{"id":"https://openalex.org/W2903872726","doi":"https://doi.org/10.1109/cdc.2018.8619529","title":"Use of Model Predictive Control for Short-Term Operating Reserve Using Commercial Buildings in the United Kingdom Context","display_name":"Use of Model Predictive Control for Short-Term Operating Reserve Using Commercial Buildings in the United Kingdom Context","publication_year":2018,"publication_date":"2018-12-01","ids":{"openalex":"https://openalex.org/W2903872726","doi":"https://doi.org/10.1109/cdc.2018.8619529","mag":"2903872726"},"language":"en","primary_location":{"id":"doi:10.1109/cdc.2018.8619529","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cdc.2018.8619529","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE Conference on Decision and Control (CDC)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://research.manchester.ac.uk/en/publications/a69a8f17-1b80-4ac2-ae7d-b7c3e64dbf9a","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5068103868","display_name":"Henri Max Bittel","orcid":null},"institutions":[{"id":"https://openalex.org/I5124864","display_name":"\u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne","ror":"https://ror.org/02s376052","country_code":"CH","type":"education","lineage":["https://openalex.org/I2799323385","https://openalex.org/I5124864"]}],"countries":["CH"],"is_corresponding":false,"raw_author_name":"Henri Bittel","raw_affiliation_strings":["Automatic Laboratory, Ecole Polytechnique Federale de Lausanne, Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Automatic Laboratory, Ecole Polytechnique Federale de Lausanne, Switzerland","institution_ids":["https://openalex.org/I5124864"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5085117832","display_name":"Colin N. Jones","orcid":"https://orcid.org/0000-0001-7239-4799"},"institutions":[{"id":"https://openalex.org/I5124864","display_name":"\u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne","ror":"https://ror.org/02s376052","country_code":"CH","type":"education","lineage":["https://openalex.org/I2799323385","https://openalex.org/I5124864"]}],"countries":["CH"],"is_corresponding":false,"raw_author_name":"Colin Neil Jones","raw_affiliation_strings":["Automatic Laboratory, Ecole Polytechnique Federale de Lausanne, Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Automatic Laboratory, Ecole Polytechnique Federale de Lausanne, Switzerland","institution_ids":["https://openalex.org/I5124864"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5016113073","display_name":"Alessandra Parisio","orcid":"https://orcid.org/0000-0001-8633-1641"},"institutions":[{"id":"https://openalex.org/I28407311","display_name":"University of Manchester","ror":"https://ror.org/027m9bs27","country_code":"GB","type":"education","lineage":["https://openalex.org/I28407311"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Alessandra Parisio","raw_affiliation_strings":["School of Electrical & Electronic Engineering, University of Manchester, United Kingdom"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electrical & Electronic Engineering, University of Manchester, United Kingdom","institution_ids":["https://openalex.org/I28407311"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":8,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"7308","last_page":"7313"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.996999979019165,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":0.9890999794006348,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/flexibility","display_name":"Flexibility (engineering)","score":0.6710797548294067},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.5664399266242981},{"id":"https://openalex.org/keywords/context","display_name":"Context (archaeology)","score":0.5618901252746582},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5090402960777283},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.5084871053695679},{"id":"https://openalex.org/keywords/term","display_name":"Term (time)","score":0.48467734456062317},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.47283491492271423},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4716046452522278},{"id":"https://openalex.org/keywords/model-predictive-control","display_name":"Model predictive control","score":0.4556465744972229},{"id":"https://openalex.org/keywords/demand-response","display_name":"Demand response","score":0.4452197551727295},{"id":"https://openalex.org/keywords/reserve-requirement","display_name":"Reserve requirement","score":0.4260335862636566},{"id":"https://openalex.org/keywords/environmental-economics","display_name":"Environmental economics","score":0.3966148793697357},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.3622938394546509},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.32034584879875183},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2730898857116699},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.2426052987575531},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.18188294768333435},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.1360204815864563},{"id":"https://openalex.org/keywords/economics","display_name":"Economics","score":0.09069669246673584}],"concepts":[{"id":"https://openalex.org/C2780598303","wikidata":"https://www.wikidata.org/wiki/Q65921492","display_name":"Flexibility (engineering)","level":2,"score":0.6710797548294067},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.5664399266242981},{"id":"https://openalex.org/C2779343474","wikidata":"https://www.wikidata.org/wiki/Q3109175","display_name":"Context (archaeology)","level":2,"score":0.5618901252746582},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5090402960777283},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5084871053695679},{"id":"https://openalex.org/C61797465","wikidata":"https://www.wikidata.org/wiki/Q1188986","display_name":"Term (time)","level":2,"score":0.48467734456062317},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.47283491492271423},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4716046452522278},{"id":"https://openalex.org/C172205157","wikidata":"https://www.wikidata.org/wiki/Q1782962","display_name":"Model predictive control","level":3,"score":0.4556465744972229},{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.4452197551727295},{"id":"https://openalex.org/C150149615","wikidata":"https://www.wikidata.org/wiki/Q1058762","display_name":"Reserve requirement","level":4,"score":0.4260335862636566},{"id":"https://openalex.org/C134560507","wikidata":"https://www.wikidata.org/wiki/Q753291","display_name":"Environmental economics","level":1,"score":0.3966148793697357},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3622938394546509},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.32034584879875183},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2730898857116699},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.2426052987575531},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.18188294768333435},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1360204815864563},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.09069669246673584},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C187736073","wikidata":"https://www.wikidata.org/wiki/Q2920921","display_name":"Management","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C126285488","wikidata":"https://www.wikidata.org/wiki/Q178476","display_name":"Monetary policy","level":2,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C556758197","wikidata":"https://www.wikidata.org/wiki/Q580018","display_name":"Monetary economics","level":1,"score":0.0},{"id":"https://openalex.org/C151730666","wikidata":"https://www.wikidata.org/wiki/Q7205","display_name":"Paleontology","level":1,"score":0.0},{"id":"https://openalex.org/C2992735868","wikidata":"https://www.wikidata.org/wiki/Q66344","display_name":"Central bank","level":3,"score":0.0}],"mesh":[],"locations_count":4,"locations":[{"id":"doi:10.1109/cdc.2018.8619529","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cdc.2018.8619529","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE Conference on Decision and Control (CDC)","raw_type":"proceedings-article"},{"id":"pmh:oai:pure.atira.dk:openaire/a69a8f17-1b80-4ac2-ae7d-b7c3e64dbf9a","is_oa":true,"landing_page_url":"https://research.manchester.ac.uk/en/publications/a69a8f17-1b80-4ac2-ae7d-b7c3e64dbf9a","pdf_url":null,"source":{"id":"https://openalex.org/S4306400662","display_name":"Research Explorer (The University of Manchester)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I28407311","host_organization_name":"University of Manchester","host_organization_lineage":["https://openalex.org/I28407311"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Bittel, H, Neil Jones, C & Parisio, A 2019, Use of model predictive control for short-term operating reserve using commercial buildings in the United Kingdom context. in 2018 IEEE Conference on Decision and Control (CDC) . https://doi.org/10.1109/cdc.2018.8619529","raw_type":"info:eu-repo/semantics/conferenceObject"},{"id":"pmh:oai:infoscience.epfl.ch:266504","is_oa":true,"landing_page_url":"https://infoscience.epfl.ch/handle/20.500.14299/157069","pdf_url":null,"source":{"id":"https://openalex.org/S4306400487","display_name":"Infoscience (Ecole Polytechnique F\u00e9d\u00e9rale de Lausanne)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"WoS","raw_type":"conference proceedings"},{"id":"pmh:oai:pure.atira.dk:publications/a69a8f17-1b80-4ac2-ae7d-b7c3e64dbf9a","is_oa":false,"landing_page_url":"https://www.research.manchester.ac.uk/portal/en/publications/use-of-model-predictive-control-for-shortterm-operating-reserve-using-commercial-buildings-in-the-united-kingdom-context(a69a8f17-1b80-4ac2-ae7d-b7c3e64dbf9a).html","pdf_url":null,"source":{"id":"https://openalex.org/S4306400662","display_name":"Research Explorer (The University of Manchester)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I28407311","host_organization_name":"University of Manchester","host_organization_lineage":["https://openalex.org/I28407311"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":""}],"best_oa_location":{"id":"pmh:oai:pure.atira.dk:openaire/a69a8f17-1b80-4ac2-ae7d-b7c3e64dbf9a","is_oa":true,"landing_page_url":"https://research.manchester.ac.uk/en/publications/a69a8f17-1b80-4ac2-ae7d-b7c3e64dbf9a","pdf_url":null,"source":{"id":"https://openalex.org/S4306400662","display_name":"Research Explorer (The University of Manchester)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I28407311","host_organization_name":"University of Manchester","host_organization_lineage":["https://openalex.org/I28407311"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Bittel, H, Neil Jones, C & Parisio, A 2019, Use of model predictive control for short-term operating reserve using commercial buildings in the United Kingdom context. in 2018 IEEE Conference on Decision and Control (CDC) . https://doi.org/10.1109/cdc.2018.8619529","raw_type":"info:eu-repo/semantics/conferenceObject"},"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","score":0.5899999737739563,"id":"https://metadata.un.org/sdg/9"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":20,"referenced_works":["https://openalex.org/W1717775628","https://openalex.org/W1926652053","https://openalex.org/W1977985274","https://openalex.org/W2003408565","https://openalex.org/W2013267813","https://openalex.org/W2064999786","https://openalex.org/W2139091700","https://openalex.org/W2143170985","https://openalex.org/W2219134657","https://openalex.org/W2223849598","https://openalex.org/W2536620281","https://openalex.org/W2549691773","https://openalex.org/W2597881582","https://openalex.org/W2615940745","https://openalex.org/W2740213442","https://openalex.org/W2754315630","https://openalex.org/W3021337912","https://openalex.org/W4232504357","https://openalex.org/W6741942689","https://openalex.org/W6744131778"],"related_works":["https://openalex.org/W2555175041","https://openalex.org/W2032085210","https://openalex.org/W2389561653","https://openalex.org/W2052188148","https://openalex.org/W4239205706","https://openalex.org/W1990079087","https://openalex.org/W4239297229","https://openalex.org/W3003695187","https://openalex.org/W2101188133","https://openalex.org/W3166575991"],"abstract_inverted_index":{"Flexibility,":[0],"particularly":[1],"in":[2,51,97,170],"terms":[3],"of":[4,11,17,30,54,84,93,105,123,179],"reserve":[5,110],"services,":[6],"is":[7,62,114,127],"an":[8,167],"essential":[9],"requirement":[10],"power":[12,33,44],"systems":[13],"with":[14,135],"high":[15],"penetration":[16],"renewable":[18,35],"electrical":[19,32],"generation,":[20],"which":[21],"can":[22,68,160],"reduce":[23],"undesirable":[24],"curtailment":[25],"and":[26,126,165],"enable":[27],"higher":[28],"integration":[29],"clean":[31],"from":[34],"generation.":[36],"Reserve":[37,96,164],"services":[38],"are":[39],"related":[40],"to":[41,47,82,115,128],"additional":[42],"active":[43],"sources":[45],"available":[46,118],"the":[48,52,91,98,103,106,112,124,147,176],"grid":[49],"operator":[50],"form":[53],"either":[55],"increased":[56],"generation":[57],"or":[58],"demand":[59],"reduction.":[60],"There":[61],"increasing":[63],"evidence":[64],"that":[65,156],"commercial":[66,88,158],"buildings":[67,89],"provide":[69,161],"such":[70],"reserves.":[71],"In":[72,108],"this":[73,109],"paper":[74],"we":[75],"present":[76],"a":[77,132,136,157,171],"Model":[78],"Predictive":[79],"Control":[80],"approach":[81],"optimization":[83],"flexibility":[85,113],"afforded":[86],"by":[87,146],"for":[90,131],"provision":[92],"Short-Term":[94,162],"Operating":[95,163],"United":[99],"Kingdom":[100],"without":[101,174],"compromising":[102],"comfort":[104,178],"occupants.":[107,180],"scheme":[111],"be":[116,129],"made":[117],"only":[119],"during":[120],"selected":[121],"hours":[122,134],"day":[125],"provided":[130],"few":[133],"slow":[137],"response":[138],"time":[139],"(":[140],"\u2264":[141],"5":[142],"minutes)":[143],"if":[144],"required":[145],"Transmission":[148],"System":[149],"Operator,":[150],"National":[151],"Grid.":[152],"Simulation":[153],"results":[154],"show":[155],"building":[159],"yield":[166],"economic":[168],"benefit":[169],"robust":[172],"manner,":[173],"violating":[175],"indoor":[177]},"counts_by_year":[{"year":2022,"cited_by_count":5},{"year":2020,"cited_by_count":3}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
