{"id":"https://openalex.org/W2073359355","doi":"https://doi.org/10.1109/dest.2013.6611339","title":"Real-time building occupancy sensing using neural-network based sensor network","display_name":"Real-time building occupancy sensing using neural-network based sensor network","publication_year":2013,"publication_date":"2013-07-01","ids":{"openalex":"https://openalex.org/W2073359355","doi":"https://doi.org/10.1109/dest.2013.6611339","mag":"2073359355"},"language":"en","primary_location":{"id":"doi:10.1109/dest.2013.6611339","is_oa":false,"landing_page_url":"https://doi.org/10.1109/dest.2013.6611339","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 7th IEEE International Conference on Digital Ecosystems and Technologies (DEST)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5088671133","display_name":"Tobore Ekwevugbe","orcid":null},"institutions":[{"id":"https://openalex.org/I66943878","display_name":"De Montfort University","ror":"https://ror.org/0312pnr83","country_code":"GB","type":"education","lineage":["https://openalex.org/I66943878"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Tobore Ekwevugbe","raw_affiliation_strings":["Institute of Energy and Sustainable Development, De Montfort University, Leicester, UK","Inst. of Energy & Sustainable Dev., De Montfort Univ. Leicester, Leicester, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Energy and Sustainable Development, De Montfort University, Leicester, UK","institution_ids":["https://openalex.org/I66943878"]},{"raw_affiliation_string":"Inst. of Energy & Sustainable Dev., De Montfort Univ. Leicester, Leicester, UK","institution_ids":["https://openalex.org/I66943878"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5064284504","display_name":"Neil Brown","orcid":"https://orcid.org/0000-0002-7350-4555"},"institutions":[{"id":"https://openalex.org/I66943878","display_name":"De Montfort University","ror":"https://ror.org/0312pnr83","country_code":"GB","type":"education","lineage":["https://openalex.org/I66943878"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Neil Brown","raw_affiliation_strings":["Institute of Energy and Sustainable Development, De Montfort University, Leicester, UK","Inst. of Energy & Sustainable Dev., De Montfort Univ. Leicester, Leicester, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Energy and Sustainable Development, De Montfort University, Leicester, UK","institution_ids":["https://openalex.org/I66943878"]},{"raw_affiliation_string":"Inst. of Energy & Sustainable Dev., De Montfort Univ. Leicester, Leicester, UK","institution_ids":["https://openalex.org/I66943878"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5087361833","display_name":"Vijayanarasimha Hindupur Pakka","orcid":"https://orcid.org/0000-0002-2648-9129"},"institutions":[{"id":"https://openalex.org/I66943878","display_name":"De Montfort University","ror":"https://ror.org/0312pnr83","country_code":"GB","type":"education","lineage":["https://openalex.org/I66943878"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Vijay Pakka","raw_affiliation_strings":["Institute of Energy and Sustainable Development, De Montfort University, Leicester, UK","Inst. of Energy & Sustainable Dev., De Montfort Univ. Leicester, Leicester, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Energy and Sustainable Development, De Montfort University, Leicester, UK","institution_ids":["https://openalex.org/I66943878"]},{"raw_affiliation_string":"Inst. of Energy & Sustainable Dev., De Montfort Univ. Leicester, Leicester, UK","institution_ids":["https://openalex.org/I66943878"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5012346366","display_name":"Denis Fan","orcid":null},"institutions":[{"id":"https://openalex.org/I2799786571","display_name":"Committee on Climate Change","ror":"https://ror.org/00q72x252","country_code":"GB","type":"government","lineage":["https://openalex.org/I2799786571"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Denis Fan","raw_affiliation_strings":["Department of Energy and Climate Change, London, UK","Dept. of Energy & Climate Change, London, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Energy and Climate Change, London, UK","institution_ids":[]},{"raw_affiliation_string":"Dept. of Energy & Climate Change, London, UK","institution_ids":["https://openalex.org/I2799786571"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":4.2817,"has_fulltext":false,"cited_by_count":86,"citation_normalized_percentile":{"value":0.93521275,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":96,"max":100},"biblio":{"volume":null,"issue":null,"first_page":"114","last_page":"119"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9976000189781189,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9976000189781189,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12120","display_name":"Air Quality Monitoring and Forecasting","score":0.9749000072479248,"subfield":{"id":"https://openalex.org/subfields/2305","display_name":"Environmental Engineering"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12256","display_name":"Facilities and Workplace Management","score":0.9564999938011169,"subfield":{"id":"https://openalex.org/subfields/3207","display_name":"Social Psychology"},"field":{"id":"https://openalex.org/fields/32","display_name":"Psychology"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/occupancy","display_name":"Occupancy","score":0.8424637317657471},{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.6347818970680237},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.6185142397880554},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6086358428001404},{"id":"https://openalex.org/keywords/wireless-sensor-network","display_name":"Wireless sensor network","score":0.5263092517852783},{"id":"https://openalex.org/keywords/artificial-neural-network","display_name":"Artificial neural network","score":0.47422099113464355},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.45065850019454956},{"id":"https://openalex.org/keywords/building-automation","display_name":"Building automation","score":0.41006284952163696},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.3341541290283203},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.297037273645401},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2298080325126648},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.17408806085586548},{"id":"https://openalex.org/keywords/architectural-engineering","display_name":"Architectural engineering","score":0.17210018634796143}],"concepts":[{"id":"https://openalex.org/C160331591","wikidata":"https://www.wikidata.org/wiki/Q7075743","display_name":"Occupancy","level":2,"score":0.8424637317657471},{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.6347818970680237},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.6185142397880554},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6086358428001404},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.5263092517852783},{"id":"https://openalex.org/C50644808","wikidata":"https://www.wikidata.org/wiki/Q192776","display_name":"Artificial neural network","level":2,"score":0.47422099113464355},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.45065850019454956},{"id":"https://openalex.org/C83931994","wikidata":"https://www.wikidata.org/wiki/Q1149653","display_name":"Building automation","level":2,"score":0.41006284952163696},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.3341541290283203},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.297037273645401},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2298080325126648},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.17408806085586548},{"id":"https://openalex.org/C170154142","wikidata":"https://www.wikidata.org/wiki/Q150737","display_name":"Architectural engineering","level":1,"score":0.17210018634796143},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/dest.2013.6611339","is_oa":false,"landing_page_url":"https://doi.org/10.1109/dest.2013.6611339","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 7th IEEE International Conference on Digital Ecosystems and Technologies (DEST)","raw_type":"proceedings-article"},{"id":"pmh:oai:dora.dmu.ac.uk:2086/9465","is_oa":false,"landing_page_url":"http://hdl.handle.net/2086/9465","pdf_url":null,"source":{"id":"https://openalex.org/S4306400394","display_name":"DMU Open Research Archive (De Montfort University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I66943878","host_organization_name":"De Montfort University","host_organization_lineage":["https://openalex.org/I66943878"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Conference"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.9100000262260437,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":26,"referenced_works":["https://openalex.org/W1495061682","https://openalex.org/W1972440681","https://openalex.org/W1972669681","https://openalex.org/W1973579937","https://openalex.org/W1994718651","https://openalex.org/W2011741866","https://openalex.org/W2016713803","https://openalex.org/W2035313284","https://openalex.org/W2051670405","https://openalex.org/W2058709726","https://openalex.org/W2068936964","https://openalex.org/W2096911494","https://openalex.org/W2105251341","https://openalex.org/W2107406777","https://openalex.org/W2112021193","https://openalex.org/W2113291960","https://openalex.org/W2133990480","https://openalex.org/W2147294149","https://openalex.org/W2156571267","https://openalex.org/W2160011548","https://openalex.org/W2163121678","https://openalex.org/W2562492610","https://openalex.org/W2588283961","https://openalex.org/W4285719527","https://openalex.org/W6682904970","https://openalex.org/W6731386811"],"related_works":["https://openalex.org/W3045934583","https://openalex.org/W2437015738","https://openalex.org/W4283833227","https://openalex.org/W3093054803","https://openalex.org/W3046823714","https://openalex.org/W2348218441","https://openalex.org/W3021806226","https://openalex.org/W2544143187","https://openalex.org/W2735458449","https://openalex.org/W2749654269"],"abstract_inverted_index":{"Current":[0],"occupancy":[1,49,107,119],"sensing":[2,46],"technologies":[3],"may":[4,38],"limit":[5],"the":[6],"effectiveness":[7],"of":[8,15,31,52,57],"buildings":[9],"controls,":[10],"due":[11],"to":[12,105,115,134,156],"a":[13,42,130,146],"number":[14],"issues":[16],"ranging":[17],"from":[18],"unreliable":[19],"data,":[20],"sensor":[21,81,138],"drift,":[22],"privacy":[23],"concerns,":[24],"and":[25,34,44,59,66,74,79,103,129,173],"insufficient":[26],"commissioning.":[27],"More":[28],"effective":[29],"control":[30,172],"Heating,":[32],"Ventilation":[33],"Air-conditioning":[35],"(HVAC)":[36],"systems":[37],"be":[39],"possible":[40],"using":[41,145],"smart":[43],"adaptive":[45],"network":[47,82],"for":[48,126,158,169],"detection,":[50],"capable":[51],"turning":[53],"off":[54],"services":[55],"out":[56],"hours,":[58],"not":[60,67],"over-ventilating,":[61],"thus":[62],"enabling":[63],"energy":[64,174],"savings,":[65],"under-ventilating":[68],"during":[69],"occupied":[70,159],"periods,":[71],"giving":[72],"comfort":[73,171],"health":[75],"benefits.":[76],"A":[77],"low-cost":[78],"non-intrusive":[80],"was":[83,113,124,161],"deployed":[84],"in":[85,176],"an":[86,110,136],"open-plan":[87],"office,":[88],"combining":[89],"information":[90],"such":[91],"as":[92],"sound":[93],"level,":[94],"case":[95],"temperature,":[96],"carbon-dioxide":[97],"(Co":[98],"<sub":[99],"xmlns:mml=\"http://www.w3.org/1998/Math/MathML\"":[100],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">2</sub>":[101],")":[102],"motion,":[104],"estimate":[106],"numbers,":[108],"while":[109],"infrared":[111],"camera":[112],"implemented":[114],"establish":[116],"ground":[117],"truth":[118],"levels.":[120],"Symmetrical":[121],"uncertainty":[122],"analysis":[123],"used":[125],"feature":[127],"selection,":[128],"genetic":[131],"based":[132],"search":[133],"evaluate":[135],"optimal":[137],"combination.":[139],"Selected":[140],"multi-sensory":[141],"features":[142],"were":[143],"fused":[144],"neural":[147],"network.":[148],"From":[149],"initial":[150],"results,":[151],"estimation":[152],"accuracy":[153],"reaching":[154],"up":[155],"75%":[157],"periods":[160],"achieved.":[162],"The":[163],"proposed":[164],"system":[165],"offers":[166],"promising":[167],"opportunities":[168],"improved":[170],"efficiency":[175],"buildings.":[177]},"counts_by_year":[{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":3},{"year":2023,"cited_by_count":7},{"year":2022,"cited_by_count":9},{"year":2021,"cited_by_count":8},{"year":2020,"cited_by_count":4},{"year":2019,"cited_by_count":13},{"year":2018,"cited_by_count":14},{"year":2017,"cited_by_count":16},{"year":2016,"cited_by_count":5},{"year":2015,"cited_by_count":4}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
