{"id":"https://openalex.org/W2951109280","doi":"https://doi.org/10.1109/ecai.2018.8679066","title":"Computer-aided appliances to underground machines maintenance \u2013 Selected issues","display_name":"Computer-aided appliances to underground machines maintenance \u2013 Selected issues","publication_year":2018,"publication_date":"2018-06-01","ids":{"openalex":"https://openalex.org/W2951109280","doi":"https://doi.org/10.1109/ecai.2018.8679066","mag":"2951109280"},"language":"en","primary_location":{"id":"doi:10.1109/ecai.2018.8679066","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ecai.2018.8679066","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 10th International Conference on Electronics, Computers and Artificial Intelligence (ECAI)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5051852979","display_name":"Mark Jasinski","orcid":null},"institutions":[{"id":"https://openalex.org/I11923345","display_name":"Wroc\u0142aw University of Science and Technology","ror":"https://ror.org/008fyn775","country_code":"PL","type":"education","lineage":["https://openalex.org/I11923345"]},{"id":"https://openalex.org/I46597724","display_name":"Pozna\u0144 University of Technology","ror":"https://ror.org/00p7p3302","country_code":"PL","type":"education","lineage":["https://openalex.org/I46597724"]},{"id":"https://openalex.org/I686019","display_name":"AGH University of Krakow","ror":"https://ror.org/00bas1c41","country_code":"PL","type":"education","lineage":["https://openalex.org/I686019"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Mark Jasinski","raw_affiliation_strings":["Faculty of Electrical Engineering, Wroclaw University of Science and Technology, Wroclaw, Poland","Faculty of Engineering Management, Poznan University of Technology, Poznan, Poland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Faculty of Electrical Engineering, Wroclaw University of Science and Technology, Wroclaw, Poland","institution_ids":["https://openalex.org/I11923345","https://openalex.org/I686019"]},{"raw_affiliation_string":"Faculty of Engineering Management, Poznan University of Technology, Poznan, Poland","institution_ids":["https://openalex.org/I46597724"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5066964559","display_name":"El\u017cbieta Jasi\u0144ska","orcid":"https://orcid.org/0000-0003-2433-3873"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Elzbieta Jasinska","raw_affiliation_strings":["Jan Wyzykowski University Branch Department in Lubin, Polkowice, Poland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Jan Wyzykowski University Branch Department in Lubin, Polkowice, Poland","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5052139542","display_name":"Micha\u0142 Jasi\u0144ski","orcid":"https://orcid.org/0000-0002-0983-2562"},"institutions":[{"id":"https://openalex.org/I11923345","display_name":"Wroc\u0142aw University of Science and Technology","ror":"https://ror.org/008fyn775","country_code":"PL","type":"education","lineage":["https://openalex.org/I11923345"]},{"id":"https://openalex.org/I46597724","display_name":"Pozna\u0144 University of Technology","ror":"https://ror.org/00p7p3302","country_code":"PL","type":"education","lineage":["https://openalex.org/I46597724"]},{"id":"https://openalex.org/I686019","display_name":"AGH University of Krakow","ror":"https://ror.org/00bas1c41","country_code":"PL","type":"education","lineage":["https://openalex.org/I686019"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Michal Jasinski","raw_affiliation_strings":["Faculty of Electrical Engineering, Wroclaw University of Science and Technology, Wroclaw, Poland","Faculty of Engineering Management, Poznan University of Technology, Poznan, Poland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Faculty of Electrical Engineering, Wroclaw University of Science and Technology, Wroclaw, Poland","institution_ids":["https://openalex.org/I11923345","https://openalex.org/I686019"]},{"raw_affiliation_string":"Faculty of Engineering Management, Poznan University of Technology, Poznan, Poland","institution_ids":["https://openalex.org/I46597724"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5027516471","display_name":"\u0141ukasz Jasi\u0144ski","orcid":"https://orcid.org/0000-0002-7484-9424"},"institutions":[{"id":"https://openalex.org/I11923345","display_name":"Wroc\u0142aw University of Science and Technology","ror":"https://ror.org/008fyn775","country_code":"PL","type":"education","lineage":["https://openalex.org/I11923345"]},{"id":"https://openalex.org/I686019","display_name":"AGH University of Krakow","ror":"https://ror.org/00bas1c41","country_code":"PL","type":"education","lineage":["https://openalex.org/I686019"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Lukasz Jasinski","raw_affiliation_strings":["Faculty of Electrical Engineering, Wroclaw University of Science and Technology, Wroclaw, Poland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Faculty of Electrical Engineering, Wroclaw University of Science and Technology, Wroclaw, Poland","institution_ids":["https://openalex.org/I11923345","https://openalex.org/I686019"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.1709,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.5476149,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13341","display_name":"Belt Conveyor Systems Engineering","score":0.9973999857902527,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T13341","display_name":"Belt Conveyor Systems Engineering","score":0.9973999857902527,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13451","display_name":"Mechanical Engineering Research and Applications","score":0.9954000115394592,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13857","display_name":"Mining and Industrial Processes","score":0.9937999844551086,"subfield":{"id":"https://openalex.org/subfields/1106","display_name":"Food Science"},"field":{"id":"https://openalex.org/fields/11","display_name":"Agricultural and Biological Sciences"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/mean-time-between-failures","display_name":"Mean time between failures","score":0.9734035134315491},{"id":"https://openalex.org/keywords/truck","display_name":"Truck","score":0.7706791162490845},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.6211475729942322},{"id":"https://openalex.org/keywords/maintenance-engineering","display_name":"Maintenance engineering","score":0.5576514601707458},{"id":"https://openalex.org/keywords/hydraulic-machinery","display_name":"Hydraulic machinery","score":0.5256836414337158},{"id":"https://openalex.org/keywords/component","display_name":"Component (thermodynamics)","score":0.5152673721313477},{"id":"https://openalex.org/keywords/preventive-maintenance","display_name":"Preventive maintenance","score":0.49304887652397156},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.4776771664619446},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4541376233100891},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.4282014071941376},{"id":"https://openalex.org/keywords/copper-mine","display_name":"Copper mine","score":0.42624717950820923},{"id":"https://openalex.org/keywords/failure-rate","display_name":"Failure rate","score":0.20599365234375},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.17967671155929565},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.11582273244857788}],"concepts":[{"id":"https://openalex.org/C44154001","wikidata":"https://www.wikidata.org/wiki/Q754940","display_name":"Mean time between failures","level":3,"score":0.9734035134315491},{"id":"https://openalex.org/C52121051","wikidata":"https://www.wikidata.org/wiki/Q43193","display_name":"Truck","level":2,"score":0.7706791162490845},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.6211475729942322},{"id":"https://openalex.org/C23725684","wikidata":"https://www.wikidata.org/wiki/Q616377","display_name":"Maintenance engineering","level":2,"score":0.5576514601707458},{"id":"https://openalex.org/C11394606","wikidata":"https://www.wikidata.org/wiki/Q1972552","display_name":"Hydraulic machinery","level":2,"score":0.5256836414337158},{"id":"https://openalex.org/C168167062","wikidata":"https://www.wikidata.org/wiki/Q1117970","display_name":"Component (thermodynamics)","level":2,"score":0.5152673721313477},{"id":"https://openalex.org/C24090081","wikidata":"https://www.wikidata.org/wiki/Q1043452","display_name":"Preventive maintenance","level":2,"score":0.49304887652397156},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.4776771664619446},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4541376233100891},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4282014071941376},{"id":"https://openalex.org/C2994103380","wikidata":"https://www.wikidata.org/wiki/Q766401","display_name":"Copper mine","level":3,"score":0.42624717950820923},{"id":"https://openalex.org/C163164238","wikidata":"https://www.wikidata.org/wiki/Q2737027","display_name":"Failure rate","level":2,"score":0.20599365234375},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.17967671155929565},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.11582273244857788},{"id":"https://openalex.org/C544778455","wikidata":"https://www.wikidata.org/wiki/Q753","display_name":"Copper","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C178790620","wikidata":"https://www.wikidata.org/wiki/Q11351","display_name":"Organic chemistry","level":1,"score":0.0},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ecai.2018.8679066","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ecai.2018.8679066","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 10th International Conference on Electronics, Computers and Artificial Intelligence (ECAI)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W968809127","https://openalex.org/W1495461119","https://openalex.org/W1540454418","https://openalex.org/W1992155567","https://openalex.org/W2079340987","https://openalex.org/W2223317234","https://openalex.org/W2313848746","https://openalex.org/W2511963431","https://openalex.org/W6631974326"],"related_works":["https://openalex.org/W2315243270","https://openalex.org/W1548382899","https://openalex.org/W3202062050","https://openalex.org/W2168011386","https://openalex.org/W2938469583","https://openalex.org/W2130822275","https://openalex.org/W4402668139","https://openalex.org/W2151332743","https://openalex.org/W3217027009","https://openalex.org/W2624804828"],"abstract_inverted_index":{"Computer-aided":[0],"systems":[1],"appliance":[2,52],"to":[3,17,34,39,59,81],"maintenance":[4,62],"is":[5],"a":[6,12,61,110],"known":[7],"problem":[8],"and":[9,91,99,128],"there":[10],"are":[11,25,95],"lot":[13],"of":[14,23,53,85,87,102,113,116,124],"programs":[15],"dedicated":[16],"supporting":[18],"it.":[19],"Although,":[20],"the":[21,51,83,114,121,125],"majority":[22],"them":[24],"based":[26,96],"only":[27],"on":[28,97],"time":[29,33,38,44],"indicators":[30],"like":[31],"mean":[32,37,43],"repair":[35],"(MTTR),":[36],"failure":[40,103],"(MTTF)":[41],"or":[42],"between":[45],"failures":[46,86,117],"(MTBF).":[47],"This":[48],"article":[49,108],"presents":[50,109],"Computerised":[54],"Maintenance":[55],"Management":[56],"System":[57],"(CMMS)":[58],"support":[60],"in":[63,72],"KGHM":[64],"Polska":[65],"Miedi":[66],"S.A":[67],"-":[68,132],"copper":[69],"mining":[70,88],"industry":[71],"Poland.":[73],"It's":[74],"realized":[75],"by":[76],"using":[77],"data":[78,101],"from":[79,105],"CMMS":[80],"calculate":[82],"intensity":[84,115],"machines":[89],"components":[90],"systems.":[92],"The":[93,107],"calculations":[94],"quantitative":[98],"qualitative":[100],"proceed":[104],"CMMS.":[106],"case":[111],"study":[112],"level":[118],"analysis":[119],"for":[120],"hydraulic":[122,133],"system":[123],"haul":[126],"trucks":[127],"its":[129],"selected":[130],"component":[131],"pump.":[134]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2020,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
