{"id":"https://openalex.org/W2481677962","doi":"https://doi.org/10.1109/civemsa.2016.7524319","title":"Secured and energy efficient architecture for sensor networks","display_name":"Secured and energy efficient architecture for sensor networks","publication_year":2016,"publication_date":"2016-06-01","ids":{"openalex":"https://openalex.org/W2481677962","doi":"https://doi.org/10.1109/civemsa.2016.7524319","mag":"2481677962"},"language":"en","primary_location":{"id":"doi:10.1109/civemsa.2016.7524319","is_oa":false,"landing_page_url":"https://doi.org/10.1109/civemsa.2016.7524319","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 IEEE International Conference on Computational Intelligence and Virtual Environments for Measurement Systems and Applications (CIVEMSA)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5029208671","display_name":"Jetendra Joshi","orcid":null},"institutions":[{"id":"https://openalex.org/I4210123960","display_name":"NIIT University","ror":"https://ror.org/02x35ep52","country_code":"IN","type":"education","lineage":["https://openalex.org/I4210123960"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Jetendra Joshi","raw_affiliation_strings":["Department of Electronics and Communication, NIIT University, Rajasthan, India"],"affiliations":[{"raw_affiliation_string":"Department of Electronics and Communication, NIIT University, Rajasthan, India","institution_ids":["https://openalex.org/I4210123960"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5090556031","display_name":"Amrit Bagga","orcid":null},"institutions":[{"id":"https://openalex.org/I4210123960","display_name":"NIIT University","ror":"https://ror.org/02x35ep52","country_code":"IN","type":"education","lineage":["https://openalex.org/I4210123960"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Amrit Bagga","raw_affiliation_strings":["Department of Electronics and Communication, NIIT University, Rajasthan, India"],"affiliations":[{"raw_affiliation_string":"Department of Electronics and Communication, NIIT University, Rajasthan, India","institution_ids":["https://openalex.org/I4210123960"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5089234530","display_name":"Abhinandan Bhargava","orcid":null},"institutions":[{"id":"https://openalex.org/I4210123960","display_name":"NIIT University","ror":"https://ror.org/02x35ep52","country_code":"IN","type":"education","lineage":["https://openalex.org/I4210123960"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Abhinandan Bhargava","raw_affiliation_strings":["Department of Electronics and Communication, NIIT University, Rajasthan, India"],"affiliations":[{"raw_affiliation_string":"Department of Electronics and Communication, NIIT University, Rajasthan, India","institution_ids":["https://openalex.org/I4210123960"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5091813504","display_name":"Abhinav Goel","orcid":"https://orcid.org/0000-0003-1827-1389"},"institutions":[{"id":"https://openalex.org/I4210123960","display_name":"NIIT University","ror":"https://ror.org/02x35ep52","country_code":"IN","type":"education","lineage":["https://openalex.org/I4210123960"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Abhinav Goel","raw_affiliation_strings":["Department of Electronics and Communication, NIIT University, Rajasthan, India"],"affiliations":[{"raw_affiliation_string":"Department of Electronics and Communication, NIIT University, Rajasthan, India","institution_ids":["https://openalex.org/I4210123960"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5084725774","display_name":"Divya Sara Kurian","orcid":null},"institutions":[{"id":"https://openalex.org/I4210123960","display_name":"NIIT University","ror":"https://ror.org/02x35ep52","country_code":"IN","type":"education","lineage":["https://openalex.org/I4210123960"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Divya Sara Kurian","raw_affiliation_strings":["Department of Electronics and Communication, NIIT University, Rajasthan, India"],"affiliations":[{"raw_affiliation_string":"Department of Electronics and Communication, NIIT University, Rajasthan, India","institution_ids":["https://openalex.org/I4210123960"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5028613907","display_name":"Urijit Kurulkar","orcid":null},"institutions":[{"id":"https://openalex.org/I4210123960","display_name":"NIIT University","ror":"https://ror.org/02x35ep52","country_code":"IN","type":"education","lineage":["https://openalex.org/I4210123960"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Urijit Kurulkar","raw_affiliation_strings":["Department of Electronics and Communication, NIIT University, Rajasthan, India"],"affiliations":[{"raw_affiliation_string":"Department of Electronics and Communication, NIIT University, Rajasthan, India","institution_ids":["https://openalex.org/I4210123960"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":["https://openalex.org/A5029208671"],"corresponding_institution_ids":["https://openalex.org/I4210123960"],"apc_list":null,"apc_paid":null,"fwci":0.8686,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.76978863,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":96},"biblio":{"volume":"501","issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10080","display_name":"Energy Efficient Wireless Sensor Networks","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10080","display_name":"Energy Efficient Wireless Sensor Networks","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11498","display_name":"Security in Wireless Sensor Networks","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10246","display_name":"Mobile Ad Hoc Networks","score":0.9939000010490417,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/wireless-sensor-network","display_name":"Wireless sensor network","score":0.8556922674179077},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7533004283905029},{"id":"https://openalex.org/keywords/key-distribution-in-wireless-sensor-networks","display_name":"Key distribution in wireless sensor networks","score":0.7193530201911926},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.6620688438415527},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.5625142455101013},{"id":"https://openalex.org/keywords/redundancy","display_name":"Redundancy (engineering)","score":0.5458533763885498},{"id":"https://openalex.org/keywords/mobile-wireless-sensor-network","display_name":"Mobile wireless sensor network","score":0.5393704175949097},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.4699796736240387},{"id":"https://openalex.org/keywords/network-topology","display_name":"Network topology","score":0.46002334356307983},{"id":"https://openalex.org/keywords/sensor-node","display_name":"Sensor node","score":0.45762357115745544},{"id":"https://openalex.org/keywords/base-station","display_name":"Base station","score":0.4445292055606842},{"id":"https://openalex.org/keywords/data-transmission","display_name":"Data transmission","score":0.41447362303733826},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.3901531398296356},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.33325228095054626},{"id":"https://openalex.org/keywords/wireless-network","display_name":"Wireless network","score":0.3053545653820038},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.14191952347755432},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.0987367331981659}],"concepts":[{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.8556922674179077},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7533004283905029},{"id":"https://openalex.org/C41971633","wikidata":"https://www.wikidata.org/wiki/Q6398155","display_name":"Key distribution in wireless sensor networks","level":4,"score":0.7193530201911926},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.6620688438415527},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.5625142455101013},{"id":"https://openalex.org/C152124472","wikidata":"https://www.wikidata.org/wiki/Q1204361","display_name":"Redundancy (engineering)","level":2,"score":0.5458533763885498},{"id":"https://openalex.org/C7091991","wikidata":"https://www.wikidata.org/wiki/Q17149548","display_name":"Mobile wireless sensor network","level":5,"score":0.5393704175949097},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.4699796736240387},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.46002334356307983},{"id":"https://openalex.org/C111185680","wikidata":"https://www.wikidata.org/wiki/Q3866206","display_name":"Sensor node","level":5,"score":0.45762357115745544},{"id":"https://openalex.org/C68649174","wikidata":"https://www.wikidata.org/wiki/Q1379116","display_name":"Base station","level":2,"score":0.4445292055606842},{"id":"https://openalex.org/C557945733","wikidata":"https://www.wikidata.org/wiki/Q389772","display_name":"Data transmission","level":2,"score":0.41447362303733826},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.3901531398296356},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.33325228095054626},{"id":"https://openalex.org/C108037233","wikidata":"https://www.wikidata.org/wiki/Q11375","display_name":"Wireless network","level":3,"score":0.3053545653820038},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.14191952347755432},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.0987367331981659},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/civemsa.2016.7524319","is_oa":false,"landing_page_url":"https://doi.org/10.1109/civemsa.2016.7524319","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 IEEE International Conference on Computational Intelligence and Virtual Environments for Measurement Systems and Applications (CIVEMSA)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8999999761581421}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":26,"referenced_works":["https://openalex.org/W300241161","https://openalex.org/W1485954968","https://openalex.org/W1998410860","https://openalex.org/W2023926423","https://openalex.org/W2038420319","https://openalex.org/W2080765376","https://openalex.org/W2088087163","https://openalex.org/W2098789505","https://openalex.org/W2104846640","https://openalex.org/W2123033018","https://openalex.org/W2126644064","https://openalex.org/W2132624333","https://openalex.org/W2135819514","https://openalex.org/W2136399700","https://openalex.org/W2140820957","https://openalex.org/W2142957722","https://openalex.org/W2148922257","https://openalex.org/W2150794496","https://openalex.org/W2169278763","https://openalex.org/W2186148010","https://openalex.org/W2563698904","https://openalex.org/W2803159876","https://openalex.org/W3124339913","https://openalex.org/W4285719527","https://openalex.org/W6686296695","https://openalex.org/W6751211686"],"related_works":["https://openalex.org/W2148549110","https://openalex.org/W2540218377","https://openalex.org/W1657620843","https://openalex.org/W2999657022","https://openalex.org/W1977342959","https://openalex.org/W2053773563","https://openalex.org/W1996270948","https://openalex.org/W2394468541","https://openalex.org/W3148968234","https://openalex.org/W4240510232"],"abstract_inverted_index":{"Wireless":[0,26,74],"Sensor":[1,27,75],"Network":[2,28,76],"has":[3,15,20,213],"been":[4,214],"one":[5,80],"of":[6,19,36,72,81,94,142,145,170,176,223,245],"the":[7,42,49,52,66,82,90,96,106,143,162,166,203,220,243],"most":[8,119],"diversified":[9],"and":[10,14,44,115,128,135,161,168,186,197,225,240],"widely":[11],"used":[12],"area":[13],"a":[16,30,33,103,133,177,183,192,246],"vast":[17],"range":[18,71,98],"applications":[21],"in":[22,105,124,219,232],"almost":[23],"every":[24],"field.":[25],"is":[29,62,99,152],"domain":[31],"with":[32,79],"large":[34],"number":[35],"motes":[37],"that":[38,139,154,236],"collects":[39],"data":[40,50,127,199,224],"from":[41],"surrounding":[43],"after":[45,59],"processing,":[46],"it":[47,61,122,237],"transfers":[48],"to":[51,65,89,190],"sink":[53],"node":[54,58],"through":[55],"intermediate":[56],"sensor":[57,146,159,179],"which":[60,101],"finally":[63],"transmitted":[64],"base":[67],"station.":[68],"With":[69],"wide":[70],"applications,":[73],"comes":[77],"up":[78],"major":[83,184],"issues":[84,175],"i.e.":[85],"Energy":[86],"Consumption.":[87],"Due":[88],"dense":[91],"network":[92,150,180],"topology":[93,151],"WSN,":[95],"communication":[97,157],"short":[100],"incurs":[102],"redundancy":[104],"sensed":[107],"data.":[108],"To":[109,201],"reduce":[110],"this":[111],"redundancy,":[112],"Data":[113,116],"Aggregation":[114],"Fusion":[117],"are":[118,181],"effective":[120],"as":[121],"helps":[123,218],"saving":[125],"both":[126],"energy.":[129,228],"This":[130],"paper":[131],"proposes":[132],"Secure":[134],"energy":[136,205,239],"efficient":[137],"architecture":[138,163,194],"takes":[140],"account":[141],"constraints":[144],"networks.":[147],"A":[148],"hierarchical":[149],"formed":[153],"enables":[155],"end-to-end":[156],"between":[158],"nodes":[160],"also":[164,182,217,226],"supports":[165],"detection":[167],"isolation":[169],"malicious":[171],"nodes.":[172],"Moreover,":[173],"security":[174],"wireless":[178],"concern":[185],"so,":[187],"we":[188,234],"aim":[189],"design":[191],"secured":[193],"for":[195],"reliable":[196],"safe":[198],"communication.":[200],"make":[202],"system":[204],"efficient,":[206],"Low-Energy":[207],"Adaptive":[208],"Clustering":[209],"Hierarchy":[210],"(LEACH)":[211],"algorithm":[212],"used.":[215],"Algorithm":[216],"secure":[221],"transmission":[222],"conserves":[227],"By":[229],"doing":[230],"simulations":[231],"NS2":[233],"found":[235],"saves":[238],"hence":[241],"enhances":[242],"lifetime":[244],"mote.":[247]},"counts_by_year":[{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
