{"id":"https://openalex.org/W2107615539","doi":"https://doi.org/10.1109/compeng.2012.6242949","title":"Protection system monitoring for the prevention of cascading events in smart transmission grids","display_name":"Protection system monitoring for the prevention of cascading events in smart transmission grids","publication_year":2012,"publication_date":"2012-06-01","ids":{"openalex":"https://openalex.org/W2107615539","doi":"https://doi.org/10.1109/compeng.2012.6242949","mag":"2107615539"},"language":"en","primary_location":{"id":"doi:10.1109/compeng.2012.6242949","is_oa":false,"landing_page_url":"https://doi.org/10.1109/compeng.2012.6242949","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 Complexity in Engineering (COMPENG). Proceedings","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5016158215","display_name":"S\u00e9rgio Bruno","orcid":"https://orcid.org/0000-0003-0863-9274"},"institutions":[{"id":"https://openalex.org/I68618741","display_name":"Polytechnic University of Bari","ror":"https://ror.org/03c44v465","country_code":"IT","type":"education","lineage":["https://openalex.org/I68618741"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Sergio Bruno","raw_affiliation_strings":["Politecnico di Bari, DEE, Bari, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Politecnico di Bari, DEE, Bari, Italy","institution_ids":["https://openalex.org/I68618741"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5089400790","display_name":"Matteo D\u2019Aloia","orcid":null},"institutions":[{"id":"https://openalex.org/I68618741","display_name":"Polytechnic University of Bari","ror":"https://ror.org/03c44v465","country_code":"IT","type":"education","lineage":["https://openalex.org/I68618741"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Matteo D'Aloia","raw_affiliation_strings":["Politecnico di Bari, DEE, Bari, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Politecnico di Bari, DEE, Bari, Italy","institution_ids":["https://openalex.org/I68618741"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5046666240","display_name":"Massimo La Scala","orcid":"https://orcid.org/0000-0002-7257-2599"},"institutions":[{"id":"https://openalex.org/I68618741","display_name":"Polytechnic University of Bari","ror":"https://ror.org/03c44v465","country_code":"IT","type":"education","lineage":["https://openalex.org/I68618741"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Massimo La Scala","raw_affiliation_strings":["Politecnico di Bari, DEE, Bari, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Politecnico di Bari, DEE, Bari, Italy","institution_ids":["https://openalex.org/I68618741"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5023532871","display_name":"Roberto Sbrizzai","orcid":"https://orcid.org/0000-0001-9817-7733"},"institutions":[{"id":"https://openalex.org/I68618741","display_name":"Polytechnic University of Bari","ror":"https://ror.org/03c44v465","country_code":"IT","type":"education","lineage":["https://openalex.org/I68618741"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Roberto Sbrizzai","raw_affiliation_strings":["Politecnico di Bari, DEE, Bari, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Politecnico di Bari, DEE, Bari, Italy","institution_ids":["https://openalex.org/I68618741"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I68618741"],"apc_list":null,"apc_paid":null,"fwci":1.137,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.83388395,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9941999912261963,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/blackout","display_name":"Blackout","score":0.8916379809379578},{"id":"https://openalex.org/keywords/scada","display_name":"SCADA","score":0.7264218330383301},{"id":"https://openalex.org/keywords/dependability","display_name":"Dependability","score":0.7170122861862183},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6562479138374329},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.5518402457237244},{"id":"https://openalex.org/keywords/relay","display_name":"Relay","score":0.5398591756820679},{"id":"https://openalex.org/keywords/iec-61850","display_name":"IEC 61850","score":0.5010309219360352},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.45541855692863464},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.4130322337150574},{"id":"https://openalex.org/keywords/computer-security","display_name":"Computer security","score":0.3814166784286499},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.3780060410499573},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.3465350270271301},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.3403104543685913},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.25657162070274353},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.20886722207069397},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.1697581708431244},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.10938844084739685}],"concepts":[{"id":"https://openalex.org/C2777693866","wikidata":"https://www.wikidata.org/wiki/Q359099","display_name":"Blackout","level":4,"score":0.8916379809379578},{"id":"https://openalex.org/C113863187","wikidata":"https://www.wikidata.org/wiki/Q17498","display_name":"SCADA","level":2,"score":0.7264218330383301},{"id":"https://openalex.org/C77019957","wikidata":"https://www.wikidata.org/wiki/Q2689057","display_name":"Dependability","level":2,"score":0.7170122861862183},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6562479138374329},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.5518402457237244},{"id":"https://openalex.org/C2778156585","wikidata":"https://www.wikidata.org/wiki/Q174053","display_name":"Relay","level":3,"score":0.5398591756820679},{"id":"https://openalex.org/C2778907243","wikidata":"https://www.wikidata.org/wiki/Q168160","display_name":"IEC 61850","level":3,"score":0.5010309219360352},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.45541855692863464},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4130322337150574},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.3814166784286499},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.3780060410499573},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.3465350270271301},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.3403104543685913},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.25657162070274353},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.20886722207069397},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.1697581708431244},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.10938844084739685},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/compeng.2012.6242949","is_oa":false,"landing_page_url":"https://doi.org/10.1109/compeng.2012.6242949","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 Complexity in Engineering (COMPENG). Proceedings","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W1971178525","https://openalex.org/W2008209526","https://openalex.org/W2019220013","https://openalex.org/W2021062361","https://openalex.org/W2076433708","https://openalex.org/W2100259029","https://openalex.org/W2115131727","https://openalex.org/W2118172321","https://openalex.org/W2118865147","https://openalex.org/W2138569723","https://openalex.org/W2182920413","https://openalex.org/W6685903888"],"related_works":["https://openalex.org/W2541651390","https://openalex.org/W2362501786","https://openalex.org/W2369265009","https://openalex.org/W2056229749","https://openalex.org/W1563793854","https://openalex.org/W1970209698","https://openalex.org/W2393075332","https://openalex.org/W2125521484","https://openalex.org/W4375832018","https://openalex.org/W2553754225"],"abstract_inverted_index":{"With":[0],"the":[1,37,65],"diffusion":[2],"of":[3,29,49,67],"standardized":[4],"communication":[5],"protocols":[6],"in":[7,22,52],"smart":[8],"transmission":[9],"systems,":[10],"it":[11],"is":[12,96],"expected":[13],"that":[14,73],"digital":[15],"distance":[16,30,93],"relays":[17,31],"will":[18,33],"become":[19],"active":[20],"elements":[21],"monitoring":[23,69,82],"and":[24,42,55,70,89,101],"control":[25,71],"architecture.":[26],"Real-time":[27],"tuning":[28],"settings":[32],"allow":[34],"to":[35,45,92],"overcome":[36],"classical":[38],"conflict":[39],"between":[40],"dependability":[41],"security,":[43],"or":[44],"avoid":[46],"improper":[47],"operation":[48,100],"such":[50,75],"devices":[51,76],"vulnerable":[53],"conditions":[54],"during":[56],"major":[57],"blackout":[58],"events.":[59],"In":[60],"this":[61],"paper,":[62],"along":[63],"with":[64],"presentation":[66],"a":[68,79],"architecture":[72],"integrates":[74],"into":[77],"SCADA/EMS,":[78],"system":[80,87,99],"security":[81],"function,":[83],"based":[84],"on":[85],"simulated":[86],"trajectories":[88],"their":[90],"closeness":[91],"relay":[94],"zones,":[95],"proposed":[97],"for":[98],"contingency":[102],"analysis.":[103]},"counts_by_year":[{"year":2017,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2012,"cited_by_count":1}],"updated_date":"2026-06-26T08:34:08.712188","created_date":"2025-10-10T00:00:00"}
