{"id":"https://openalex.org/W2804820628","doi":"https://doi.org/10.1109/cits.2018.8440194","title":"Proactive Energy-Efficiency: Evaluation of Duty-Cycled MAC Protocols in Wireless Sensor Networks","display_name":"Proactive Energy-Efficiency: Evaluation of Duty-Cycled MAC Protocols in Wireless Sensor Networks","publication_year":2018,"publication_date":"2018-07-01","ids":{"openalex":"https://openalex.org/W2804820628","doi":"https://doi.org/10.1109/cits.2018.8440194","mag":"2804820628"},"language":"en","primary_location":{"id":"doi:10.1109/cits.2018.8440194","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cits.2018.8440194","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 International Conference on Computer, Information and Telecommunication Systems (CITS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5036195926","display_name":"Ekereuke Udoh","orcid":"https://orcid.org/0000-0003-1655-8829"},"institutions":[{"id":"https://openalex.org/I94951947","display_name":"University of Westminster","ror":"https://ror.org/04ycpbx82","country_code":"GB","type":"education","lineage":["https://openalex.org/I94951947"]}],"countries":["GB"],"is_corresponding":true,"raw_author_name":"Ekereuke Udoh","raw_affiliation_strings":["Distributed and Intelligent Systems Res. Group, University of Westminster, London, UK"],"affiliations":[{"raw_affiliation_string":"Distributed and Intelligent Systems Res. Group, University of Westminster, London, UK","institution_ids":["https://openalex.org/I94951947"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5014890583","display_name":"Vladimir Getov","orcid":"https://orcid.org/0000-0002-5597-7682"},"institutions":[{"id":"https://openalex.org/I94951947","display_name":"University of Westminster","ror":"https://ror.org/04ycpbx82","country_code":"GB","type":"education","lineage":["https://openalex.org/I94951947"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Vladimir Getov","raw_affiliation_strings":["Distributed and Intelligent Systems Res. Group, University of Westminster, London, UK"],"affiliations":[{"raw_affiliation_string":"Distributed and Intelligent Systems Res. Group, University of Westminster, London, UK","institution_ids":["https://openalex.org/I94951947"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5036195926"],"corresponding_institution_ids":["https://openalex.org/I94951947"],"apc_list":null,"apc_paid":null,"fwci":0.7815,"has_fulltext":false,"cited_by_count":11,"citation_normalized_percentile":{"value":0.7540322,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10080","display_name":"Energy Efficient Wireless Sensor Networks","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10080","display_name":"Energy Efficient Wireless Sensor Networks","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11498","display_name":"Security in Wireless Sensor Networks","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11932","display_name":"Wireless Body Area Networks","score":0.9957000017166138,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.8114722967147827},{"id":"https://openalex.org/keywords/timeout","display_name":"Timeout","score":0.7834798097610474},{"id":"https://openalex.org/keywords/throughput","display_name":"Throughput","score":0.7204575538635254},{"id":"https://openalex.org/keywords/duty-cycle","display_name":"Duty cycle","score":0.7022305727005005},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.6984081864356995},{"id":"https://openalex.org/keywords/wireless-sensor-network","display_name":"Wireless sensor network","score":0.6946148872375488},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.6621825098991394},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.5962602496147156},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.4824824631214142},{"id":"https://openalex.org/keywords/protocol","display_name":"Protocol (science)","score":0.4386410117149353},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.39764782786369324},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.38700732588768005},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.1000765860080719},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.09824317693710327},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.080667644739151},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.06457352638244629}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.8114722967147827},{"id":"https://openalex.org/C31691690","wikidata":"https://www.wikidata.org/wiki/Q1753979","display_name":"Timeout","level":2,"score":0.7834798097610474},{"id":"https://openalex.org/C157764524","wikidata":"https://www.wikidata.org/wiki/Q1383412","display_name":"Throughput","level":3,"score":0.7204575538635254},{"id":"https://openalex.org/C199822604","wikidata":"https://www.wikidata.org/wiki/Q557120","display_name":"Duty cycle","level":3,"score":0.7022305727005005},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.6984081864356995},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.6946148872375488},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.6621825098991394},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.5962602496147156},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.4824824631214142},{"id":"https://openalex.org/C2780385302","wikidata":"https://www.wikidata.org/wiki/Q367158","display_name":"Protocol (science)","level":3,"score":0.4386410117149353},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.39764782786369324},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.38700732588768005},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.1000765860080719},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.09824317693710327},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.080667644739151},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.06457352638244629},{"id":"https://openalex.org/C204787440","wikidata":"https://www.wikidata.org/wiki/Q188504","display_name":"Alternative medicine","level":2,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C142724271","wikidata":"https://www.wikidata.org/wiki/Q7208","display_name":"Pathology","level":1,"score":0.0},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/cits.2018.8440194","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cits.2018.8440194","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 International Conference on Computer, Information and Telecommunication Systems (CITS)","raw_type":"proceedings-article"},{"id":"pmh:oai:westminsterresearch.westminster.ac.uk:q5212","is_oa":false,"landing_page_url":"https://doi.org/10.1109/CITS.2018.8440194","pdf_url":null,"source":{"id":"https://openalex.org/S4306400277","display_name":"WestminsterResearch (University of Westminster)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I94951947","host_organization_name":"University of Westminster","host_organization_lineage":["https://openalex.org/I94951947"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":"","raw_type":"conference-paper"},{"id":"pmh:oai:westminsterresearch.wmin.ac.uk:21126","is_oa":false,"landing_page_url":null,"pdf_url":null,"source":{"id":"https://openalex.org/S4306400277","display_name":"WestminsterResearch (University of Westminster)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I94951947","host_organization_name":"University of Westminster","host_organization_lineage":["https://openalex.org/I94951947"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":"","raw_type":"Conference or Workshop Item"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.9100000262260437,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320320669","display_name":"University of Westminster","ror":"https://ror.org/04ycpbx82"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":20,"referenced_works":["https://openalex.org/W231180639","https://openalex.org/W1498445751","https://openalex.org/W2006936262","https://openalex.org/W2033401964","https://openalex.org/W2058161904","https://openalex.org/W2085986472","https://openalex.org/W2088718752","https://openalex.org/W2099648914","https://openalex.org/W2101363008","https://openalex.org/W2112274222","https://openalex.org/W2126259277","https://openalex.org/W2126573700","https://openalex.org/W2142100695","https://openalex.org/W2160095256","https://openalex.org/W2335480913","https://openalex.org/W2398714481","https://openalex.org/W3099618991","https://openalex.org/W4253925510","https://openalex.org/W6629797542","https://openalex.org/W7047811524"],"related_works":["https://openalex.org/W2001619020","https://openalex.org/W2318163330","https://openalex.org/W2117749464","https://openalex.org/W4362636126","https://openalex.org/W2113451084","https://openalex.org/W2094374755","https://openalex.org/W2008788431","https://openalex.org/W2045868190","https://openalex.org/W3128248980","https://openalex.org/W4388214506"],"abstract_inverted_index":{"Duty":[0],"cycling":[1],"happens":[2],"to":[3,21,26,107],"be":[4,118],"one":[5],"of":[6,29,41,95,114],"the":[7,27,33,39,58,68,77,83,89,96,112],"major":[8],"techniques":[9],"for":[10,93],"conserving":[11],"energy":[12,34,78],"in":[13,64,91],"wireless":[14],"sensor":[15],"networks":[16],"and":[17,50,80,88],"this":[18],"research":[19],"aims":[20],"answer":[22],"questions":[23],"with":[24],"regards":[25],"effect":[28],"duty":[30,84],"cycles":[31],"on":[32],"efficiency":[35],"as":[36,38,82],"well":[37],"throughput":[40,81,121],"three":[42,60,97],"duty-cycle":[43,54],"protocols":[44,55,61,98],"-":[45],"Sensor-MAC":[46],"(SMAC),":[47],"Timeout-MAC":[48],"(TMAC)":[49],"TunableMAC.":[51],"Although":[52],"other":[53],"are":[56,62,73,99],"reviewed,":[57],"aforementioned":[59],"observed":[63],"OMNET++":[65],"simulator":[66],"via":[67],"Castalia":[69],"framework.":[70],"Graphical":[71],"results":[72,92,102],"produced":[74],"which":[75],"show":[76],"consumption":[79],"cycle":[85],"is":[86,122],"varied":[87],"variations":[90],"each":[94],"analyzed.":[100],"The":[101],"provide":[103],"insight":[104],"into":[105],"how":[106],"ensure":[108],"`proactive":[109],"energy-efficiency'":[110],"whereby":[111],"impact":[113],"denial-of-sleep":[115],"attacks":[116],"can":[117],"minimized":[119],"while":[120],"maximized.":[123]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":4},{"year":2021,"cited_by_count":4}],"updated_date":"2026-04-04T16:13:02.066488","created_date":"2025-10-10T00:00:00"}
