{"id":"https://openalex.org/W4396917947","doi":"https://doi.org/10.1109/cicc60959.2024.10529010","title":"Leveraging Micro-Bump Pitch Scaling to Accelerate Interposer Link Bandwidths for Future High-Performance Compute Applications","display_name":"Leveraging Micro-Bump Pitch Scaling to Accelerate Interposer Link Bandwidths for Future High-Performance Compute Applications","publication_year":2024,"publication_date":"2024-04-21","ids":{"openalex":"https://openalex.org/W4396917947","doi":"https://doi.org/10.1109/cicc60959.2024.10529010"},"language":"en","primary_location":{"id":"doi:10.1109/cicc60959.2024.10529010","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cicc60959.2024.10529010","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 IEEE Custom Integrated Circuits Conference (CICC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5041378837","display_name":"Walker J. Turner","orcid":"https://orcid.org/0000-0001-9230-7605"},"institutions":[{"id":"https://openalex.org/I4210127875","display_name":"Nvidia (United States)","ror":"https://ror.org/03jdj4y14","country_code":"US","type":"company","lineage":["https://openalex.org/I4210127875"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Walker J. Turner","raw_affiliation_strings":["NVIDIA,Durham,NC","NVIDIA, Durham, NC"],"affiliations":[{"raw_affiliation_string":"NVIDIA,Durham,NC","institution_ids":["https://openalex.org/I4210127875"]},{"raw_affiliation_string":"NVIDIA, Durham, NC","institution_ids":["https://openalex.org/I4210127875"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5087355604","display_name":"John W. Poulton","orcid":"https://orcid.org/0000-0002-1722-7637"},"institutions":[{"id":"https://openalex.org/I4210127875","display_name":"Nvidia (United States)","ror":"https://ror.org/03jdj4y14","country_code":"US","type":"company","lineage":["https://openalex.org/I4210127875"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"John W. Poulton","raw_affiliation_strings":["NVIDIA,Durham,NC","NVIDIA, Durham, NC"],"affiliations":[{"raw_affiliation_string":"NVIDIA,Durham,NC","institution_ids":["https://openalex.org/I4210127875"]},{"raw_affiliation_string":"NVIDIA, Durham, NC","institution_ids":["https://openalex.org/I4210127875"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5078964071","display_name":"Yoshinori Nishi","orcid":"https://orcid.org/0000-0002-7178-5816"},"institutions":[{"id":"https://openalex.org/I4210127875","display_name":"Nvidia (United States)","ror":"https://ror.org/03jdj4y14","country_code":"US","type":"company","lineage":["https://openalex.org/I4210127875"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Yoshinori Nishi","raw_affiliation_strings":["NVIDIA,Santa Clara,CA","NVIDIA, Santa Clara, CA"],"affiliations":[{"raw_affiliation_string":"NVIDIA,Santa Clara,CA","institution_ids":["https://openalex.org/I4210127875"]},{"raw_affiliation_string":"NVIDIA, Santa Clara, CA","institution_ids":["https://openalex.org/I4210127875"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100329931","display_name":"Xi Chen","orcid":"https://orcid.org/0000-0002-3135-4114"},"institutions":[{"id":"https://openalex.org/I4210127875","display_name":"Nvidia (United States)","ror":"https://ror.org/03jdj4y14","country_code":"US","type":"company","lineage":["https://openalex.org/I4210127875"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Xi Chen","raw_affiliation_strings":["NVIDIA,Santa Clara,CA","NVIDIA, Santa Clara, CA"],"affiliations":[{"raw_affiliation_string":"NVIDIA,Santa Clara,CA","institution_ids":["https://openalex.org/I4210127875"]},{"raw_affiliation_string":"NVIDIA, Santa Clara, CA","institution_ids":["https://openalex.org/I4210127875"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5042467215","display_name":"Brian Zimmer","orcid":"https://orcid.org/0000-0001-9997-3141"},"institutions":[{"id":"https://openalex.org/I4210127875","display_name":"Nvidia (United States)","ror":"https://ror.org/03jdj4y14","country_code":"US","type":"company","lineage":["https://openalex.org/I4210127875"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Brian Zimmer","raw_affiliation_strings":["NVIDIA,Santa Clara,CA","NVIDIA, Santa Clara, CA"],"affiliations":[{"raw_affiliation_string":"NVIDIA,Santa Clara,CA","institution_ids":["https://openalex.org/I4210127875"]},{"raw_affiliation_string":"NVIDIA, Santa Clara, CA","institution_ids":["https://openalex.org/I4210127875"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5035039017","display_name":"Sanquan Song","orcid":null},"institutions":[{"id":"https://openalex.org/I4210127875","display_name":"Nvidia (United States)","ror":"https://ror.org/03jdj4y14","country_code":"US","type":"company","lineage":["https://openalex.org/I4210127875"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Sanquan Song","raw_affiliation_strings":["NVIDIA,Santa Clara,CA","NVIDIA, Santa Clara, CA"],"affiliations":[{"raw_affiliation_string":"NVIDIA,Santa Clara,CA","institution_ids":["https://openalex.org/I4210127875"]},{"raw_affiliation_string":"NVIDIA, Santa Clara, CA","institution_ids":["https://openalex.org/I4210127875"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5078387936","display_name":"John Wilson","orcid":"https://orcid.org/0000-0001-8488-3020"},"institutions":[{"id":"https://openalex.org/I4210127875","display_name":"Nvidia (United States)","ror":"https://ror.org/03jdj4y14","country_code":"US","type":"company","lineage":["https://openalex.org/I4210127875"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"John M. Wilson","raw_affiliation_strings":["NVIDIA,Durham,NC","NVIDIA, Durham, NC"],"affiliations":[{"raw_affiliation_string":"NVIDIA,Durham,NC","institution_ids":["https://openalex.org/I4210127875"]},{"raw_affiliation_string":"NVIDIA, Durham, NC","institution_ids":["https://openalex.org/I4210127875"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5084342236","display_name":"William J. Dally","orcid":"https://orcid.org/0000-0003-4632-2876"},"institutions":[{"id":"https://openalex.org/I4210127875","display_name":"Nvidia (United States)","ror":"https://ror.org/03jdj4y14","country_code":"US","type":"company","lineage":["https://openalex.org/I4210127875"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"William J. Dally","raw_affiliation_strings":["NVIDIA,Santa Clara,CA","NVIDIA, Santa Clara, CA"],"affiliations":[{"raw_affiliation_string":"NVIDIA,Santa Clara,CA","institution_ids":["https://openalex.org/I4210127875"]},{"raw_affiliation_string":"NVIDIA, Santa Clara, CA","institution_ids":["https://openalex.org/I4210127875"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5069026297","display_name":"C. Thomas Gray","orcid":"https://orcid.org/0000-0002-5137-5617"},"institutions":[{"id":"https://openalex.org/I4210127875","display_name":"Nvidia (United States)","ror":"https://ror.org/03jdj4y14","country_code":"US","type":"company","lineage":["https://openalex.org/I4210127875"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"C. Thomas Gray","raw_affiliation_strings":["NVIDIA,Durham,NC","NVIDIA, Durham, NC"],"affiliations":[{"raw_affiliation_string":"NVIDIA,Durham,NC","institution_ids":["https://openalex.org/I4210127875"]},{"raw_affiliation_string":"NVIDIA, Durham, NC","institution_ids":["https://openalex.org/I4210127875"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":9,"corresponding_author_ids":["https://openalex.org/A5041378837"],"corresponding_institution_ids":["https://openalex.org/I4210127875"],"apc_list":null,"apc_paid":null,"fwci":1.1098,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.76930098,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12808","display_name":"Ferroelectric and Negative Capacitance Devices","score":0.9976000189781189,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12808","display_name":"Ferroelectric and Negative Capacitance Devices","score":0.9976000189781189,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11181","display_name":"Advanced Data Storage Technologies","score":0.9944999814033508,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10054","display_name":"Parallel Computing and Optimization Techniques","score":0.9939000010490417,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7302740812301636},{"id":"https://openalex.org/keywords/bandwidth","display_name":"Bandwidth (computing)","score":0.6744277477264404},{"id":"https://openalex.org/keywords/server","display_name":"Server","score":0.5654363036155701},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.4423142075538635},{"id":"https://openalex.org/keywords/frequency-scaling","display_name":"Frequency scaling","score":0.42983412742614746},{"id":"https://openalex.org/keywords/range","display_name":"Range (aeronautics)","score":0.42137905955314636},{"id":"https://openalex.org/keywords/scaling","display_name":"Scaling","score":0.4142632782459259},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.36692726612091064},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.32817989587783813},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.24899151921272278},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.21573835611343384},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.18316006660461426},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.14872664213180542},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.12927386164665222},{"id":"https://openalex.org/keywords/aerospace-engineering","display_name":"Aerospace engineering","score":0.10063096880912781}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7302740812301636},{"id":"https://openalex.org/C2776257435","wikidata":"https://www.wikidata.org/wiki/Q1576430","display_name":"Bandwidth (computing)","level":2,"score":0.6744277477264404},{"id":"https://openalex.org/C93996380","wikidata":"https://www.wikidata.org/wiki/Q44127","display_name":"Server","level":2,"score":0.5654363036155701},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.4423142075538635},{"id":"https://openalex.org/C157742956","wikidata":"https://www.wikidata.org/wiki/Q3237776","display_name":"Frequency scaling","level":3,"score":0.42983412742614746},{"id":"https://openalex.org/C204323151","wikidata":"https://www.wikidata.org/wiki/Q905424","display_name":"Range (aeronautics)","level":2,"score":0.42137905955314636},{"id":"https://openalex.org/C99844830","wikidata":"https://www.wikidata.org/wiki/Q102441924","display_name":"Scaling","level":2,"score":0.4142632782459259},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.36692726612091064},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.32817989587783813},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.24899151921272278},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.21573835611343384},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.18316006660461426},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.14872664213180542},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.12927386164665222},{"id":"https://openalex.org/C146978453","wikidata":"https://www.wikidata.org/wiki/Q3798668","display_name":"Aerospace engineering","level":1,"score":0.10063096880912781},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/cicc60959.2024.10529010","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cicc60959.2024.10529010","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 IEEE Custom Integrated Circuits Conference (CICC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.5299999713897705}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W3183738310","https://openalex.org/W4313886962","https://openalex.org/W4360605995","https://openalex.org/W4385192407","https://openalex.org/W4385525225"],"related_works":["https://openalex.org/W2092530219","https://openalex.org/W1967088250","https://openalex.org/W2388464034","https://openalex.org/W2533125852","https://openalex.org/W2140460949","https://openalex.org/W2105580438","https://openalex.org/W2057435755","https://openalex.org/W3121798572","https://openalex.org/W2018782216","https://openalex.org/W2054730497"],"abstract_inverted_index":{"Artificial":[0],"intelligence":[1],"(AI),":[2],"and":[3,44,82],"particularly":[4],"large":[5],"language":[6],"models,":[7],"are":[8],"rapidly":[9,88],"advancing":[10],"capabilities":[11],"within":[12],"a":[13,65],"range":[14],"of":[15,54,91,102,108],"fields,":[16],"from":[17],"personal":[18],"assistants":[19],"to":[20,23,47,64],"medical":[21],"diagnosis":[22],"weather":[24],"forecasting.":[25],"This":[26],"growth":[27],"is":[28,45,71],"supported":[29],"by":[30],"high-performance":[31],"compute":[32,93],"(HPC)":[33],"datacenters,":[34],"whose":[35],"performance":[36],"has":[37],"been":[38],"doubling":[39],"every":[40],"2.5":[41],"years":[42],"[1]":[43],"likely":[46],"accelerate":[48],"over":[49],"time":[50],"based":[51],"on":[52],"demands":[53],"future":[55],"AI":[56],"applications.":[57],"These":[58],"server-class":[59],"systems":[60],"consume":[61],"energy":[62,103],"equivalent":[63],"medium-sized":[66],"city,":[67],"where":[68],"significant":[69],"power":[70],"used":[72],"for":[73],"data":[74],"movement":[75],"between":[76],"the":[77,85,99],"various":[78],"modules,":[79],"boards,":[80],"racks,":[81],"clients":[83],"throughout":[84],"datacenter.":[86],"The":[87],"growing":[89],"needs":[90],"AI-driven":[92],"require":[94],"increasing":[95],"communication":[96],"bandwidth":[97],"with":[98],"highest":[100],"degree":[101],"efficiency":[104],"across":[105],"all":[106],"levels":[107],"system":[109],"integration.":[110]},"counts_by_year":[{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
