{"id":"https://openalex.org/W2769148028","doi":"https://doi.org/10.1109/codit.2017.8102723","title":"Algorithms on improvement of accuracy of biofuel temperature measurement in thermo-anemometric flowmeter","display_name":"Algorithms on improvement of accuracy of biofuel temperature measurement in thermo-anemometric flowmeter","publication_year":2017,"publication_date":"2017-04-01","ids":{"openalex":"https://openalex.org/W2769148028","doi":"https://doi.org/10.1109/codit.2017.8102723","mag":"2769148028"},"language":"en","primary_location":{"id":"doi:10.1109/codit.2017.8102723","is_oa":false,"landing_page_url":"https://doi.org/10.1109/codit.2017.8102723","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 4th International Conference on Control, Decision and Information Technologies (CoDIT)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5048382569","display_name":"Igor Korobiichuk","orcid":"https://orcid.org/0000-0002-5865-7668"},"institutions":[{"id":"https://openalex.org/I4210159392","display_name":"\u0141ukasiewicz Research Network - Industrial Research Institute for Automation and Measurements","ror":"https://ror.org/04b9a1925","country_code":"PL","type":"facility","lineage":["https://openalex.org/I4210159392"]}],"countries":["PL"],"is_corresponding":true,"raw_author_name":"Igor Korobiichuk","raw_affiliation_strings":["Industrial Research Institute for Automation and Measurements PIAP, Warsaw, Poland"],"affiliations":[{"raw_affiliation_string":"Industrial Research Institute for Automation and Measurements PIAP, Warsaw, Poland","institution_ids":["https://openalex.org/I4210159392"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5001250576","display_name":"Maciej Kachniarz","orcid":"https://orcid.org/0000-0001-5349-4081"},"institutions":[{"id":"https://openalex.org/I4210159392","display_name":"\u0141ukasiewicz Research Network - Industrial Research Institute for Automation and Measurements","ror":"https://ror.org/04b9a1925","country_code":"PL","type":"facility","lineage":["https://openalex.org/I4210159392"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Maciej Kachniarz","raw_affiliation_strings":["Industrial Research Institute for Automation and Measurements PIAP, Warsaw, Poland"],"affiliations":[{"raw_affiliation_string":"Industrial Research Institute for Automation and Measurements PIAP, Warsaw, Poland","institution_ids":["https://openalex.org/I4210159392"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5015898781","display_name":"Yurij Shavursky","orcid":null},"institutions":[{"id":"https://openalex.org/I4210149696","display_name":"Zhytomyr Polytechnic State University","ror":"https://ror.org/04r5xzk86","country_code":"UA","type":"education","lineage":["https://openalex.org/I4210149696"]}],"countries":["UA"],"is_corresponding":false,"raw_author_name":"Yurij Shavursky","raw_affiliation_strings":["Zhytomyr State Technological University, Zhytomyr, Ukraine"],"affiliations":[{"raw_affiliation_string":"Zhytomyr State Technological University, Zhytomyr, Ukraine","institution_ids":["https://openalex.org/I4210149696"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5011274414","display_name":"Micha\u0142 Nowicki","orcid":"https://orcid.org/0000-0003-2513-952X"},"institutions":[{"id":"https://openalex.org/I108403487","display_name":"Warsaw University of Technology","ror":"https://ror.org/00y0xnp53","country_code":"PL","type":"education","lineage":["https://openalex.org/I108403487"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Michal Nowicki","raw_affiliation_strings":["Institute of Metrology and Biomedical Engineering, Warsaw University of Technology, Warsaw, Poland"],"affiliations":[{"raw_affiliation_string":"Institute of Metrology and Biomedical Engineering, Warsaw University of Technology, Warsaw, Poland","institution_ids":["https://openalex.org/I108403487"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5078429180","display_name":"Roman Szewczyk","orcid":"https://orcid.org/0000-0002-1214-1009"},"institutions":[{"id":"https://openalex.org/I108403487","display_name":"Warsaw University of Technology","ror":"https://ror.org/00y0xnp53","country_code":"PL","type":"education","lineage":["https://openalex.org/I108403487"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Roman Szewczyk","raw_affiliation_strings":["Institute of Metrology and Biomedical Engineering, Warsaw University of Technology, Warsaw, Poland"],"affiliations":[{"raw_affiliation_string":"Institute of Metrology and Biomedical Engineering, Warsaw University of Technology, Warsaw, Poland","institution_ids":["https://openalex.org/I108403487"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5048382569"],"corresponding_institution_ids":["https://openalex.org/I4210159392"],"apc_list":null,"apc_paid":null,"fwci":0.1684,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.62093977,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":"32","issue":null,"first_page":"0964","last_page":"0968"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T14069","display_name":"Scientific Research Methodologies and Applications","score":0.998199999332428,"subfield":{"id":"https://openalex.org/subfields/2312","display_name":"Water Science and Technology"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T14069","display_name":"Scientific Research Methodologies and Applications","score":0.998199999332428,"subfield":{"id":"https://openalex.org/subfields/2312","display_name":"Water Science and Technology"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13732","display_name":"Aerospace, Electronics, Mathematical Modeling","score":0.958299994468689,"subfield":{"id":"https://openalex.org/subfields/2309","display_name":"Nature and Landscape Conservation"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12710","display_name":"Engineering and Agricultural Innovations","score":0.9150000214576721,"subfield":{"id":"https://openalex.org/subfields/1104","display_name":"Aquatic Science"},"field":{"id":"https://openalex.org/fields/11","display_name":"Agricultural and Biological Sciences"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/flow-measurement","display_name":"Flow measurement","score":0.6853331923484802},{"id":"https://openalex.org/keywords/observational-error","display_name":"Observational error","score":0.6052297353744507},{"id":"https://openalex.org/keywords/temperature-measurement","display_name":"Temperature measurement","score":0.6011767983436584},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.5381990075111389},{"id":"https://openalex.org/keywords/measurement-uncertainty","display_name":"Measurement uncertainty","score":0.5225738286972046},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5217179656028748},{"id":"https://openalex.org/keywords/process","display_name":"Process (computing)","score":0.499467134475708},{"id":"https://openalex.org/keywords/thermal","display_name":"Thermal","score":0.46214210987091064},{"id":"https://openalex.org/keywords/thermoelectric-effect","display_name":"Thermoelectric effect","score":0.4571710228919983},{"id":"https://openalex.org/keywords/flow","display_name":"Flow (mathematics)","score":0.44963663816452026},{"id":"https://openalex.org/keywords/accuracy-and-precision","display_name":"Accuracy and precision","score":0.4485741853713989},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.40764540433883667},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.32037514448165894},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2497941553592682},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.21365872025489807},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.19407856464385986},{"id":"https://openalex.org/keywords/mechanics","display_name":"Mechanics","score":0.16517820954322815},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.10093417763710022},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.08938443660736084},{"id":"https://openalex.org/keywords/thermodynamics","display_name":"Thermodynamics","score":0.08758699893951416}],"concepts":[{"id":"https://openalex.org/C16302685","wikidata":"https://www.wikidata.org/wiki/Q15091623","display_name":"Flow measurement","level":2,"score":0.6853331923484802},{"id":"https://openalex.org/C19619285","wikidata":"https://www.wikidata.org/wiki/Q196372","display_name":"Observational error","level":2,"score":0.6052297353744507},{"id":"https://openalex.org/C72293138","wikidata":"https://www.wikidata.org/wiki/Q909741","display_name":"Temperature measurement","level":2,"score":0.6011767983436584},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.5381990075111389},{"id":"https://openalex.org/C137209882","wikidata":"https://www.wikidata.org/wiki/Q1403517","display_name":"Measurement uncertainty","level":2,"score":0.5225738286972046},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5217179656028748},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.499467134475708},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.46214210987091064},{"id":"https://openalex.org/C63024428","wikidata":"https://www.wikidata.org/wiki/Q552456","display_name":"Thermoelectric effect","level":2,"score":0.4571710228919983},{"id":"https://openalex.org/C38349280","wikidata":"https://www.wikidata.org/wiki/Q1434290","display_name":"Flow (mathematics)","level":2,"score":0.44963663816452026},{"id":"https://openalex.org/C202799725","wikidata":"https://www.wikidata.org/wiki/Q272035","display_name":"Accuracy and precision","level":2,"score":0.4485741853713989},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.40764540433883667},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.32037514448165894},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2497941553592682},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.21365872025489807},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.19407856464385986},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.16517820954322815},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.10093417763710022},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.08938443660736084},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.08758699893951416},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/codit.2017.8102723","is_oa":false,"landing_page_url":"https://doi.org/10.1109/codit.2017.8102723","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 4th International Conference on Control, Decision and Information Technologies (CoDIT)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.8199999928474426}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W1842008762","https://openalex.org/W1865682489","https://openalex.org/W1965745866","https://openalex.org/W1980762885","https://openalex.org/W2003838206","https://openalex.org/W2013115664","https://openalex.org/W2014676799","https://openalex.org/W2137456089","https://openalex.org/W2327065009","https://openalex.org/W2386652959","https://openalex.org/W2521398646","https://openalex.org/W2557452885","https://openalex.org/W4249435698"],"related_works":["https://openalex.org/W2220451197","https://openalex.org/W2370122455","https://openalex.org/W4309995555","https://openalex.org/W2407741852","https://openalex.org/W1600397729","https://openalex.org/W2347604274","https://openalex.org/W1825457241","https://openalex.org/W2360832559","https://openalex.org/W2392627782","https://openalex.org/W2389093041"],"abstract_inverted_index":{"This":[0],"article":[1],"considers":[2],"the":[3,11,35,38,62,115],"errors":[4,22,43,85,96],"of":[5,13,33,41,49,51,67,73,82,93,101,104,109,117],"biofuel":[6],"temperature":[7],"measurement":[8,21,63],"based":[9],"on":[10],"use":[12,100],"thermoelectric":[14],"converter":[15],"in":[16,75,119],"thermo-anemometric":[17,83],"flowmeter.":[18],"Quantitatively,":[19],"these":[20],"are":[23],"represented":[24],"by":[25],"a":[26,70,102,120],"mathematical":[27,80],"model.":[28],"Therefore,":[29],"for":[30,91],"greater":[31],"efficiency":[32],"using":[34,52],"thermal":[36,105],"converters,":[37],"required":[39],"calculations":[40],"TAF":[42,54],"were":[44],"made,":[45],"and":[46,65,88,107,127],"an":[47],"analysis":[48],"feasibility":[50],"this":[53],"was":[55,86,97],"carried":[56],"out.":[57],"The":[58,99],"study":[59],"findings":[60],"established":[61],"accuracy":[64],"speed":[66],"response":[68],"ensuring":[69],"continuous":[71],"process":[72],"measurements":[74],"real":[76],"time.":[77],"A":[78],"new":[79,110],"model":[81],"flowmeter":[84],"developed":[87],"analytical":[89],"expressions":[90],"calculation":[92],"its":[94],"basic":[95],"obtained.":[98],"set":[103],"methods":[106],"creation":[108],"flowmeters":[111],"designs":[112],"allow":[113],"measuring":[114],"flow":[116],"biofuels":[118],"fully":[121],"automated":[122],"way,":[123],"with":[124],"high":[125],"precision":[126],"speed.":[128]},"counts_by_year":[{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":1},{"year":2018,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}