{"id":"https://openalex.org/W2126226249","doi":"https://doi.org/10.1109/ecc.2014.6862318","title":"A time-delay approach for modeling and control of mist in a poiseuille flow","display_name":"A time-delay approach for modeling and control of mist in a poiseuille flow","publication_year":2014,"publication_date":"2014-06-01","ids":{"openalex":"https://openalex.org/W2126226249","doi":"https://doi.org/10.1109/ecc.2014.6862318","mag":"2126226249"},"language":"en","primary_location":{"id":"doi:10.1109/ecc.2014.6862318","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ecc.2014.6862318","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 European Control Conference (ECC)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5005869596","display_name":"Miguel \u00c1ngel Hern\u00e1ndez P\u00e9rez","orcid":"https://orcid.org/0000-0001-9818-1898"},"institutions":[{"id":"https://openalex.org/I177483745","display_name":"Universit\u00e9 Joseph Fourier","ror":"https://ror.org/02aj0kh94","country_code":"FR","type":"education","lineage":["https://openalex.org/I177483745"]},{"id":"https://openalex.org/I4210124956","display_name":"GIPSA-Lab","ror":"https://ror.org/02wrme198","country_code":"FR","type":"facility","lineage":["https://openalex.org/I106785703","https://openalex.org/I1294671590","https://openalex.org/I4210124956","https://openalex.org/I899635006","https://openalex.org/I899635006"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Miguel A. Hernandez Perez","raw_affiliation_strings":["Grenoble Images Parole Signal Automatique (GIPSA-Lab), Universite Joseph Fourier, Grenoble, France","Grenoble Images Parole Signal Autom. (GIPSA-Lab.), Univ. Joseph Fourier, St. Martin d'He\u0300res, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Grenoble Images Parole Signal Automatique (GIPSA-Lab), Universite Joseph Fourier, Grenoble, France","institution_ids":["https://openalex.org/I177483745","https://openalex.org/I4210124956"]},{"raw_affiliation_string":"Grenoble Images Parole Signal Autom. (GIPSA-Lab.), Univ. Joseph Fourier, St. Martin d'He\u0300res, France","institution_ids":["https://openalex.org/I4210124956"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5029011489","display_name":"Emmanuel Witrant","orcid":"https://orcid.org/0000-0002-2026-8915"},"institutions":[{"id":"https://openalex.org/I177483745","display_name":"Universit\u00e9 Joseph Fourier","ror":"https://ror.org/02aj0kh94","country_code":"FR","type":"education","lineage":["https://openalex.org/I177483745"]},{"id":"https://openalex.org/I4210124956","display_name":"GIPSA-Lab","ror":"https://ror.org/02wrme198","country_code":"FR","type":"facility","lineage":["https://openalex.org/I106785703","https://openalex.org/I1294671590","https://openalex.org/I4210124956","https://openalex.org/I899635006","https://openalex.org/I899635006"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Emmanuel Witrant","raw_affiliation_strings":["Grenoble Images Parole Signal Automatique (GIPSA-Lab), Universite Joseph Fourier, Grenoble, France","Grenoble Images Parole Signal Autom. (GIPSA-Lab.), Univ. Joseph Fourier, St. Martin d'He\u0300res, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Grenoble Images Parole Signal Automatique (GIPSA-Lab), Universite Joseph Fourier, Grenoble, France","institution_ids":["https://openalex.org/I177483745","https://openalex.org/I4210124956"]},{"raw_affiliation_string":"Grenoble Images Parole Signal Autom. (GIPSA-Lab.), Univ. Joseph Fourier, St. Martin d'He\u0300res, France","institution_ids":["https://openalex.org/I4210124956"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5106941545","display_name":"Olivier Sename","orcid":"https://orcid.org/0000-0001-9595-9000"},"institutions":[{"id":"https://openalex.org/I177483745","display_name":"Universit\u00e9 Joseph Fourier","ror":"https://ror.org/02aj0kh94","country_code":"FR","type":"education","lineage":["https://openalex.org/I177483745"]},{"id":"https://openalex.org/I4210124956","display_name":"GIPSA-Lab","ror":"https://ror.org/02wrme198","country_code":"FR","type":"facility","lineage":["https://openalex.org/I106785703","https://openalex.org/I1294671590","https://openalex.org/I4210124956","https://openalex.org/I899635006","https://openalex.org/I899635006"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Olivier Sename","raw_affiliation_strings":["Grenoble Images Parole Signal Automatique (GIPSA-Lab), Universite Joseph Fourier, Grenoble, France","Grenoble Images Parole Signal Autom. (GIPSA-Lab.), Univ. Joseph Fourier, St. Martin d'He\u0300res, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Grenoble Images Parole Signal Automatique (GIPSA-Lab), Universite Joseph Fourier, Grenoble, France","institution_ids":["https://openalex.org/I177483745","https://openalex.org/I4210124956"]},{"raw_affiliation_string":"Grenoble Images Parole Signal Autom. (GIPSA-Lab.), Univ. Joseph Fourier, St. Martin d'He\u0300res, France","institution_ids":["https://openalex.org/I4210124956"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.9319,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.71374797,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":"40","issue":null,"first_page":"1115","last_page":"1120"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11081","display_name":"Advanced Control Systems Design","score":0.9972000122070312,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11236","display_name":"Control Systems and Identification","score":0.9916999936103821,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.6984331011772156},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.5838886499404907},{"id":"https://openalex.org/keywords/hagen\u2013poiseuille-equation","display_name":"Hagen\u2013Poiseuille equation","score":0.5026357173919678},{"id":"https://openalex.org/keywords/advection","display_name":"Advection","score":0.5023486614227295},{"id":"https://openalex.org/keywords/mist","display_name":"Mist","score":0.47402340173721313},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.46453243494033813},{"id":"https://openalex.org/keywords/flow","display_name":"Flow (mathematics)","score":0.4600830376148224},{"id":"https://openalex.org/keywords/test-bench","display_name":"Test bench","score":0.44441312551498413},{"id":"https://openalex.org/keywords/work","display_name":"Work (physics)","score":0.4317636489868164},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.33715325593948364},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.33009761571884155},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2505010962486267},{"id":"https://openalex.org/keywords/mechanics","display_name":"Mechanics","score":0.1500425934791565},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.08856630325317383},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.0868687629699707},{"id":"https://openalex.org/keywords/meteorology","display_name":"Meteorology","score":0.07461664080619812}],"concepts":[{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6984331011772156},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.5838886499404907},{"id":"https://openalex.org/C175336444","wikidata":"https://www.wikidata.org/wiki/Q869854","display_name":"Hagen\u2013Poiseuille equation","level":3,"score":0.5026357173919678},{"id":"https://openalex.org/C5072599","wikidata":"https://www.wikidata.org/wiki/Q379788","display_name":"Advection","level":2,"score":0.5023486614227295},{"id":"https://openalex.org/C6831451","wikidata":"https://www.wikidata.org/wiki/Q192196","display_name":"Mist","level":2,"score":0.47402340173721313},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.46453243494033813},{"id":"https://openalex.org/C38349280","wikidata":"https://www.wikidata.org/wiki/Q1434290","display_name":"Flow (mathematics)","level":2,"score":0.4600830376148224},{"id":"https://openalex.org/C2776266606","wikidata":"https://www.wikidata.org/wiki/Q476482","display_name":"Test bench","level":2,"score":0.44441312551498413},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.4317636489868164},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.33715325593948364},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.33009761571884155},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2505010962486267},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.1500425934791565},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.08856630325317383},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.0868687629699707},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.07461664080619812},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ecc.2014.6862318","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ecc.2014.6862318","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 European Control Conference (ECC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Climate action","score":0.5,"id":"https://metadata.un.org/sdg/13"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":22,"referenced_works":["https://openalex.org/W910658697","https://openalex.org/W1498203006","https://openalex.org/W1668775534","https://openalex.org/W1973979635","https://openalex.org/W1986615027","https://openalex.org/W1997398744","https://openalex.org/W2007784570","https://openalex.org/W2030338049","https://openalex.org/W2034631507","https://openalex.org/W2053599456","https://openalex.org/W2062413722","https://openalex.org/W2107154793","https://openalex.org/W2113433055","https://openalex.org/W2113713500","https://openalex.org/W2115851150","https://openalex.org/W2118420115","https://openalex.org/W2149162789","https://openalex.org/W2162853993","https://openalex.org/W2171396833","https://openalex.org/W2625248524","https://openalex.org/W6624211995","https://openalex.org/W6637024267"],"related_works":["https://openalex.org/W2358279768","https://openalex.org/W2383291219","https://openalex.org/W2349572614","https://openalex.org/W2367041282","https://openalex.org/W2023900323","https://openalex.org/W2472801082","https://openalex.org/W2048390140","https://openalex.org/W2391634122","https://openalex.org/W2350923989","https://openalex.org/W2382936403"],"abstract_inverted_index":{"Moisture":[0],"control":[1,56],"in":[2,11,16,68],"advective":[3],"flow":[4],"systems":[5],"with":[6,74,88],"time":[7],"delay":[8],"is":[9,25,58],"studied":[10],"this":[12],"work":[13],"and":[14,34,46,66,72,80,93,98],"assessed":[15],"a":[17,31,75,89],"process-control":[18],"system":[19],"(test":[20],"bench).":[21],"A":[22,53],"control-oriented":[23],"model":[24,44],"proposed":[26],"by":[27],"considering":[28],"advection":[29],"as":[30,40],"transport":[32],"time-delay":[33],"the":[35],"sensitivity":[36],"to":[37,61],"operating":[38],"conditions":[39],"structured":[41],"uncertainties.":[42],"The":[43,84],"parameters":[45],"variations":[47],"are":[48,86],"identified":[49],"from":[50],"experimental":[51,99],"results.":[52,100],"guaranteed":[54],"cost":[55],"strategy":[57,92],"then":[59],"used":[60],"handle":[62],"both":[63,96],"time-varying":[64],"delays":[65],"uncertainties":[67],"an":[69,81],"optimal":[70],"design,":[71],"improved":[73],"linear":[76],"change":[77],"of":[78],"variables":[79],"integral":[82],"action.":[83],"results":[85],"compared":[87],"traditional":[90],"PI":[91],"evaluated":[94],"on":[95],"simulation":[97]},"counts_by_year":[{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":1}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
