{"id":"https://openalex.org/W3012110435","doi":"https://doi.org/10.1109/cdc40024.2019.9029730","title":"Steady-State Analysis of HVAC Performance using Indoor Fans in Control Design","display_name":"Steady-State Analysis of HVAC Performance using Indoor Fans in Control Design","publication_year":2019,"publication_date":"2019-12-01","ids":{"openalex":"https://openalex.org/W3012110435","doi":"https://doi.org/10.1109/cdc40024.2019.9029730","mag":"3012110435"},"language":"en","primary_location":{"id":"doi:10.1109/cdc40024.2019.9029730","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cdc40024.2019.9029730","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 IEEE 58th Conference on Decision and Control (CDC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5008030444","display_name":"Joaquin G. Ordonez","orcid":"https://orcid.org/0000-0001-7787-5831"},"institutions":[{"id":"https://openalex.org/I79238269","display_name":"Universidad de Sevilla","ror":"https://ror.org/03yxnpp24","country_code":"ES","type":"education","lineage":["https://openalex.org/I79238269"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Joaquin G. Ordonez","raw_affiliation_strings":["Department of Systems Engineering and Automation, University of Seville, Seville, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Systems Engineering and Automation, University of Seville, Seville, Spain","institution_ids":["https://openalex.org/I79238269"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5072891938","display_name":"Claus Danielson","orcid":"https://orcid.org/0000-0002-2317-3014"},"institutions":[{"id":"https://openalex.org/I4210159266","display_name":"Mitsubishi Electric (United States)","ror":"https://ror.org/053jnhe44","country_code":"US","type":"company","lineage":["https://openalex.org/I1306287861","https://openalex.org/I4210133125","https://openalex.org/I4210159266"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Claus Danielson","raw_affiliation_strings":["Control and Dynamical Systems Group, Mitsubishi Electric Research Laboratories, Cambridge, MA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Control and Dynamical Systems Group, Mitsubishi Electric Research Laboratories, Cambridge, MA, USA","institution_ids":["https://openalex.org/I4210159266"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5068334157","display_name":"Daniel Lim\u00f3n","orcid":"https://orcid.org/0000-0001-9334-7289"},"institutions":[{"id":"https://openalex.org/I79238269","display_name":"Universidad de Sevilla","ror":"https://ror.org/03yxnpp24","country_code":"ES","type":"education","lineage":["https://openalex.org/I79238269"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Daniel Limon","raw_affiliation_strings":["Department of Systems Engineering and Automation, University of Seville, Seville, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Systems Engineering and Automation, University of Seville, Seville, Spain","institution_ids":["https://openalex.org/I79238269"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5039935451","display_name":"Scott A. Bortoff","orcid":"https://orcid.org/0000-0003-0027-9075"},"institutions":[{"id":"https://openalex.org/I4210159266","display_name":"Mitsubishi Electric (United States)","ror":"https://ror.org/053jnhe44","country_code":"US","type":"company","lineage":["https://openalex.org/I1306287861","https://openalex.org/I4210133125","https://openalex.org/I4210159266"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Scott A. Bortoff","raw_affiliation_strings":["Control and Dynamical Systems Group, Mitsubishi Electric Research Laboratories, Cambridge, MA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Control and Dynamical Systems Group, Mitsubishi Electric Research Laboratories, Cambridge, MA, USA","institution_ids":["https://openalex.org/I4210159266"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5004144091","display_name":"Stefano Di Cairano","orcid":"https://orcid.org/0000-0002-2363-2807"},"institutions":[{"id":"https://openalex.org/I4210159266","display_name":"Mitsubishi Electric (United States)","ror":"https://ror.org/053jnhe44","country_code":"US","type":"company","lineage":["https://openalex.org/I1306287861","https://openalex.org/I4210133125","https://openalex.org/I4210159266"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Stefano Di Cairano","raw_affiliation_strings":["Control and Dynamical Systems Group, Mitsubishi Electric Research Laboratories, Cambridge, MA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Control and Dynamical Systems Group, Mitsubishi Electric Research Laboratories, Cambridge, MA, USA","institution_ids":["https://openalex.org/I4210159266"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.1626,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.5913037,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"2952","last_page":"2957"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.9907000064849854,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.955299973487854,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.9564348459243774},{"id":"https://openalex.org/keywords/refrigerant","display_name":"Refrigerant","score":0.6980555057525635},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.6225760579109192},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.5806195735931396},{"id":"https://openalex.org/keywords/ventilation","display_name":"Ventilation (architecture)","score":0.5229892730712891},{"id":"https://openalex.org/keywords/environmental-science","display_name":"Environmental science","score":0.4326314330101013},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4252961277961731},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.41678228974342346},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.35809457302093506},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.29899245500564575},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.1509016454219818},{"id":"https://openalex.org/keywords/heat-exchanger","display_name":"Heat exchanger","score":0.14534857869148254}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.9564348459243774},{"id":"https://openalex.org/C199499590","wikidata":"https://www.wikidata.org/wiki/Q266790","display_name":"Refrigerant","level":3,"score":0.6980555057525635},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.6225760579109192},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.5806195735931396},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.5229892730712891},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.4326314330101013},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4252961277961731},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.41678228974342346},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.35809457302093506},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.29899245500564575},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.1509016454219818},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.14534857869148254},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/cdc40024.2019.9029730","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cdc40024.2019.9029730","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 IEEE 58th Conference on Decision and Control (CDC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8999999761581421,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W1524886571","https://openalex.org/W1914493662","https://openalex.org/W1972968312","https://openalex.org/W1973944436","https://openalex.org/W2053009031","https://openalex.org/W2061457131","https://openalex.org/W2134781609","https://openalex.org/W2163121678","https://openalex.org/W2514410025","https://openalex.org/W2536620281","https://openalex.org/W2620128872","https://openalex.org/W2968437435","https://openalex.org/W6631546732"],"related_works":["https://openalex.org/W2954045475","https://openalex.org/W40004226","https://openalex.org/W4311842983","https://openalex.org/W2380630059","https://openalex.org/W2053725876","https://openalex.org/W1966382697","https://openalex.org/W2943051929","https://openalex.org/W2592269242","https://openalex.org/W2157605661","https://openalex.org/W3046823714"],"abstract_inverted_index":{"Indoor":[0],"fans":[1,60],"are":[2,36,190],"high-authority":[3],"actuators":[4],"in":[5,102,144,177],"heating,":[6],"ventilation,":[7],"and":[8,22,77,111,120,134,182,187],"air":[9],"conditioning":[10],"(HVAC)":[11],"systems":[12],"since":[13],"they":[14],"facilitate":[15],"the":[16,32,38,41,45,52,58,62,67,84,87,99,113,124,127,142,150,173,183],"transfer":[17],"of":[18,40,54,57,86,115,126,155,166],"heat":[19],"between":[20],"refrigerant":[21,28],"room":[23,104,178],"air.":[24],"In":[25],"some":[26],"variable":[27],"flow":[29],"(VRF)":[30],"systems,":[31],"indoor":[33,59,116,151,167],"fan":[34,152],"speeds":[35],"under":[37],"control":[39,47,56],"occupants,":[42],"rather":[43],"than":[44],"HVAC":[46,63,88,128],"system.":[48],"This":[49],"paper":[50],"studies":[51],"benefits":[53],"transferring":[55],"to":[61,74,90,130],"controller.":[64],"We":[65],"quantify":[66],"system":[68,89,129],"performance":[69],"using":[70],"five":[71],"metrics":[72,122,140,157],"related":[73],"occupant":[75],"comfort":[76],"power":[78,145,193],"consumption.":[79],"The":[80,118,137],"first":[81],"metric":[82],"measures":[83],"ability":[85,125],"accommodate":[91],"users":[92],"with":[93,110],"different":[94],"temperature":[95],"preferences":[96],"by":[97,148],"quantifying":[98],"largest":[100],"difference":[101,176],"requested":[103],"temperatures":[105,179],"that":[106,172],"can":[107],"be":[108],"achieved":[109],"without":[112],"aid":[114],"fans.":[117],"second":[119],"third":[121],"measure":[123,141],"reject":[131],"extreme":[132],"heating":[133,186],"cooling":[135,188],"loads.":[136],"final":[138],"two":[139],"reduction":[143],"consumption":[146,194],"obtained":[147],"manipulating":[149],"speeds.":[153],"Each":[154],"these":[156],"is":[158,180,195],"computed":[159],"via":[160],"linear":[161],"programming":[162],"for":[163],"varying":[164],"numbers":[165],"units.":[168],"Simulation":[169],"results":[170],"indicate":[171],"maximum":[174,184],"steady-state":[175],"tripled,":[181],"rejected":[185],"loads":[189],"doubled.":[191],"Furthermore,":[192],"significantly":[196],"reduced.":[197]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2020,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
