{"id":"https://openalex.org/W1619565717","doi":"https://doi.org/10.1109/coase.2015.7294221","title":"Automated performance tracking for heat exchangers in HVAC","display_name":"Automated performance tracking for heat exchangers in HVAC","publication_year":2015,"publication_date":"2015-08-01","ids":{"openalex":"https://openalex.org/W1619565717","doi":"https://doi.org/10.1109/coase.2015.7294221","mag":"1619565717"},"language":"en","primary_location":{"id":"doi:10.1109/coase.2015.7294221","is_oa":false,"landing_page_url":"https://doi.org/10.1109/coase.2015.7294221","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE International Conference on Automation Science and Engineering (CASE)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5111239404","display_name":"P. Wang","orcid":null},"institutions":[{"id":"https://openalex.org/I58956616","display_name":"Case Western Reserve University","ror":"https://ror.org/051fd9666","country_code":"US","type":"education","lineage":["https://openalex.org/I58956616"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"P. Wang","raw_affiliation_strings":["Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, OH, USA","Department of Mechanical & Aerospace Engineering, Case Western Reserve University, Cleveland, OH 44106 USA"],"affiliations":[{"raw_affiliation_string":"Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, OH, USA","institution_ids":["https://openalex.org/I58956616"]},{"raw_affiliation_string":"Department of Mechanical & Aerospace Engineering, Case Western Reserve University, Cleveland, OH 44106 USA","institution_ids":["https://openalex.org/I58956616"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5059262797","display_name":"Xu Tang","orcid":"https://orcid.org/0000-0003-1375-0778"},"institutions":[{"id":"https://openalex.org/I58956616","display_name":"Case Western Reserve University","ror":"https://ror.org/051fd9666","country_code":"US","type":"education","lineage":["https://openalex.org/I58956616"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"X. Tang","raw_affiliation_strings":["Department of Mechanical and Aerospace Engineering, Case Western Reserve University","Dept of Mechanical and Aerospace Engineering, Case Western Reserve University"],"affiliations":[{"raw_affiliation_string":"Department of Mechanical and Aerospace Engineering, Case Western Reserve University","institution_ids":["https://openalex.org/I58956616"]},{"raw_affiliation_string":"Dept of Mechanical and Aerospace Engineering, Case Western Reserve University","institution_ids":["https://openalex.org/I58956616"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5060566070","display_name":"Robert X. Gao","orcid":"https://orcid.org/0000-0003-3595-3728"},"institutions":[{"id":"https://openalex.org/I58956616","display_name":"Case Western Reserve University","ror":"https://ror.org/051fd9666","country_code":"US","type":"education","lineage":["https://openalex.org/I58956616"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"R. Gao","raw_affiliation_strings":["Engineering and the department, Case Western Reserve University","Dept of Mechanical and Aerospace Engineering, Case Western Reserve University"],"affiliations":[{"raw_affiliation_string":"Engineering and the department, Case Western Reserve University","institution_ids":["https://openalex.org/I58956616"]},{"raw_affiliation_string":"Dept of Mechanical and Aerospace Engineering, Case Western Reserve University","institution_ids":["https://openalex.org/I58956616"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5111239404"],"corresponding_institution_ids":["https://openalex.org/I58956616"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.04198095,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"32","issue":null,"first_page":"949","last_page":"954"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10534","display_name":"Structural Health Monitoring Techniques","score":0.9980999827384949,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10928","display_name":"Probabilistic and Robust Engineering Design","score":0.9887999892234802,"subfield":{"id":"https://openalex.org/subfields/1804","display_name":"Statistics, Probability and Uncertainty"},"field":{"id":"https://openalex.org/fields/18","display_name":"Decision Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.7885785698890686},{"id":"https://openalex.org/keywords/particle-filter","display_name":"Particle filter","score":0.7230591773986816},{"id":"https://openalex.org/keywords/transient","display_name":"Transient (computer programming)","score":0.6472949981689453},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.5698014497756958},{"id":"https://openalex.org/keywords/kalman-filter","display_name":"Kalman filter","score":0.5618006587028503},{"id":"https://openalex.org/keywords/tracking","display_name":"Tracking (education)","score":0.5016212463378906},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.49306604266166687},{"id":"https://openalex.org/keywords/filter","display_name":"Filter (signal processing)","score":0.4773987829685211},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.4607376456260681},{"id":"https://openalex.org/keywords/extended-kalman-filter","display_name":"Extended Kalman filter","score":0.4594472646713257},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.4319513142108917},{"id":"https://openalex.org/keywords/tracking-system","display_name":"Tracking system","score":0.41931191086769104},{"id":"https://openalex.org/keywords/heat-exchanger","display_name":"Heat exchanger","score":0.4101673662662506},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3832296133041382},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.3223709762096405},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.3140140175819397},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.17856958508491516}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.7885785698890686},{"id":"https://openalex.org/C52421305","wikidata":"https://www.wikidata.org/wiki/Q1151499","display_name":"Particle filter","level":3,"score":0.7230591773986816},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.6472949981689453},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5698014497756958},{"id":"https://openalex.org/C157286648","wikidata":"https://www.wikidata.org/wiki/Q846780","display_name":"Kalman filter","level":2,"score":0.5618006587028503},{"id":"https://openalex.org/C2775936607","wikidata":"https://www.wikidata.org/wiki/Q466845","display_name":"Tracking (education)","level":2,"score":0.5016212463378906},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.49306604266166687},{"id":"https://openalex.org/C106131492","wikidata":"https://www.wikidata.org/wiki/Q3072260","display_name":"Filter (signal processing)","level":2,"score":0.4773987829685211},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.4607376456260681},{"id":"https://openalex.org/C206833254","wikidata":"https://www.wikidata.org/wiki/Q5421817","display_name":"Extended Kalman filter","level":3,"score":0.4594472646713257},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.4319513142108917},{"id":"https://openalex.org/C154586513","wikidata":"https://www.wikidata.org/wiki/Q4420972","display_name":"Tracking system","level":3,"score":0.41931191086769104},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.4101673662662506},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3832296133041382},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.3223709762096405},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.3140140175819397},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.17856958508491516},{"id":"https://openalex.org/C15744967","wikidata":"https://www.wikidata.org/wiki/Q9418","display_name":"Psychology","level":0,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C19417346","wikidata":"https://www.wikidata.org/wiki/Q7922","display_name":"Pedagogy","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/coase.2015.7294221","is_oa":false,"landing_page_url":"https://doi.org/10.1109/coase.2015.7294221","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE International Conference on Automation Science and Engineering (CASE)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320327604","display_name":"Akershus Universitetssykehus","ror":"https://ror.org/0331wat71"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":17,"referenced_works":["https://openalex.org/W1531532259","https://openalex.org/W1968669537","https://openalex.org/W2001409570","https://openalex.org/W2022160905","https://openalex.org/W2043779128","https://openalex.org/W2063421200","https://openalex.org/W2083658684","https://openalex.org/W2083899556","https://openalex.org/W2096947102","https://openalex.org/W2103559027","https://openalex.org/W2106544870","https://openalex.org/W2111787305","https://openalex.org/W2120841219","https://openalex.org/W2124885947","https://openalex.org/W2160337655","https://openalex.org/W4249919990","https://openalex.org/W6676780147"],"related_works":["https://openalex.org/W2112866972","https://openalex.org/W4240233711","https://openalex.org/W2900606913","https://openalex.org/W4320003279","https://openalex.org/W2326910963","https://openalex.org/W3046823714","https://openalex.org/W2348218441","https://openalex.org/W3021806226","https://openalex.org/W1585960250","https://openalex.org/W2341297234"],"abstract_inverted_index":{"System":[0],"performance":[1,235],"tracking":[2,87,236],"is":[3,18,127,173,226,267],"critical":[4],"to":[5,53,83,141,165,184,269],"state":[6,58,86,187],"identification,":[7],"fault":[8,232,286],"detection":[9,233,287],"and":[10,36,75,104,158,189,203,228,234,244,273,288],"subsequent":[11],"remaining":[12],"useful":[13],"life":[14],"(RUL)":[15],"prediction.":[16],"It":[17],"not":[19],"uncommon":[20],"that":[21,61,178],"dynamic":[22],"systems":[23],"degrade":[24],"gradually":[25],"in":[26,91,129,175,241,285,291],"a":[27,116,166,238,259],"non-linear":[28,84],"manner,":[29],"occasionally":[30],"accompanied":[31],"with":[32,109,122,196],"abrupt":[33,89,142],"faults,":[34,90],"before":[35],"after":[37],"which":[38,92,172],"the":[39,69,101,107,136,149,155,159,186,191,208,214,221,251,256,264,280],"degradation":[40,108,206,289],"rates":[41],"vary.":[42],"In":[43],"addition,":[44],"uncertainty":[45,65,215],"coming":[46],"from":[47,220],"sensor":[48],"measurements":[49],"poses":[50],"more":[51],"challenges":[52],"solving":[54],"this":[55,130,176],"problem.":[56],"Existing":[57],"estimation":[59,290],"techniques":[60],"are":[62,144,162],"eligible":[63],"for":[64,230,263],"evaluation,":[66],"such":[67,249],"as":[68,211,213,250],"extended":[70],"or":[71],"unscented":[72],"Kalman":[73],"filter":[74,77,120,126,157,170],"particle":[76,125,169],"(PF),":[78],"can":[79,179,217],"only":[80],"be":[81,218],"applied":[82],"system":[85,102,138,209],"excluding":[88],"case":[93],"they":[94],"cannot:":[95],"1)":[96],"detect":[97],"transient":[98,133,201],"changes":[99,134,202],"of":[100,135,154,207,282],"states;":[103],"2)":[105],"track":[106,185],"varying":[110],"rate.":[111],"To":[112,254],"address":[113],"these":[114],"challenges,":[115],"total":[117],"variation":[118,188],"(TV)":[119],"synthesized":[121],"an":[123],"advanced":[124],"developed":[128,257],"paper.":[131],"The":[132,152,199,223,276],"noisy":[137,160],"states":[139,161],"due":[140],"faults":[143],"first":[145],"filtered":[146],"out":[147],"by":[148],"TV":[150,156],"filter.":[151],"outputs":[153],"then":[163],"routed":[164],"local":[167],"search":[168],"(LSPF),":[171],"proposed":[174,224,283],"paper":[177],"dynamically":[180],"accommodate":[181],"its":[182],"resampling":[183],"combat":[190],"sample":[192],"impoverishment":[193],"problem":[194],"associated":[195],"conventional":[197],"PFs.":[198],"corrected":[200],"estimated":[204],"gradual":[205],"states,":[210],"well":[212],"quantification":[216],"obtained":[219],"LSPF.":[222],"approach":[225],"presented":[227],"demonstrated":[229],"automatic":[231],"at":[237],"component":[239],"level":[240],"heating,":[242],"ventilation,":[243],"air":[245],"conditioning":[246],"(HVAC)":[247],"systems,":[248],"heat":[252,265,292],"exchanger.":[253,293],"evaluate":[255],"method,":[258],"finite":[260],"element":[261],"model":[262],"exchanger":[266],"established":[268],"simulate":[270],"both":[271],"normal":[272],"faulty":[274],"cases.":[275],"simulation":[277],"results":[278],"exhibit":[279],"effectiveness":[281],"method":[284]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}