{"id":"https://openalex.org/W3011852067","doi":"https://doi.org/10.1109/cdc40024.2019.9029506","title":"Data-Driven Distributed Reactive Power Sharing in Microgrids","display_name":"Data-Driven Distributed Reactive Power Sharing in Microgrids","publication_year":2019,"publication_date":"2019-12-01","ids":{"openalex":"https://openalex.org/W3011852067","doi":"https://doi.org/10.1109/cdc40024.2019.9029506","mag":"3011852067"},"language":"en","primary_location":{"id":"doi:10.1109/cdc40024.2019.9029506","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cdc40024.2019.9029506","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 IEEE 58th Conference on Decision and Control (CDC)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"http://infoscience.epfl.ch/record/279305","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5004116579","display_name":"Seyed Sohail Madani","orcid":"https://orcid.org/0000-0002-5166-7492"},"institutions":[{"id":"https://openalex.org/I5124864","display_name":"\u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne","ror":"https://ror.org/02s376052","country_code":"CH","type":"education","lineage":["https://openalex.org/I2799323385","https://openalex.org/I5124864"]}],"countries":["CH"],"is_corresponding":false,"raw_author_name":"Seyed Sohail Madani","raw_affiliation_strings":["Laboratoire d\u2019 Automatique, \u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne, Lausanne, Switzerland","Laboratoire d' Automatique, \u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne, Lausanne, Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Laboratoire d\u2019 Automatique, \u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne, Lausanne, Switzerland","institution_ids":["https://openalex.org/I5124864"]},{"raw_affiliation_string":"Laboratoire d' Automatique, \u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne, Lausanne, Switzerland","institution_ids":["https://openalex.org/I5124864"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5003734377","display_name":"Alireza Karimi","orcid":"https://orcid.org/0000-0003-4232-3695"},"institutions":[{"id":"https://openalex.org/I5124864","display_name":"\u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne","ror":"https://ror.org/02s376052","country_code":"CH","type":"education","lineage":["https://openalex.org/I2799323385","https://openalex.org/I5124864"]}],"countries":["CH"],"is_corresponding":false,"raw_author_name":"Alireza Karimi","raw_affiliation_strings":["Laboratoire d\u2019 Automatique, \u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne, Lausanne, Switzerland","Laboratoire d' Automatique, \u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne, Lausanne, Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Laboratoire d\u2019 Automatique, \u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne, Lausanne, Switzerland","institution_ids":["https://openalex.org/I5124864"]},{"raw_affiliation_string":"Laboratoire d' Automatique, \u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne, Lausanne, Switzerland","institution_ids":["https://openalex.org/I5124864"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I5124864"],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":true,"cited_by_count":2,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"7512","last_page":"7517"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9977999925613403,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.996399998664856,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.7709208726882935},{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.7311191558837891},{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.5486252903938293},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5434253215789795},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.516846239566803},{"id":"https://openalex.org/keywords/parametric-statistics","display_name":"Parametric statistics","score":0.48862916231155396},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.4844977557659149},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.449844092130661},{"id":"https://openalex.org/keywords/voltage-optimisation","display_name":"Voltage optimisation","score":0.4253818988800049},{"id":"https://openalex.org/keywords/convex-optimization","display_name":"Convex optimization","score":0.4230555295944214},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.41816776990890503},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3815246820449829},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.3805125653743744},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.31678006052970886},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.28180941939353943},{"id":"https://openalex.org/keywords/regular-polygon","display_name":"Regular polygon","score":0.20763960480690002},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.15189507603645325},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.1459980309009552},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.1112455427646637}],"concepts":[{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.7709208726882935},{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.7311191558837891},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.5486252903938293},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5434253215789795},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.516846239566803},{"id":"https://openalex.org/C117251300","wikidata":"https://www.wikidata.org/wiki/Q1849855","display_name":"Parametric statistics","level":2,"score":0.48862916231155396},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.4844977557659149},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.449844092130661},{"id":"https://openalex.org/C46529443","wikidata":"https://www.wikidata.org/wiki/Q7940750","display_name":"Voltage optimisation","level":4,"score":0.4253818988800049},{"id":"https://openalex.org/C157972887","wikidata":"https://www.wikidata.org/wiki/Q463359","display_name":"Convex optimization","level":3,"score":0.4230555295944214},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.41816776990890503},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3815246820449829},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3805125653743744},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.31678006052970886},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.28180941939353943},{"id":"https://openalex.org/C112680207","wikidata":"https://www.wikidata.org/wiki/Q714886","display_name":"Regular polygon","level":2,"score":0.20763960480690002},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.15189507603645325},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.1459980309009552},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.1112455427646637},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/cdc40024.2019.9029506","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cdc40024.2019.9029506","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 IEEE 58th Conference on Decision and Control (CDC)","raw_type":"proceedings-article"},{"id":"pmh:oai:infoscience.epfl.ch:279305","is_oa":true,"landing_page_url":"https://infoscience.epfl.ch/handle/20.500.14299/170757","pdf_url":"http://infoscience.epfl.ch/record/279305","source":{"id":"https://openalex.org/S4306400487","display_name":"Infoscience (Ecole Polytechnique F\u00e9d\u00e9rale de Lausanne)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"conference proceedings"}],"best_oa_location":{"id":"pmh:oai:infoscience.epfl.ch:279305","is_oa":true,"landing_page_url":"https://infoscience.epfl.ch/handle/20.500.14299/170757","pdf_url":"http://infoscience.epfl.ch/record/279305","source":{"id":"https://openalex.org/S4306400487","display_name":"Infoscience (Ecole Polytechnique F\u00e9d\u00e9rale de Lausanne)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"conference proceedings"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.7900000214576721,"display_name":"Affordable and clean energy"}],"awards":[{"id":"https://openalex.org/G7687927876","display_name":"Transient Control in Distributed Energy Systems","funder_award_id":"172828","funder_id":"https://openalex.org/F4320320924","funder_display_name":"Schweizerischer Nationalfonds zur F\u00f6rderung der Wissenschaftlichen Forschung"},{"id":"https://openalex.org/G993971353","display_name":null,"funder_award_id":"200021","funder_id":"https://openalex.org/F4320320924","funder_display_name":"Schweizerischer Nationalfonds zur F\u00f6rderung der Wissenschaftlichen Forschung"}],"funders":[{"id":"https://openalex.org/F4320306076","display_name":"National Science Foundation","ror":"https://ror.org/021nxhr62"},{"id":"https://openalex.org/F4320320924","display_name":"Schweizerischer Nationalfonds zur F\u00f6rderung der Wissenschaftlichen Forschung","ror":"https://ror.org/00yjd3n13"}],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W3011852067.pdf","grobid_xml":"https://content.openalex.org/works/W3011852067.grobid-xml"},"referenced_works_count":19,"referenced_works":["https://openalex.org/W1491522387","https://openalex.org/W1969576074","https://openalex.org/W1984070343","https://openalex.org/W2017734510","https://openalex.org/W2044124002","https://openalex.org/W2067743683","https://openalex.org/W2114242884","https://openalex.org/W2157056167","https://openalex.org/W2187598045","https://openalex.org/W2262192964","https://openalex.org/W2335036212","https://openalex.org/W2342938949","https://openalex.org/W2526692468","https://openalex.org/W2545910513","https://openalex.org/W2626806643","https://openalex.org/W2733716725","https://openalex.org/W2751709234","https://openalex.org/W2796032514","https://openalex.org/W2806651159"],"related_works":["https://openalex.org/W2355150740","https://openalex.org/W1570369983","https://openalex.org/W2051053503","https://openalex.org/W3112588909","https://openalex.org/W1993958856","https://openalex.org/W4390189035","https://openalex.org/W2386029912","https://openalex.org/W2354335100","https://openalex.org/W2374445781","https://openalex.org/W2131131579"],"abstract_inverted_index":{"In":[0,29,117],"this":[1,161],"paper,":[2],"reactive":[3,32,166],"power":[4,33,42,68,79,100,167],"sharing":[5],"for":[6,38,73,132,176],"Photovoltaic":[7],"(PV)":[8],"units":[9,171],"in":[10,55,127],"islanded":[11],"microgrids":[12],"has":[13,141,163],"been":[14,44,142],"formulated":[15,45],"as":[16,111],"a":[17,74,103,147],"robust":[18],"control":[19,129],"design":[20,130],"problem":[21,86],"and":[22,40,53,108,115,135,154,178],"is":[23,87],"solved":[24],"using":[25,46],"convex":[26],"optimization":[27],"method.":[28],"addition":[30],"to":[31,99],"sharing,":[34],"the":[35,50,56,63,67,78,85,90,93,118,121,128],"disturbance":[36,174],"rejection":[37,175],"voltage":[39,177],"active":[41,179],"have":[43],"infinity-norm":[47],"constraints":[48],"on":[49],"sensitivity":[51],"functions":[52],"considered":[54,126],"design.":[57],"The":[58,82,138,157],"proposed":[59,119,139],"method":[60,140,162],"uses":[61],"only":[62],"measurement":[64],"data":[65],"of":[66,77,84,89,92,106,146],"system":[69,123],"with":[70],"no":[71],"need":[72],"parametric":[75],"model":[76],"grid":[80],"equipment.":[81],"size":[83],"independent":[88],"order":[91],"plant":[94],"which":[95],"makes":[96],"it":[97],"applicable":[98],"systems":[101],"including":[102],"high":[104],"number":[105],"buses":[107],"equipment":[109],"such":[110],"synchronous":[112,150],"generators,":[113],"batteries":[114],"inverters.":[116],"method,":[120],"communication":[122],"can":[124],"be":[125],"process":[131],"centralized,":[133],"distributed":[134],"decentralized":[136],"structures.":[137],"validated":[143],"through":[144],"simulation":[145],"microgrid":[148],"encompassing":[149],"generator,":[151],"switching":[152],"inverters":[153],"storage":[155],"system.":[156],"results":[158],"show":[159],"that":[160],"successfully":[164],"shared":[165],"among":[168],"different":[169],"PV":[170],"while":[172],"providing":[173],"power.":[180]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2022,"cited_by_count":1}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
