{"id":"https://openalex.org/W2151948696","doi":"https://doi.org/10.1109/dbta.2010.5659016","title":"A Novel Bus Protection Based on Transient Energy of Voltage Traveling Wave and Current Traveling Wave","display_name":"A Novel Bus Protection Based on Transient Energy of Voltage Traveling Wave and Current Traveling Wave","publication_year":2010,"publication_date":"2010-11-01","ids":{"openalex":"https://openalex.org/W2151948696","doi":"https://doi.org/10.1109/dbta.2010.5659016","mag":"2151948696"},"language":"en","primary_location":{"id":"doi:10.1109/dbta.2010.5659016","is_oa":false,"landing_page_url":"https://doi.org/10.1109/dbta.2010.5659016","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2010 2nd International Workshop on Database Technology and Applications","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5089212239","display_name":"Hongchun Shu","orcid":"https://orcid.org/0009-0001-1471-7040"},"institutions":[{"id":"https://openalex.org/I10660446","display_name":"Kunming University of Science and Technology","ror":"https://ror.org/00xyeez13","country_code":"CN","type":"education","lineage":["https://openalex.org/I10660446"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Hongchun Shu","raw_affiliation_strings":["Fac. of Electr. Eng., Kunming Univ. of Sci. & Technol., Kunming, China"],"affiliations":[{"raw_affiliation_string":"Fac. of Electr. Eng., Kunming Univ. of Sci. & Technol., Kunming, China","institution_ids":["https://openalex.org/I10660446"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108214466","display_name":"Yuetao Dai","orcid":null},"institutions":[{"id":"https://openalex.org/I10660446","display_name":"Kunming University of Science and Technology","ror":"https://ror.org/00xyeez13","country_code":"CN","type":"education","lineage":["https://openalex.org/I10660446"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yuetao Dai","raw_affiliation_strings":["Fac. of Electr. Eng., Kunming Univ. of Sci. & Technol., Kunming, China"],"affiliations":[{"raw_affiliation_string":"Fac. of Electr. Eng., Kunming Univ. of Sci. & Technol., Kunming, China","institution_ids":["https://openalex.org/I10660446"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101696820","display_name":"Xincui Tian","orcid":"https://orcid.org/0000-0001-5716-9796"},"institutions":[{"id":"https://openalex.org/I10660446","display_name":"Kunming University of Science and Technology","ror":"https://ror.org/00xyeez13","country_code":"CN","type":"education","lineage":["https://openalex.org/I10660446"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xincui Tian","raw_affiliation_strings":["Fac. of Electr. Eng., Kunming Univ. of Sci. & Technol., Kunming, China"],"affiliations":[{"raw_affiliation_string":"Fac. of Electr. Eng., Kunming Univ. of Sci. & Technol., Kunming, China","institution_ids":["https://openalex.org/I10660446"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5089212239"],"corresponding_institution_ids":["https://openalex.org/I10660446"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.14917653,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":"34","issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9973000288009644,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9973000288009644,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9941999912261963,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.9916999936103821,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/transient","display_name":"Transient (computer programming)","score":0.7789347171783447},{"id":"https://openalex.org/keywords/traveling-wave","display_name":"Traveling wave","score":0.6677344441413879},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.6185230016708374},{"id":"https://openalex.org/keywords/electric-power-transmission","display_name":"Electric power transmission","score":0.5468395352363586},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.540805459022522},{"id":"https://openalex.org/keywords/lightning","display_name":"Lightning (connector)","score":0.5341863632202148},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.5296340584754944},{"id":"https://openalex.org/keywords/transmission-line","display_name":"Transmission line","score":0.501746654510498},{"id":"https://openalex.org/keywords/transient-voltage-suppressor","display_name":"Transient voltage suppressor","score":0.5002756118774414},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4898225963115692},{"id":"https://openalex.org/keywords/emtp","display_name":"Emtp","score":0.46419182419776917},{"id":"https://openalex.org/keywords/busbar","display_name":"Busbar","score":0.4362376034259796},{"id":"https://openalex.org/keywords/power-system-protection","display_name":"Power-system protection","score":0.42272594571113586},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.4152565896511078},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.41444215178489685},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3429718017578125},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.3202871084213257},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.16702058911323547},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.10336419939994812}],"concepts":[{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.7789347171783447},{"id":"https://openalex.org/C2988173416","wikidata":"https://www.wikidata.org/wiki/Q37172","display_name":"Traveling wave","level":2,"score":0.6677344441413879},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6185230016708374},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.5468395352363586},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.540805459022522},{"id":"https://openalex.org/C69398868","wikidata":"https://www.wikidata.org/wiki/Q129052","display_name":"Lightning (connector)","level":3,"score":0.5341863632202148},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5296340584754944},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.501746654510498},{"id":"https://openalex.org/C14915586","wikidata":"https://www.wikidata.org/wiki/Q1653998","display_name":"Transient voltage suppressor","level":3,"score":0.5002756118774414},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4898225963115692},{"id":"https://openalex.org/C2778363592","wikidata":"https://www.wikidata.org/wiki/Q5374837","display_name":"Emtp","level":4,"score":0.46419182419776917},{"id":"https://openalex.org/C192690417","wikidata":"https://www.wikidata.org/wiki/Q1030817","display_name":"Busbar","level":2,"score":0.4362376034259796},{"id":"https://openalex.org/C38361682","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Power-system protection","level":4,"score":0.42272594571113586},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.4152565896511078},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.41444215178489685},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3429718017578125},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.3202871084213257},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.16702058911323547},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.10336419939994812},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/dbta.2010.5659016","is_oa":false,"landing_page_url":"https://doi.org/10.1109/dbta.2010.5659016","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2010 2nd International Workshop on Database Technology and Applications","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W1624675529","https://openalex.org/W2361180442","https://openalex.org/W2372114617","https://openalex.org/W2382606928","https://openalex.org/W7071003169"],"related_works":["https://openalex.org/W2162763722","https://openalex.org/W2892589709","https://openalex.org/W1860673961","https://openalex.org/W2135690429","https://openalex.org/W2027070556","https://openalex.org/W4229656550","https://openalex.org/W2035819079","https://openalex.org/W2953003060","https://openalex.org/W2513150050","https://openalex.org/W2554622337"],"abstract_inverted_index":{"The":[0],"protection":[1,15,34,82,88],"based":[2,35],"on":[3,36,48,98],"fault":[4],"transient":[5,37,72],"component":[6],"could":[7],"overcome":[8],"the":[9,40,54,57,80],"disadvantages":[10],"of":[11,59,62],"traditional":[12],"industrial":[13],"frequency":[14],"such":[16],"as":[17,101],"poor":[18],"anti-CT":[19],"saturation":[20],"ability":[21],"and":[22,44,85],"long":[23],"operating":[24],"time.This":[25],"paper":[26],"presents":[27],"a":[28],"novel":[29],"ultra":[30],"high":[31],"speed":[32],"bus":[33,63,81,87,102],"energy,which":[38],"takes":[39],"voltage":[41],"traveling":[42,46],"wave":[43,47],"current":[45],"each":[49],"transmission":[50,99],"line":[51],"to":[52],"calculate":[53],"energy,":[55],"with":[56,70],"purpose":[58],"accurate":[60],"identification":[61],"internal":[64],"fault.":[65],"Simulation":[66],"is":[67,83],"carried":[68],"out":[69],"electromagnetic":[71],"simulation":[73,76],"software":[74],"PSCAD/EMTDC,the":[75],"result":[77],"verifies":[78],"that":[79],"reliable":[84],"accurate.The":[86],"also":[89],"can":[90],"treat":[91],"lightning":[92,95],"failure":[93],"or":[94],"disturbance":[96],"happened":[97],"lines":[100],"external":[103],"fault,without":[104],"malfunction.":[105]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":3}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
