{"id":"https://openalex.org/W2086362812","doi":"https://doi.org/10.1109/ecc.2014.6862330","title":"Distributed building temperature control with power constraints","display_name":"Distributed building temperature control with power constraints","publication_year":2014,"publication_date":"2014-06-01","ids":{"openalex":"https://openalex.org/W2086362812","doi":"https://doi.org/10.1109/ecc.2014.6862330","mag":"2086362812"},"language":"en","primary_location":{"id":"doi:10.1109/ecc.2014.6862330","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ecc.2014.6862330","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 European Control Conference (ECC)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5078856468","display_name":"Germ\u00e1n Obando","orcid":"https://orcid.org/0000-0003-4271-4944"},"institutions":[{"id":"https://openalex.org/I3019848993","display_name":"Mines Saint-\u00c9tienne","ror":"https://ror.org/05a1dws80","country_code":"FR","type":"education","lineage":["https://openalex.org/I203339264","https://openalex.org/I205703379","https://openalex.org/I3019848993"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"German Obando","raw_affiliation_strings":["Departamento de Ingenier\u00eda El\u00e9ctrica y Electr\u00f3nica, Ecole des Mines de Nantes, and IRCCyNG. Obando is supported in part by Colciencias-Colfuturo, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Departamento de Ingenier\u00eda El\u00e9ctrica y Electr\u00f3nica, Ecole des Mines de Nantes, and IRCCyNG. Obando is supported in part by Colciencias-Colfuturo, France","institution_ids":["https://openalex.org/I3019848993"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5010955102","display_name":"Nicanor Quijano","orcid":"https://orcid.org/0000-0002-8688-3195"},"institutions":[{"id":"https://openalex.org/I162096671","display_name":"Universidad de Los Andes","ror":"https://ror.org/02mhbdp94","country_code":"CO","type":"education","lineage":["https://openalex.org/I162096671"]}],"countries":["CO"],"is_corresponding":false,"raw_author_name":"Nicanor Quijano","raw_affiliation_strings":["Departamento de Ingenier\u00eda El\u00e9ctrica y Electr\u00f3nica, Universidad de los Andes, Colombia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Departamento de Ingenier\u00eda El\u00e9ctrica y Electr\u00f3nica, Universidad de los Andes, Colombia","institution_ids":["https://openalex.org/I162096671"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5089716427","display_name":"Naly Rakoto\u2013Ravalontsalama","orcid":"https://orcid.org/0000-0002-5798-0359"},"institutions":[{"id":"https://openalex.org/I70768539","display_name":"\u00c9cole Nationale Sup\u00e9rieure des Mines de Paris","ror":"https://ror.org/04y8cs423","country_code":"FR","type":"education","lineage":["https://openalex.org/I190752583","https://openalex.org/I2746051580","https://openalex.org/I70768539"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Naly Rakoto-Ravalontsalama","raw_affiliation_strings":["Ecole des Mines de Nantes, and IRCCyN, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Ecole des Mines de Nantes, and IRCCyN, France","institution_ids":["https://openalex.org/I70768539"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.4472,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.89636206,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":97},"biblio":{"volume":"1","issue":null,"first_page":"2857","last_page":"2862"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.995199978351593,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.995199978351593,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9922999739646912,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9884999990463257,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.9617226123809814},{"id":"https://openalex.org/keywords/inefficiency","display_name":"Inefficiency","score":0.6360787153244019},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.6178004741668701},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5474749207496643},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.5134623646736145},{"id":"https://openalex.org/keywords/passivity","display_name":"Passivity","score":0.4915083348751068},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4614051878452301},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.448862224817276},{"id":"https://openalex.org/keywords/thermostat","display_name":"Thermostat","score":0.42992645502090454},{"id":"https://openalex.org/keywords/cooling-load","display_name":"Cooling load","score":0.42956164479255676},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.4127700924873352},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.3499763011932373},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.3464227318763733},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.29174113273620605},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.15721887350082397},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.11917752027511597}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.9617226123809814},{"id":"https://openalex.org/C2778869765","wikidata":"https://www.wikidata.org/wiki/Q6028363","display_name":"Inefficiency","level":2,"score":0.6360787153244019},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.6178004741668701},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5474749207496643},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.5134623646736145},{"id":"https://openalex.org/C2778809601","wikidata":"https://www.wikidata.org/wiki/Q1045736","display_name":"Passivity","level":2,"score":0.4915083348751068},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4614051878452301},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.448862224817276},{"id":"https://openalex.org/C187819001","wikidata":"https://www.wikidata.org/wiki/Q187665","display_name":"Thermostat","level":2,"score":0.42992645502090454},{"id":"https://openalex.org/C2781099182","wikidata":"https://www.wikidata.org/wiki/Q24963825","display_name":"Cooling load","level":3,"score":0.42956164479255676},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.4127700924873352},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.3499763011932373},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3464227318763733},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.29174113273620605},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.15721887350082397},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.11917752027511597},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C175444787","wikidata":"https://www.wikidata.org/wiki/Q39072","display_name":"Microeconomics","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/ecc.2014.6862330","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ecc.2014.6862330","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 European Control Conference (ECC)","raw_type":"proceedings-article"},{"id":"pmh:oai:HAL:hal-01206884v1","is_oa":false,"landing_page_url":"https://imt-atlantique.hal.science/hal-01206884","pdf_url":null,"source":{"id":"https://openalex.org/S4306402512","display_name":"HAL (Le Centre pour la Communication Scientifique Directe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1294671590","host_organization_name":"Centre National de la Recherche Scientifique","host_organization_lineage":["https://openalex.org/I1294671590"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"ECC 2014: EUROPEAN CONTROL CONFERENCE, Jun 2014, Strasbourg, France. pp.2857-2862, &#x27E8;10.1109/ECC.2014.6862330&#x27E9;","raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.8799999952316284,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":17,"referenced_works":["https://openalex.org/W146390624","https://openalex.org/W1542401826","https://openalex.org/W1972809627","https://openalex.org/W2000244143","https://openalex.org/W2017330181","https://openalex.org/W2055554147","https://openalex.org/W2085763351","https://openalex.org/W2092792488","https://openalex.org/W2114085163","https://openalex.org/W2164132178","https://openalex.org/W2172498959","https://openalex.org/W2726938673","https://openalex.org/W4205648119","https://openalex.org/W4238591275","https://openalex.org/W4250589301","https://openalex.org/W6605955637","https://openalex.org/W6740552509"],"related_works":["https://openalex.org/W2066400031","https://openalex.org/W2603855141","https://openalex.org/W2023346859","https://openalex.org/W2150984846","https://openalex.org/W2772340292","https://openalex.org/W2894949236","https://openalex.org/W2340839802","https://openalex.org/W2954483851","https://openalex.org/W3000938991","https://openalex.org/W267418541"],"abstract_inverted_index":{"Generally,":[0],"heating,":[1],"cooling":[2],"and":[3,15,49,83,104],"air":[4],"conditioning":[5],"(HVAC)":[6],"systems":[7],"are":[8,106],"designed":[9],"to":[10,108],"handle":[11],"worst":[12],"case":[13],"loads,":[14],"this":[16],"over-design":[17],"of":[18,23,45,67,79,98,112],"HVAC":[19,33],"equipment":[20],"is":[21,35],"one":[22],"the":[24,32,43,46,50,65,68,87,96,110],"main":[25],"reasons":[26],"for":[27],"building":[28],"energy":[29],"inefficiency.":[30],"When":[31],"system":[34],"not":[36],"over-designed,":[37],"there":[38],"exists":[39],"a":[40,60],"trade-off":[41],"between":[42],"comfort":[44,66],"building's":[47,69],"occupants":[48,70],"available":[51],"heating/cooling":[52],"power":[53,73],"at":[54],"critical":[55],"load":[56],"hours.":[57],"We":[58,75],"propose":[59],"distributed":[61],"approach":[62],"that":[63,86],"maximizes":[64],"under":[71],"several":[72],"constraints.":[74],"prove":[76],"by":[77],"means":[78],"graph":[80],"theoretical":[81],"tools":[82],"passivity":[84],"analysis,":[85],"proposed":[88],"controller":[89],"asymptotically":[90],"reaches":[91],"an":[92],"optimal":[93],"equilibrium":[94],"without":[95],"need":[97],"full":[99],"information.":[100],"Finally,":[101],"some":[102],"simulations":[103],"comparisons":[105],"presented":[107],"illustrate":[109],"performance":[111],"our":[113],"method.":[114]},"counts_by_year":[{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":3},{"year":2015,"cited_by_count":2}],"updated_date":"2026-08-02T14:50:37.381335","created_date":"2025-10-10T00:00:00"}
