{"id":"https://openalex.org/W2137716965","doi":"https://doi.org/10.1109/ciasg.2011.5953338","title":"Energy management system for a renewable based microgrid with a demand side management mechanism","display_name":"Energy management system for a renewable based microgrid with a demand side management mechanism","publication_year":2011,"publication_date":"2011-04-01","ids":{"openalex":"https://openalex.org/W2137716965","doi":"https://doi.org/10.1109/ciasg.2011.5953338","mag":"2137716965"},"language":"en","primary_location":{"id":"doi:10.1109/ciasg.2011.5953338","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ciasg.2011.5953338","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 IEEE Symposium on Computational Intelligence Applications In Smart Grid (CIASG)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5035617714","display_name":"Rodrigo Palma-\u00adBehnke","orcid":"https://orcid.org/0000-0002-7508-0944"},"institutions":[{"id":"https://openalex.org/I69737025","display_name":"University of Chile","ror":"https://ror.org/047gc3g35","country_code":"CL","type":"education","lineage":["https://openalex.org/I69737025"]}],"countries":["CL"],"is_corresponding":false,"raw_author_name":"R. Palma-Behnke","raw_affiliation_strings":["Electrical Engineering Department, University of Chile, Santiago, Chile","Electrical Engineering Department, University of Chile, Santiago, Chile#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering Department, University of Chile, Santiago, Chile","institution_ids":["https://openalex.org/I69737025"]},{"raw_affiliation_string":"Electrical Engineering Department, University of Chile, Santiago, Chile#TAB#","institution_ids":["https://openalex.org/I69737025"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5066247068","display_name":"Carlos Benavides","orcid":"https://orcid.org/0000-0003-3684-2886"},"institutions":[{"id":"https://openalex.org/I69737025","display_name":"University of Chile","ror":"https://ror.org/047gc3g35","country_code":"CL","type":"education","lineage":["https://openalex.org/I69737025"]}],"countries":["CL"],"is_corresponding":false,"raw_author_name":"C. Benavides","raw_affiliation_strings":["Electrical Engineering Department, University of Chile, Santiago, Chile","Electrical Engineering Department, University of Chile, Santiago, Chile#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering Department, University of Chile, Santiago, Chile","institution_ids":["https://openalex.org/I69737025"]},{"raw_affiliation_string":"Electrical Engineering Department, University of Chile, Santiago, Chile#TAB#","institution_ids":["https://openalex.org/I69737025"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5057445147","display_name":"E. Dur\u00e1n","orcid":"https://orcid.org/0000-0001-9230-165X"},"institutions":[{"id":"https://openalex.org/I69737025","display_name":"University of Chile","ror":"https://ror.org/047gc3g35","country_code":"CL","type":"education","lineage":["https://openalex.org/I69737025"]}],"countries":["CL"],"is_corresponding":false,"raw_author_name":"E. Aranda","raw_affiliation_strings":["Electrical Engineering Department, University of Chile, Santiago, Chile","Electrical Engineering Department, University of Chile, Santiago, Chile#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering Department, University of Chile, Santiago, Chile","institution_ids":["https://openalex.org/I69737025"]},{"raw_affiliation_string":"Electrical Engineering Department, University of Chile, Santiago, Chile#TAB#","institution_ids":["https://openalex.org/I69737025"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5017591296","display_name":"Jacqueline Llanos","orcid":"https://orcid.org/0000-0002-6708-3897"},"institutions":[{"id":"https://openalex.org/I69737025","display_name":"University of Chile","ror":"https://ror.org/047gc3g35","country_code":"CL","type":"education","lineage":["https://openalex.org/I69737025"]}],"countries":["CL"],"is_corresponding":false,"raw_author_name":"J. Llanos","raw_affiliation_strings":["Electrical Engineering Department, University of Chile, Santiago, Chile","Electrical Engineering Department, University of Chile, Santiago, Chile#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering Department, University of Chile, Santiago, Chile","institution_ids":["https://openalex.org/I69737025"]},{"raw_affiliation_string":"Electrical Engineering Department, University of Chile, Santiago, Chile#TAB#","institution_ids":["https://openalex.org/I69737025"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5057542669","display_name":"Doris S\u00e1ez","orcid":"https://orcid.org/0000-0001-8029-9871"},"institutions":[{"id":"https://openalex.org/I69737025","display_name":"University of Chile","ror":"https://ror.org/047gc3g35","country_code":"CL","type":"education","lineage":["https://openalex.org/I69737025"]}],"countries":["CL"],"is_corresponding":false,"raw_author_name":"D. Saez","raw_affiliation_strings":["Electrical Engineering Department, University of Chile, Santiago, Chile","Electrical Engineering Department, University of Chile, Santiago, Chile#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering Department, University of Chile, Santiago, Chile","institution_ids":["https://openalex.org/I69737025"]},{"raw_affiliation_string":"Electrical Engineering Department, University of Chile, Santiago, Chile#TAB#","institution_ids":["https://openalex.org/I69737025"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":9.1903,"has_fulltext":false,"cited_by_count":123,"citation_normalized_percentile":{"value":0.98218441,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":95,"max":100},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"8"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11052","display_name":"Energy Load and Power Forecasting","score":0.9972000122070312,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.9113203883171082},{"id":"https://openalex.org/keywords/energy-management-system","display_name":"Energy management system","score":0.68896484375},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.6187448501586914},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.5906161665916443},{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.5684474110603333},{"id":"https://openalex.org/keywords/diesel-generator","display_name":"Diesel generator","score":0.5324617028236389},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5209887623786926},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.5145749449729919},{"id":"https://openalex.org/keywords/management-system","display_name":"Management system","score":0.46685606241226196},{"id":"https://openalex.org/keywords/load-management","display_name":"Load management","score":0.43008702993392944},{"id":"https://openalex.org/keywords/battery","display_name":"Battery (electricity)","score":0.4110450744628906},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3898080587387085},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2913471758365631},{"id":"https://openalex.org/keywords/diesel-fuel","display_name":"Diesel fuel","score":0.2361389696598053},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.2077612280845642},{"id":"https://openalex.org/keywords/operations-management","display_name":"Operations management","score":0.17265069484710693},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.17174586653709412}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.9113203883171082},{"id":"https://openalex.org/C2781260460","wikidata":"https://www.wikidata.org/wiki/Q6139999","display_name":"Energy management system","level":4,"score":0.68896484375},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.6187448501586914},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.5906161665916443},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.5684474110603333},{"id":"https://openalex.org/C2776301318","wikidata":"https://www.wikidata.org/wiki/Q963375","display_name":"Diesel generator","level":3,"score":0.5324617028236389},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5209887623786926},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.5145749449729919},{"id":"https://openalex.org/C198783460","wikidata":"https://www.wikidata.org/wiki/Q629173","display_name":"Management system","level":2,"score":0.46685606241226196},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.43008702993392944},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.4110450744628906},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3898080587387085},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2913471758365631},{"id":"https://openalex.org/C138171918","wikidata":"https://www.wikidata.org/wiki/Q38423","display_name":"Diesel fuel","level":2,"score":0.2361389696598053},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2077612280845642},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.17265069484710693},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.17174586653709412},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ciasg.2011.5953338","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ciasg.2011.5953338","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 IEEE Symposium on Computational Intelligence Applications In Smart Grid (CIASG)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.8399999737739563,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":15,"referenced_works":["https://openalex.org/W1535260033","https://openalex.org/W1962658814","https://openalex.org/W1976720562","https://openalex.org/W2036508553","https://openalex.org/W2095731600","https://openalex.org/W2097746216","https://openalex.org/W2101672261","https://openalex.org/W2128244370","https://openalex.org/W2139851820","https://openalex.org/W2143344495","https://openalex.org/W2144456054","https://openalex.org/W2149723631","https://openalex.org/W2162718310","https://openalex.org/W2915783575","https://openalex.org/W6682675615"],"related_works":["https://openalex.org/W2532566870","https://openalex.org/W4210475462","https://openalex.org/W3005622763","https://openalex.org/W2333017163","https://openalex.org/W2964937504","https://openalex.org/W2169268775","https://openalex.org/W2749199243","https://openalex.org/W4220876800","https://openalex.org/W2347673489","https://openalex.org/W2371966636"],"abstract_inverted_index":{"A":[0],"novel":[1],"energy":[2,62],"management":[3,37,63],"system":[4,64,104,135],"for":[5,17,23,30,93,129],"a":[6,24,34,47,50,53,57,80,90,94,110,115,130,137],"renewable":[7],"based":[8,32],"microgrid":[9,41],"is":[10,42,101,105],"proposed.":[11],"It":[12,78],"provides":[13],"on-line":[14],"set":[15,113,125],"points":[16,126],"each":[18],"generation":[19],"unit,":[20],"operation":[21],"modes":[22],"water":[25,58,73],"supply":[26,59],"system,":[27],"and":[28,56,74,107,127],"signals":[29],"consumers":[31],"on":[33],"demand":[35],"side":[36],"mechanism.":[38],"The":[39,61,103],"smart":[40],"composed":[43],"of":[44,85,123,133],"photovoltaic":[45],"panels,":[46],"wind":[48],"turbine,":[49],"diesel":[51],"generator,":[52],"battery":[54],"bank,":[55],"system.":[60],"(EMS)":[65],"minimizes":[66],"the":[67,72,86,120,124,134],"operational":[68],"costs":[69],"while":[70],"supplying":[71],"electric":[75,98],"load":[76],"demands.":[77],"considers":[79],"two":[81,95],"days":[82,96],"ahead":[83,97],"prediction":[84],"weather":[87],"conditions.":[88],"Also,":[89],"neural":[91],"network":[92],"consumption":[99],"forecasting":[100],"designed.":[102],"implemented":[106],"tested":[108],"using":[109],"real":[111],"data":[112],"from":[114],"reference":[116],"location.":[117],"Results":[118],"show":[119],"economic":[121],"sense":[122],"management,":[128],"practical":[131],"implementation":[132],"in":[136,140],"specific":[138],"location":[139],"Chile.":[141]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":5},{"year":2024,"cited_by_count":8},{"year":2023,"cited_by_count":7},{"year":2022,"cited_by_count":5},{"year":2021,"cited_by_count":6},{"year":2020,"cited_by_count":9},{"year":2019,"cited_by_count":7},{"year":2018,"cited_by_count":9},{"year":2017,"cited_by_count":14},{"year":2016,"cited_by_count":8},{"year":2015,"cited_by_count":10},{"year":2014,"cited_by_count":14},{"year":2013,"cited_by_count":7},{"year":2012,"cited_by_count":11}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
