{"id":"https://openalex.org/W2292355410","doi":"https://doi.org/10.1109/cic.2015.7410963","title":"A novel method for automatic standardization of digital electrocardiographs","display_name":"A novel method for automatic standardization of digital electrocardiographs","publication_year":2015,"publication_date":"2015-09-01","ids":{"openalex":"https://openalex.org/W2292355410","doi":"https://doi.org/10.1109/cic.2015.7410963","mag":"2292355410"},"language":"en","primary_location":{"id":"doi:10.1109/cic.2015.7410963","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cic.2015.7410963","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 Computing in Cardiology Conference (CinC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5078822702","display_name":"Eduardo B Freitas","orcid":null},"institutions":[{"id":"https://openalex.org/I98496276","display_name":"Universidade de Mogi das Cruzes","ror":"https://ror.org/04hnrs676","country_code":"BR","type":"education","lineage":["https://openalex.org/I98496276"]}],"countries":["BR"],"is_corresponding":true,"raw_author_name":"Eduardo B Freitas","raw_affiliation_strings":["Research and Technology Center on Biomedical Engineering, University of Mogi das Cruzes, Brazil"],"affiliations":[{"raw_affiliation_string":"Research and Technology Center on Biomedical Engineering, University of Mogi das Cruzes, Brazil","institution_ids":["https://openalex.org/I98496276"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5030392815","display_name":"Jo\u00e3o Salinet","orcid":"https://orcid.org/0000-0003-2906-9397"},"institutions":[{"id":"https://openalex.org/I71715416","display_name":"Universidade Federal do ABC","ror":"https://ror.org/028kg9j04","country_code":"BR","type":"education","lineage":["https://openalex.org/I71715416"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Joao L Salinet","raw_affiliation_strings":["Engineering, Federal ABC University, Brazil"],"affiliations":[{"raw_affiliation_string":"Engineering, Federal ABC University, Brazil","institution_ids":["https://openalex.org/I71715416"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5077161386","display_name":"Tiago P. Almeida","orcid":"https://orcid.org/0000-0001-5346-6937"},"institutions":[{"id":"https://openalex.org/I153648349","display_name":"University of Leicester","ror":"https://ror.org/04h699437","country_code":"GB","type":"education","lineage":["https://openalex.org/I153648349"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Tiago P Almeida","raw_affiliation_strings":["Department of Engineering, University of Leicester, United Kingdom"],"affiliations":[{"raw_affiliation_string":"Department of Engineering, University of Leicester, United Kingdom","institution_ids":["https://openalex.org/I153648349"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5032293226","display_name":"Henrique JQ Oliveira","orcid":null},"institutions":[{"id":"https://openalex.org/I98496276","display_name":"Universidade de Mogi das Cruzes","ror":"https://ror.org/04hnrs676","country_code":"BR","type":"education","lineage":["https://openalex.org/I98496276"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Henrique JQ Oliveira","raw_affiliation_strings":["Center of Biomedical Engineering University of Mogi das Cruzes"],"affiliations":[{"raw_affiliation_string":"Center of Biomedical Engineering University of Mogi das Cruzes","institution_ids":["https://openalex.org/I98496276"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5078822702"],"corresponding_institution_ids":["https://openalex.org/I98496276"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.16999487,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"525","last_page":"528"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.995199978351593,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.995199978351593,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/standardization","display_name":"Standardization","score":0.6828430891036987},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5097941756248474},{"id":"https://openalex.org/keywords/ohm","display_name":"Ohm","score":0.50322026014328},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.4536648392677307},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.351240873336792},{"id":"https://openalex.org/keywords/computer-hardware","display_name":"Computer hardware","score":0.33172348141670227},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.21054476499557495},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.1428116261959076},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.13498377799987793}],"concepts":[{"id":"https://openalex.org/C188087704","wikidata":"https://www.wikidata.org/wiki/Q369577","display_name":"Standardization","level":2,"score":0.6828430891036987},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5097941756248474},{"id":"https://openalex.org/C32211213","wikidata":"https://www.wikidata.org/wiki/Q47083","display_name":"Ohm","level":2,"score":0.50322026014328},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.4536648392677307},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.351240873336792},{"id":"https://openalex.org/C9390403","wikidata":"https://www.wikidata.org/wiki/Q3966","display_name":"Computer hardware","level":1,"score":0.33172348141670227},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.21054476499557495},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1428116261959076},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.13498377799987793},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/cic.2015.7410963","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cic.2015.7410963","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 Computing in Cardiology Conference (CinC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320321091","display_name":"Coordena\u00e7\u00e3o de Aperfei\u00e7oamento de Pessoal de N\u00edvel Superior","ror":"https://ror.org/00x0ma614"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W1984947317","https://openalex.org/W2030981473","https://openalex.org/W2766396603","https://openalex.org/W6746137261"],"related_works":["https://openalex.org/W2378767206","https://openalex.org/W1540871478","https://openalex.org/W328308450","https://openalex.org/W282641168","https://openalex.org/W2376963063","https://openalex.org/W2066396794","https://openalex.org/W2366734808","https://openalex.org/W2003100177","https://openalex.org/W2391444248","https://openalex.org/W2390716080"],"abstract_inverted_index":{"It":[0],"is":[1,36],"crucial":[2],"to":[3,10,24,46,61,92,175],"assure":[4],"the":[5,59,68,76,81,86,93,98,109,115,127,176,197],"quality":[6],"of":[7,80],"ECG":[8],"recordings":[9],"support":[11],"correct":[12],"clinical":[13],"interpretation.":[14],"This":[15],"research":[16],"aimed":[17],"at":[18,85,97,192],"developing":[19],"an":[20],"automated":[21],"standardization":[22],"method":[23],"gauge":[25,33],"digital":[26,39],"electrocardiography":[27],"(EC)":[28],"devices.":[29],"The":[30,65,142],"proposed":[31],"microprocessed":[32],"equipment":[34,105],"(MGE)":[35],"divided":[37],"into":[38],"and":[40,43,123,131,156,186],"analogic":[41],"circuits,":[42],"embedded":[44,57],"software":[45],"control":[47],"them.":[48],"Conditioned":[49],"reference":[50],"signals":[51,185],"(CRS)":[52],"from":[53,67],"Physionet":[54],"Bank":[55],"were":[56,133,167],"in":[58,108,147],"MGE":[60,69,82,110,128],"simulate":[62],"cardiac":[63],"activity.":[64],"outputs":[66],"(or":[70],"EC)":[71],"are":[72,83,90],"then":[73],"compared":[74],"with":[75,114],"CRS.":[77],"All":[78,164],"circuits":[79],"gauged":[84],"self-check":[87],"mode.":[88,101],"CRS":[89,187],"sent":[91],"EC":[94,99,104,184,198],"when":[95],"set":[96],"check":[100],"A":[102],"commercial":[103],"was":[106],"used":[107],"validation":[111],"(IEC60601-2-51:2005),":[112],"assessed":[113],"statistical":[116],"R":[117],"<sup":[118,136],"xmlns:mml=\"http://www.w3.org/1998/Math/MathML\"":[119,137],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">2</sup>":[120,138],"correlation":[121],"analysis":[122],"Kolmogorov-Smirnov":[124],"(KS).":[125],"At":[126],"self-test,":[129],"temperature":[130],"humidity":[132],"changed":[134],"(R":[135],"\u22650.99":[139],"as":[140],"designed).":[141],"KS":[143,165],"test":[144],"(P<;0.01)":[145],"resulted":[146],"D=0.012":[148],"for":[149,153,158],"amplitude":[150],"accuracy,":[151],"0.0028":[152],"timing":[154],"accuracy":[155],"0.021":[157],"signal":[159],"stability":[160],"against":[161],"noise":[162],"influence.":[163],"values":[166,173],"lower":[168],"than":[169],"their":[170],"respective":[171],"critical":[172],"according":[174],"default":[177],"standard":[178,194],"(5%).":[179],"Finally,":[180],"visual":[181],"inspection":[182],"between":[183],"on":[188],"printed":[189],"graph":[190],"paper":[191],"a":[193],"scale":[195],"certifies":[196],"reliability.":[199]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
