212","display_name":"Ocean Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/magnetic-field","display_name":"Magnetic field","score":0.7658964395523071},{"id":"https://openalex.org/keywords/field-strength","display_name":"Field strength","score":0.6570039391517639},{"id":"https://openalex.org/keywords/electromagnetic-coil","display_name":"Electromagnetic coil","score":0.6424164772033691},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.6222403049468994},{"id":"https://openalex.org/keywords/electromotive-force","display_name":"Electromotive force","score":0.5940637588500977},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.5238004922866821},{"id":"https://openalex.org/keywords/field","display_name":"Field (mathematics)","score":0.4743156135082245},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.46541905403137207},{"id":"https://openalex.org/keywords/measure","display_name":"Measure (data warehouse)","score":0.4202615022659302},{"id":"https://openalex.org/keywords/search-coil","display_name":"Search coil","score":0.42011603713035583},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.4167558550834656},{"id":"https://openalex.org/keywords/magnetic-reactance","display_name":"Magnetic reactance","score":0.4160798192024231},{"id":"https://openalex.org/keywords/magnetic-flux","display_name":"Magnetic flux","score":0.39979586005210876},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.389125257730484},{"id":"https://openalex.org/keywords/demagnetizing-field","display_name":"Demagnetizing field","score":0.3491542637348175},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.26776647567749023},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.24190661311149597},{"id":"https://openalex.org/keywords/magnetization","display_name":"Magnetization","score":0.1393883228302002},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.11596855521202087}],"concepts":[{"id":"https://openalex.org/C115260700","wikidata":"https://www.wikidata.org/wiki/Q11408","display_name":"Magnetic field","level":2,"score":0.7658964395523071},{"id":"https://openalex.org/C187309904","wikidata":"https://www.wikidata.org/wiki/Q1365197","display_name":"Field strength","level":3,"score":0.6570039391517639},{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.6424164772033691},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.6222403049468994},{"id":"https://openalex.org/C127535462","wikidata":"https://www.wikidata.org/wiki/Q185329","display_name":"Electromotive force","level":2,"score":0.5940637588500977},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.5238004922866821},{"id":"https://openalex.org/C9652623","wikidata":"https://www.wikidata.org/wiki/Q190109","display_name":"Field (mathematics)","level":2,"score":0.4743156135082245},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.46541905403137207},{"id":"https://openalex.org/C2780009758","wikidata":"https://www.wikidata.org/wiki/Q6804172","display_name":"Measure (data warehouse)","level":2,"score":0.4202615022659302},{"id":"https://openalex.org/C63236149","wikidata":"https://www.wikidata.org/wiki/Q635465","display_name":"Search coil","level":4,"score":0.42011603713035583},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.4167558550834656},{"id":"https://openalex.org/C179044611","wikidata":"https://www.wikidata.org/wiki/Q5625391","display_name":"Magnetic reactance","level":5,"score":0.4160798192024231},{"id":"https://openalex.org/C157479481","wikidata":"https://www.wikidata.org/wiki/Q177831","display_name":"Magnetic flux","level":3,"score":0.39979586005210876},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.389125257730484},{"id":"https://openalex.org/C60434167","wikidata":"https://www.wikidata.org/wiki/Q5255001","display_name":"Demagnetizing field","level":4,"score":0.3491542637348175},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.26776647567749023},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.24190661311149597},{"id":"https://openalex.org/C32546565","wikidata":"https://www.wikidata.org/wiki/Q856711","display_name":"Magnetization","level":3,"score":0.1393883228302002},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.11596855521202087},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C202444582","wikidata":"https://www.wikidata.org/wiki/Q837863","display_name":"Pure mathematics","level":1,"score":0.0},{"id":"https://openalex.org/C77088390","wikidata":"https://www.wikidata.org/wiki/Q8513","display_name":"Database","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D008280","descriptor_name":"Magnetics","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D008280","descriptor_name":"Magnetics","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D008280","descriptor_name":"Magnetics","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D008962","descriptor_name":"Models, Theoretical","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D008962","descriptor_name":"Models, Theoretical","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D008962","descriptor_name":"Models, Theoretical","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D059346","descriptor_name":"Magnets","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D059346","descriptor_name":"Magnets","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D059346","descriptor_name":"Magnets","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D060526","descriptor_name":"Magnetic Fields","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D060526","descriptor_name":"Magnetic Fields","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D060526","descriptor_name":"Magnetic Fields","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true}],"locations_count":2,"locations":[{"id":"doi:10.1109/embc.2012.6346145","is_oa":false,"landing_page_url":"https://doi.org/10.1109/embc.2012.6346145","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},{"id":"pmid:23366106","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/23366106","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W2157056671","https://openalex.org/W2359254656","https://openalex.org/W2370183378","https://openalex.org/W2371046953","https://openalex.org/W2379927190","https://openalex.org/W2385950150","https://openalex.org/W2389028552","https://openalex.org/W2390982091","https://openalex.org/W4233736521","https://openalex.org/W4248511430"],"related_works":["https://openalex.org/W2378249520","https://openalex.org/W2114675744","https://openalex.org/W1519493069","https://openalex.org/W2386695368","https://openalex.org/W2363532213","https://openalex.org/W2006908194","https://openalex.org/W2093238250","https://openalex.org/W2025920744","https://openalex.org/W1968337655","https://openalex.org/W2959376929"],"abstract_inverted_index":{"High-frequency":[0],"transient":[1],"weak":[2,33],"magnetic":[3,65,76,102],"field":[4,13,66,77,103],"is":[5],"always":[6],"involved":[7],"in":[8,111],"researches":[9],"about":[10,165],"biomedical":[11],"engineering":[12],"while":[14],"common":[15],"magnetic-field":[16,35,136,141],"sensors":[17],"cannot":[18],"work":[19],"properly":[20],"at":[21,147,155],"frequencies":[22],"as":[23,25],"high":[24],"MHz.":[26],"To":[27],"measure":[28],"the":[29,75,81,90,93,98,100],"value":[30],"of":[31,55,97,135,138],"MHz-level":[32],"pulsed":[34,47,64],"strength":[36,104,137,153],"accurately,":[37],"this":[38,50],"paper":[39],"designs":[40],"a":[41,52,86,139,161],"measurement":[42,122,134],"and":[43,61,80,123,131,152],"calibration":[44],"method":[45],"for":[46,121],"magnetic-field.":[48],"In":[49],"paper,":[51],"device":[53],"made":[54],"Nonferromagnetic":[56],"material":[57],"was":[58,105],"independently":[59],"designed":[60],"applied":[62],"to":[63,89,114],"measurement.":[67],"It":[68],"held":[69],"an":[70],"accurately":[71],"relative":[72,163],"position":[73],"between":[74],"generating":[78],"coil":[79],"detecting":[82],"coil.":[83],"By":[84],"applying":[85],"sinusoidal":[87],"pulse":[88],"generator,":[91],"collecting":[92],"induced":[94],"electromotive":[95],"force":[96],"detector,":[99],"final":[101],"worked":[106],"out":[107,120,160],"through":[108],"algorithms":[109],"written":[110],"Matlab":[112],"according":[113],"Faraday's":[115],"Law.":[116],"Experiments":[117,125],"were":[118],"carried":[119,159],"calibration.":[124],"showed":[126],"that,":[127],"under":[128],"good":[129],"stability":[130],"consistency,":[132],"accurate":[133],"sinepulse":[140],"can":[142],"be":[143],"achieved,":[144],"with":[145],"frequency":[146],"0.5,":[148],"1,":[149],"1.5":[150],"MHz":[151],"level":[154],"micro-Tesla.":[156],"Calibration":[157],"results":[158],"measuring":[162],"error":[164],"2.5%.":[166]},"counts_by_year":[{"year":2022,"cited_by_count":2},{"year":2015,"cited_by_count":1}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
