{"id":"https://openalex.org/W2073347537","doi":"https://doi.org/10.1109/coase.2013.6653942","title":"Real time electricity demand response for sustainable manufacturing systems considering throughput bottleneck detection","display_name":"Real time electricity demand response for sustainable manufacturing systems considering throughput bottleneck detection","publication_year":2013,"publication_date":"2013-08-01","ids":{"openalex":"https://openalex.org/W2073347537","doi":"https://doi.org/10.1109/coase.2013.6653942","mag":"2073347537"},"language":"en","primary_location":{"id":"doi:10.1109/coase.2013.6653942","is_oa":false,"landing_page_url":"https://doi.org/10.1109/coase.2013.6653942","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 IEEE International Conference on Automation Science and Engineering (CASE)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5103102661","display_name":"Zhichao Zhou","orcid":"https://orcid.org/0000-0002-7775-0999"},"institutions":[{"id":"https://openalex.org/I39422238","display_name":"University of Illinois Chicago","ror":"https://ror.org/02mpq6x41","country_code":"US","type":"education","lineage":["https://openalex.org/I39422238"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Zhichao Zhou","raw_affiliation_strings":["Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, IL, USA","Dept. of Mech. & Ind. Eng., Univ. of Illinois at Chicago, Chicago, IL, USA"],"affiliations":[{"raw_affiliation_string":"Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, IL, USA","institution_ids":["https://openalex.org/I39422238"]},{"raw_affiliation_string":"Dept. of Mech. & Ind. Eng., Univ. of Illinois at Chicago, Chicago, IL, USA","institution_ids":["https://openalex.org/I39422238"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100412821","display_name":"Lin Li","orcid":"https://orcid.org/0000-0001-8879-8704"},"institutions":[{"id":"https://openalex.org/I39422238","display_name":"University of Illinois Chicago","ror":"https://ror.org/02mpq6x41","country_code":"US","type":"education","lineage":["https://openalex.org/I39422238"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Lin Li","raw_affiliation_strings":["Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, IL, USA","Dept. of Mech. & Ind. Eng., Univ. of Illinois at Chicago, Chicago, IL, USA"],"affiliations":[{"raw_affiliation_string":"Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, IL, USA","institution_ids":["https://openalex.org/I39422238"]},{"raw_affiliation_string":"Dept. of Mech. & Ind. Eng., Univ. of Illinois at Chicago, Chicago, IL, USA","institution_ids":["https://openalex.org/I39422238"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5103102661"],"corresponding_institution_ids":["https://openalex.org/I39422238"],"apc_list":null,"apc_paid":null,"fwci":1.1823,"has_fulltext":false,"cited_by_count":15,"citation_normalized_percentile":{"value":0.81666045,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"640","last_page":"644"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11954","display_name":"Energy Efficiency and Management","score":0.9901000261306763,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10424","display_name":"Electric Power System Optimization","score":0.9866999983787537,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/bottleneck","display_name":"Bottleneck","score":0.8221503496170044},{"id":"https://openalex.org/keywords/demand-response","display_name":"Demand response","score":0.7777416706085205},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.617719829082489},{"id":"https://openalex.org/keywords/scheduling","display_name":"Scheduling (production processes)","score":0.5669574737548828},{"id":"https://openalex.org/keywords/throughput","display_name":"Throughput","score":0.5623248219490051},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5576683878898621},{"id":"https://openalex.org/keywords/peak-demand","display_name":"Peak demand","score":0.4473079741001129},{"id":"https://openalex.org/keywords/response-time","display_name":"Response time","score":0.41828426718711853},{"id":"https://openalex.org/keywords/environmental-economics","display_name":"Environmental economics","score":0.4036632776260376},{"id":"https://openalex.org/keywords/economics","display_name":"Economics","score":0.2309107780456543},{"id":"https://openalex.org/keywords/operations-management","display_name":"Operations management","score":0.18789780139923096},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.17738187313079834}],"concepts":[{"id":"https://openalex.org/C2780513914","wikidata":"https://www.wikidata.org/wiki/Q18210350","display_name":"Bottleneck","level":2,"score":0.8221503496170044},{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.7777416706085205},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.617719829082489},{"id":"https://openalex.org/C206729178","wikidata":"https://www.wikidata.org/wiki/Q2271896","display_name":"Scheduling (production processes)","level":2,"score":0.5669574737548828},{"id":"https://openalex.org/C157764524","wikidata":"https://www.wikidata.org/wiki/Q1383412","display_name":"Throughput","level":3,"score":0.5623248219490051},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5576683878898621},{"id":"https://openalex.org/C147940328","wikidata":"https://www.wikidata.org/wiki/Q3393666","display_name":"Peak demand","level":3,"score":0.4473079741001129},{"id":"https://openalex.org/C19012869","wikidata":"https://www.wikidata.org/wiki/Q578372","display_name":"Response time","level":2,"score":0.41828426718711853},{"id":"https://openalex.org/C134560507","wikidata":"https://www.wikidata.org/wiki/Q753291","display_name":"Environmental economics","level":1,"score":0.4036632776260376},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.2309107780456543},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.18789780139923096},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.17738187313079834},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.0},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.0},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.0},{"id":"https://openalex.org/C121684516","wikidata":"https://www.wikidata.org/wiki/Q7600677","display_name":"Computer graphics (images)","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/coase.2013.6653942","is_oa":false,"landing_page_url":"https://doi.org/10.1109/coase.2013.6653942","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 IEEE International Conference on Automation Science and Engineering (CASE)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","score":0.6700000166893005,"id":"https://metadata.un.org/sdg/9"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":27,"referenced_works":["https://openalex.org/W588098693","https://openalex.org/W1548414273","https://openalex.org/W1985329954","https://openalex.org/W1993728659","https://openalex.org/W1997898472","https://openalex.org/W2021589634","https://openalex.org/W2028105921","https://openalex.org/W2038872716","https://openalex.org/W2045016194","https://openalex.org/W2071712261","https://openalex.org/W2076498178","https://openalex.org/W2079918352","https://openalex.org/W2088693678","https://openalex.org/W2103120446","https://openalex.org/W2107226462","https://openalex.org/W2115700971","https://openalex.org/W2131512356","https://openalex.org/W2132011253","https://openalex.org/W2133048964","https://openalex.org/W2150660316","https://openalex.org/W2156368412","https://openalex.org/W2164989262","https://openalex.org/W4205956952","https://openalex.org/W4237934016","https://openalex.org/W4239712672","https://openalex.org/W6633080946","https://openalex.org/W6682333414"],"related_works":["https://openalex.org/W2135248929","https://openalex.org/W2092690310","https://openalex.org/W330130819","https://openalex.org/W2794767707","https://openalex.org/W2798440551","https://openalex.org/W3190662310","https://openalex.org/W4225930592","https://openalex.org/W2052188148","https://openalex.org/W3003695187","https://openalex.org/W2555175041"],"abstract_inverted_index":{"Due":[0],"to":[1,19,39,66,90],"the":[2,9,14,23,28,31,55,82,97,111,134,148,158],"growth":[3],"of":[4,34,96,113,153],"economy,":[5],"electricity":[6,56,98,107],"demands":[7,12],"especially":[8],"peak":[10,59,159],"power":[11,155],"in":[13,22,84],"United":[15],"State":[16],"are":[17],"expected":[18],"increase":[20],"significantly":[21],"next":[24],"few":[25],"decades.":[26],"Since":[27],"infrastructure":[29],"for":[30,100,128],"new":[32],"capacity":[33],"generation,":[35],"transmission,":[36],"and":[37,70,78,88,94,151],"distribution":[38],"satisfy":[40],"this":[41,119],"increasing":[42],"demand":[43,48,57,99,108,131,156],"is":[44,64,116,137],"highly":[45],"capital":[46],"intensive,":[47],"response,":[49],"concerning":[50],"about":[51,104],"shifting":[52],"or":[53],"curtailing":[54],"during":[58,157],"periods":[60],"with":[61,81],"high":[62],"cost,":[63],"thought":[65],"be":[67],"a":[68,121],"critical":[69],"inexpensive":[71],"load":[72],"management":[73],"technique":[74],"by":[75],"both":[76],"academia":[77],"industry.":[79],"Compared":[80],"studies":[83,142],"long-term":[85],"production":[86,135],"scheduling":[87],"planning":[89],"smooth":[91],"out":[92],"peaks":[93],"valleys":[95],"manufacturing":[101],"systems,":[102],"research":[103],"real":[105,129],"time":[106,130],"response":[109,132],"under":[110,133],"constraints":[112],"system":[114,165],"throughput":[115,125],"rare.":[117],"In":[118],"paper,":[120],"heuristic":[122],"method":[123],"considering":[124],"bottleneck":[126],"detection":[127],"constraint":[136],"introduced.":[138],"The":[139],"numerical":[140],"case":[141],"yield":[143],"promising":[144],"results":[145],"which":[146],"indicate":[147],"great":[149],"potential":[150],"feasibility":[152],"reducing":[154],"period":[160],"without":[161],"negative":[162],"impact":[163],"on":[164],"throughput.":[166]},"counts_by_year":[{"year":2024,"cited_by_count":2},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":2},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":2},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":3},{"year":2014,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
