{"id":"https://openalex.org/W2072566983","doi":"https://doi.org/10.1109/date.2011.5763132","title":"Interconnect-fault-resilient delay-insensitive asynchronous communication link based on current-flow monitoring","display_name":"Interconnect-fault-resilient delay-insensitive asynchronous communication link based on current-flow monitoring","publication_year":2011,"publication_date":"2011-03-01","ids":{"openalex":"https://openalex.org/W2072566983","doi":"https://doi.org/10.1109/date.2011.5763132","mag":"2072566983"},"language":"en","primary_location":{"id":"doi:10.1109/date.2011.5763132","is_oa":false,"landing_page_url":"https://doi.org/10.1109/date.2011.5763132","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 Design, Automation &amp; Test in Europe","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5049740452","display_name":"Naoya Onizawa","orcid":"https://orcid.org/0000-0002-4855-7081"},"institutions":[{"id":"https://openalex.org/I201537933","display_name":"Tohoku University","ror":"https://ror.org/01dq60k83","country_code":"JP","type":"education","lineage":["https://openalex.org/I201537933"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"N Onizawa","raw_affiliation_strings":["Research Institute of Electrical Communication, University of Tohoku, Sendai, Miyagi, Japan","Research Institute of Electrical Communication, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai, Miyagi, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Research Institute of Electrical Communication, University of Tohoku, Sendai, Miyagi, Japan","institution_ids":[]},{"raw_affiliation_string":"Research Institute of Electrical Communication, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai, Miyagi, Japan","institution_ids":["https://openalex.org/I201537933"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101503249","display_name":"Atsushi Matsumoto","orcid":"https://orcid.org/0000-0003-0885-6957"},"institutions":[{"id":"https://openalex.org/I201537933","display_name":"Tohoku University","ror":"https://ror.org/01dq60k83","country_code":"JP","type":"education","lineage":["https://openalex.org/I201537933"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"A Matsumoto","raw_affiliation_strings":["Research Institute of Electrical Communication, University of Tohoku, Sendai, Miyagi, Japan","Research Institute of Electrical Communication, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai, Miyagi, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Research Institute of Electrical Communication, University of Tohoku, Sendai, Miyagi, Japan","institution_ids":[]},{"raw_affiliation_string":"Research Institute of Electrical Communication, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai, Miyagi, Japan","institution_ids":["https://openalex.org/I201537933"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5062434040","display_name":"Takahiro Hanyu","orcid":"https://orcid.org/0000-0002-4397-8290"},"institutions":[{"id":"https://openalex.org/I201537933","display_name":"Tohoku University","ror":"https://ror.org/01dq60k83","country_code":"JP","type":"education","lineage":["https://openalex.org/I201537933"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"T Hanyu","raw_affiliation_strings":["Research Institute of Electrical Communication, University of Tohoku, Sendai, Miyagi, Japan","Research Institute of Electrical Communication, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai, Miyagi, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Research Institute of Electrical Communication, University of Tohoku, Sendai, Miyagi, Japan","institution_ids":[]},{"raw_affiliation_string":"Research Institute of Electrical Communication, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai, Miyagi, Japan","institution_ids":["https://openalex.org/I201537933"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I201537933"],"apc_list":null,"apc_paid":null,"fwci":0.286,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.45906074,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"32","issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10829","display_name":"Interconnection Networks and Systems","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10829","display_name":"Interconnection Networks and Systems","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10363","display_name":"Low-power high-performance VLSI design","score":0.9945999979972839,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10018","display_name":"Advancements in Battery Materials","score":0.9930999875068665,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/asynchronous-communication","display_name":"Asynchronous communication","score":0.726425051689148},{"id":"https://openalex.org/keywords/interconnection","display_name":"Interconnection","score":0.6153481602668762},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5927342772483826},{"id":"https://openalex.org/keywords/redundancy","display_name":"Redundancy (engineering)","score":0.5175139904022217},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4834464490413666},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.43216705322265625},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.41327595710754395},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3092188239097595},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.2270946502685547}],"concepts":[{"id":"https://openalex.org/C151319957","wikidata":"https://www.wikidata.org/wiki/Q752739","display_name":"Asynchronous communication","level":2,"score":0.726425051689148},{"id":"https://openalex.org/C123745756","wikidata":"https://www.wikidata.org/wiki/Q1665949","display_name":"Interconnection","level":2,"score":0.6153481602668762},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5927342772483826},{"id":"https://openalex.org/C152124472","wikidata":"https://www.wikidata.org/wiki/Q1204361","display_name":"Redundancy (engineering)","level":2,"score":0.5175139904022217},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4834464490413666},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.43216705322265625},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.41327595710754395},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3092188239097595},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.2270946502685547},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/date.2011.5763132","is_oa":false,"landing_page_url":"https://doi.org/10.1109/date.2011.5763132","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 Design, Automation &amp; Test in Europe","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.9100000262260437}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W1979429199","https://openalex.org/W2031933249","https://openalex.org/W2117722882","https://openalex.org/W2121883482","https://openalex.org/W2144709243","https://openalex.org/W2147657871","https://openalex.org/W2147915525","https://openalex.org/W2152385473","https://openalex.org/W2160642395","https://openalex.org/W2165131636","https://openalex.org/W2535178133","https://openalex.org/W3150832729","https://openalex.org/W4248489181","https://openalex.org/W4251296695","https://openalex.org/W6684545260","https://openalex.org/W6830497948"],"related_works":["https://openalex.org/W2116677773","https://openalex.org/W2155261584","https://openalex.org/W2584231425","https://openalex.org/W2042919702","https://openalex.org/W2155019192","https://openalex.org/W2150611273","https://openalex.org/W2014709025","https://openalex.org/W4207086172","https://openalex.org/W2578404781","https://openalex.org/W2065965834"],"abstract_inverted_index":{"Delay-insensitive":[0],"asynchronous":[1,14,41,109],"on-chip":[2],"communication":[3,42,110],"links":[4],"are":[5,138],"a":[6,11,19,29,70,74,99,104,124],"key":[7],"element":[8],"to":[9,69,85,115,140],"realize":[10],"highly":[12],"reliable":[13],"Network-on-Chip":[15],"system.":[16,34],"However,":[17],"even":[18],"single":[20],"permanent":[21],"fault,":[22,27],"such":[23],"as":[24],"an":[25,38,52,58],"interconnect":[26,53,88,117],"causes":[28],"deadlock":[30],"state":[31],"in":[32,61,145],"the":[33,62,64,79,87,116,120,126,130,135,150],"This":[35],"paper":[36],"presents":[37],"interconnect-fault-resilient":[39],"delay-insensitive":[40],"link":[43,95,111,137],"based":[44],"on":[45],"current-flow":[46],"monitoring.":[47],"Since":[48],"current":[49,65,76,81],"flow":[50],"upon":[51],"is":[54,66,96,113],"cut":[55],"off":[56],"by":[57,98],"open":[59],"fault":[60,89,118],"interconnect,":[63],"fed":[67],"back":[68],"transmitter,":[71],"which":[72,112],"increases":[73],"feedback":[75,80],"monotonically.":[77],"Monitoring":[78],"makes":[82],"it":[83],"possible":[84],"detect":[86],"with":[90,103,147],"delay":[91,121],"insensitivity.":[92,122],"The":[93],"proposed":[94,136],"evaluated":[97],"0.13\u03bcm":[100],"CMOS":[101],"technology":[102],"Triple":[105],"Modular":[106],"Redundancy":[107],"(TMR)-based":[108],"resilient":[114],"without":[119],"As":[123],"result,":[125],"energy":[127],"consumption":[128],"and":[129,142],"number":[131],"of":[132,134,149],"wires":[133],"reduced":[139],"57%":[141],"33%,":[143],"respectively,":[144],"comparison":[146],"those":[148],"conventional":[151],"one.":[152]},"counts_by_year":[{"year":2013,"cited_by_count":1}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
