{"id":"https://openalex.org/W2625207495","doi":"https://doi.org/10.1109/comsnets.2017.7945448","title":"Temperature sensor based ultra low cost respiration monitoring system","display_name":"Temperature sensor based ultra low cost respiration monitoring system","publication_year":2017,"publication_date":"2017-01-01","ids":{"openalex":"https://openalex.org/W2625207495","doi":"https://doi.org/10.1109/comsnets.2017.7945448","mag":"2625207495"},"language":"en","primary_location":{"id":"doi:10.1109/comsnets.2017.7945448","is_oa":false,"landing_page_url":"https://doi.org/10.1109/comsnets.2017.7945448","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 9th International Conference on Communication Systems and Networks (COMSNETS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5079393112","display_name":"Anshul Basra","orcid":null},"institutions":[{"id":"https://openalex.org/I36909309","display_name":"National Institute of Technology Hamirpur","ror":"https://ror.org/01nc8zs04","country_code":"IN","type":"education","lineage":["https://openalex.org/I36909309","https://openalex.org/I4210152752"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Anshul Basra","raw_affiliation_strings":["Department of ECE, NIT, Hamirpur, Himachal Pradesh"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of ECE, NIT, Hamirpur, Himachal Pradesh","institution_ids":["https://openalex.org/I36909309"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5013668614","display_name":"Bodhibrata Mukhopadhayay","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Bodhibrata Mukhopadhayay","raw_affiliation_strings":["Department of Electrical Engineering"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5072608867","display_name":"Subrat Kar","orcid":"https://orcid.org/0000-0002-2845-5598"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Subrat Kar","raw_affiliation_strings":["IIT, Bharti School of Telecommunication Technology and Management, Delhi"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"IIT, Bharti School of Telecommunication Technology and Management, Delhi","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.6563,"has_fulltext":false,"cited_by_count":28,"citation_normalized_percentile":{"value":0.67550884,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"530","last_page":"535"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9979000091552734,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9979000091552734,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11667","display_name":"Advanced Chemical Sensor Technologies","score":0.9904000163078308,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12222","display_name":"IoT-based Smart Home Systems","score":0.9805999994277954,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/exhalation","display_name":"Exhalation","score":0.7619360685348511},{"id":"https://openalex.org/keywords/respiration","display_name":"Respiration","score":0.7072035074234009},{"id":"https://openalex.org/keywords/respiratory-rate","display_name":"Respiratory rate","score":0.6860394477844238},{"id":"https://openalex.org/keywords/respiratory-monitoring","display_name":"Respiratory monitoring","score":0.6113343834877014},{"id":"https://openalex.org/keywords/tachypnea","display_name":"Tachypnea","score":0.593888521194458},{"id":"https://openalex.org/keywords/microcontroller","display_name":"Microcontroller","score":0.5235440731048584},{"id":"https://openalex.org/keywords/respiratory-system","display_name":"Respiratory system","score":0.4703875780105591},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4170289635658264},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.35085999965667725},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.3422226011753082},{"id":"https://openalex.org/keywords/anesthesia","display_name":"Anesthesia","score":0.29356247186660767},{"id":"https://openalex.org/keywords/heart-rate","display_name":"Heart rate","score":0.2708130478858948},{"id":"https://openalex.org/keywords/computer-hardware","display_name":"Computer hardware","score":0.22487956285476685},{"id":"https://openalex.org/keywords/internal-medicine","display_name":"Internal medicine","score":0.16589772701263428},{"id":"https://openalex.org/keywords/tachycardia","display_name":"Tachycardia","score":0.08223500847816467}],"concepts":[{"id":"https://openalex.org/C43396882","wikidata":"https://www.wikidata.org/wiki/Q2197000","display_name":"Exhalation","level":2,"score":0.7619360685348511},{"id":"https://openalex.org/C182215343","wikidata":"https://www.wikidata.org/wiki/Q472287","display_name":"Respiration","level":2,"score":0.7072035074234009},{"id":"https://openalex.org/C8213797","wikidata":"https://www.wikidata.org/wiki/Q754250","display_name":"Respiratory rate","level":4,"score":0.6860394477844238},{"id":"https://openalex.org/C2779358675","wikidata":"https://www.wikidata.org/wiki/Q3766250","display_name":"Respiratory monitoring","level":3,"score":0.6113343834877014},{"id":"https://openalex.org/C2778312941","wikidata":"https://www.wikidata.org/wiki/Q570920","display_name":"Tachypnea","level":3,"score":0.593888521194458},{"id":"https://openalex.org/C173018170","wikidata":"https://www.wikidata.org/wiki/Q165678","display_name":"Microcontroller","level":2,"score":0.5235440731048584},{"id":"https://openalex.org/C534529494","wikidata":"https://www.wikidata.org/wiki/Q7891","display_name":"Respiratory system","level":2,"score":0.4703875780105591},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4170289635658264},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.35085999965667725},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.3422226011753082},{"id":"https://openalex.org/C42219234","wikidata":"https://www.wikidata.org/wiki/Q131130","display_name":"Anesthesia","level":1,"score":0.29356247186660767},{"id":"https://openalex.org/C2777953023","wikidata":"https://www.wikidata.org/wiki/Q1073121","display_name":"Heart rate","level":3,"score":0.2708130478858948},{"id":"https://openalex.org/C9390403","wikidata":"https://www.wikidata.org/wiki/Q3966","display_name":"Computer hardware","level":1,"score":0.22487956285476685},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.16589772701263428},{"id":"https://openalex.org/C2780283014","wikidata":"https://www.wikidata.org/wiki/Q209583","display_name":"Tachycardia","level":2,"score":0.08223500847816467},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.0},{"id":"https://openalex.org/C105702510","wikidata":"https://www.wikidata.org/wiki/Q514","display_name":"Anatomy","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/comsnets.2017.7945448","is_oa":false,"landing_page_url":"https://doi.org/10.1109/comsnets.2017.7945448","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 9th International Conference on Communication Systems and Networks (COMSNETS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","display_name":"Good health and well-being","score":0.5699999928474426}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W1483972508","https://openalex.org/W2130583484","https://openalex.org/W2164996269","https://openalex.org/W2470936712"],"related_works":["https://openalex.org/W2080720724","https://openalex.org/W1618785394","https://openalex.org/W2057211515","https://openalex.org/W4396745981","https://openalex.org/W3188647568","https://openalex.org/W2347202109","https://openalex.org/W2033873274","https://openalex.org/W2091047331","https://openalex.org/W2057257177","https://openalex.org/W4322616726"],"abstract_inverted_index":{"Measurement":[0],"of":[1,20,52],"respiration":[2,14,131],"rate":[3,15,95,112],"is":[4],"a":[5,18,32,63,96],"vital":[6],"parameter":[7],"for":[8,117],"adequate":[9],"health":[10],"monitoring.":[11],"An":[12],"abnormal":[13,130],"can":[16,78,122],"indicate":[17],"variety":[19],"pathological":[21],"conditions":[22],"like":[23,81],"respiratory,":[24],"cardiovascular":[25],"and":[26,38,49,84,129],"metabolic":[27],"disorders.":[28],"We":[29],"have":[30],"developed":[31],"non-invasive,":[33],"portable,":[34],"easy":[35],"to":[36,108,125],"use":[37],"economic":[39],"respiratory":[40,53,94,111],"sensor.":[41],"It":[42],"measures":[43],"the":[44,74,88,103,109,118],"temperature":[45,58],"difference":[46,56],"between":[47],"inhalation":[48],"exhalation":[50],"phases":[51],"cycle.":[54],"The":[55],"in":[57,93],"has":[59,99,113],"been":[60,100,114],"converted":[61],"into":[62],"digital":[64,75],"signal":[65],"using":[66],"8":[67],"bit":[68],"microcontroller":[69],"(Atmega":[70],"328).":[71],"By":[72],"analyzing":[73],"signal,":[76],"we":[77],"detect":[79,126],"abnormalities":[80],"tachypnea,":[82],"bradypnea":[83],"apnea.":[85],"To":[86],"track":[87],"unusual":[89],"or":[90],"sudden":[91],"change":[92],"buzzer":[97],"system":[98],"incorporated":[101],"with":[102],"device.":[104],"Graphical":[105],"recordings":[106],"corresponding":[107],"calculated":[110],"simultaneously":[115],"obtained":[116],"reference.":[119],"This":[120],"device":[121],"be":[123],"used":[124],"sleeping":[127],"disorder":[128],"rate.":[132]},"counts_by_year":[{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":6},{"year":2023,"cited_by_count":7},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":4},{"year":2018,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
