{"id":"https://openalex.org/W2068255108","doi":"https://doi.org/10.1109/cdc.2014.7040416","title":"Distributed fault detection in interconnected nonlinear uncertain systems","display_name":"Distributed fault detection in interconnected nonlinear uncertain systems","publication_year":2014,"publication_date":"2014-12-01","ids":{"openalex":"https://openalex.org/W2068255108","doi":"https://doi.org/10.1109/cdc.2014.7040416","mag":"2068255108"},"language":"en","primary_location":{"id":"doi:10.1109/cdc.2014.7040416","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cdc.2014.7040416","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"53rd IEEE Conference on Decision and Control","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5102794829","display_name":"Mohsen Khalili","orcid":"https://orcid.org/0000-0002-7535-2583"},"institutions":[{"id":"https://openalex.org/I19648265","display_name":"Wright State University","ror":"https://ror.org/04qk6pt94","country_code":"US","type":"education","lineage":["https://openalex.org/I19648265"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Mohsen Khalili","raw_affiliation_strings":["Department of Electrical Engineering, Wright State University, Dayton, OH, USA","Department of Electrical Engineering, Wright State University , Dayton, OH 45435 , USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Wright State University, Dayton, OH, USA","institution_ids":["https://openalex.org/I19648265"]},{"raw_affiliation_string":"Department of Electrical Engineering, Wright State University , Dayton, OH 45435 , USA","institution_ids":["https://openalex.org/I19648265"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100376210","display_name":"Xiaodong Zhang","orcid":"https://orcid.org/0000-0002-5717-4111"},"institutions":[{"id":"https://openalex.org/I19648265","display_name":"Wright State University","ror":"https://ror.org/04qk6pt94","country_code":"US","type":"education","lineage":["https://openalex.org/I19648265"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Xiaodong Zhang","raw_affiliation_strings":["Department of Electrical Engineering, Wright State University, Dayton, OH, USA","Department of Electrical Engineering, Wright State University , Dayton, OH 45435 , USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Wright State University, Dayton, OH, USA","institution_ids":["https://openalex.org/I19648265"]},{"raw_affiliation_string":"Department of Electrical Engineering, Wright State University , Dayton, OH 45435 , USA","institution_ids":["https://openalex.org/I19648265"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5102794829"],"corresponding_institution_ids":["https://openalex.org/I19648265"],"apc_list":null,"apc_paid":null,"fwci":0.8115,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.78281009,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"36","issue":null,"first_page":"6548","last_page":"6553"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9987000226974487,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.993399977684021,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/robustness","display_name":"Robustness (evolution)","score":0.8281693458557129},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.7823230624198914},{"id":"https://openalex.org/keywords/nonlinear-system","display_name":"Nonlinear system","score":0.699504017829895},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6110315918922424},{"id":"https://openalex.org/keywords/bounded-function","display_name":"Bounded function","score":0.576440691947937},{"id":"https://openalex.org/keywords/interconnection","display_name":"Interconnection","score":0.5180563926696777},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.5179568529129028},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.4950686991214752},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.46492457389831543},{"id":"https://openalex.org/keywords/fault-tolerance","display_name":"Fault tolerance","score":0.4361972510814667},{"id":"https://openalex.org/keywords/fault-indicator","display_name":"Fault indicator","score":0.42688918113708496},{"id":"https://openalex.org/keywords/stuck-at-fault","display_name":"Stuck-at fault","score":0.41169074177742004},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.36922377347946167},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.34197214245796204},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3133268356323242},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.26455020904541016},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.09471204876899719},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.08247870206832886},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.0742402970790863}],"concepts":[{"id":"https://openalex.org/C63479239","wikidata":"https://www.wikidata.org/wiki/Q7353546","display_name":"Robustness (evolution)","level":3,"score":0.8281693458557129},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.7823230624198914},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.699504017829895},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6110315918922424},{"id":"https://openalex.org/C34388435","wikidata":"https://www.wikidata.org/wiki/Q2267362","display_name":"Bounded function","level":2,"score":0.576440691947937},{"id":"https://openalex.org/C123745756","wikidata":"https://www.wikidata.org/wiki/Q1665949","display_name":"Interconnection","level":2,"score":0.5180563926696777},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5179568529129028},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.4950686991214752},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.46492457389831543},{"id":"https://openalex.org/C63540848","wikidata":"https://www.wikidata.org/wiki/Q3140932","display_name":"Fault tolerance","level":2,"score":0.4361972510814667},{"id":"https://openalex.org/C21267803","wikidata":"https://www.wikidata.org/wiki/Q5438159","display_name":"Fault indicator","level":4,"score":0.42688918113708496},{"id":"https://openalex.org/C13625343","wikidata":"https://www.wikidata.org/wiki/Q7627418","display_name":"Stuck-at fault","level":4,"score":0.41169074177742004},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.36922377347946167},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.34197214245796204},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3133268356323242},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.26455020904541016},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.09471204876899719},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.08247870206832886},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0742402970790863},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.0},{"id":"https://openalex.org/C104317684","wikidata":"https://www.wikidata.org/wiki/Q7187","display_name":"Gene","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/cdc.2014.7040416","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cdc.2014.7040416","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"53rd IEEE Conference on Decision and Control","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W2003530067","https://openalex.org/W2006787156","https://openalex.org/W2032515518","https://openalex.org/W2053842902","https://openalex.org/W2059119683","https://openalex.org/W2059138104","https://openalex.org/W2067603665","https://openalex.org/W2068255108","https://openalex.org/W2110713969","https://openalex.org/W2148743453","https://openalex.org/W2811125079","https://openalex.org/W4237445386"],"related_works":["https://openalex.org/W2544222762","https://openalex.org/W2575775159","https://openalex.org/W2577233154","https://openalex.org/W3186790058","https://openalex.org/W2350226881","https://openalex.org/W190707418","https://openalex.org/W2169757786","https://openalex.org/W2380803702","https://openalex.org/W2164489324","https://openalex.org/W2972711000"],"abstract_inverted_index":{"In":[0],"this":[1],"paper,":[2],"a":[3,11,31],"distributed":[4,84],"fault":[5,40,62,85,106],"detection":[6,41,63,86],"method":[7],"is":[8,23,43,109,133],"developed":[9],"for":[10,45,83],"class":[12,114],"of":[13,33,115,139],"interconnected":[14,50,71],"nonlinear":[15],"uncertain":[16],"systems.":[17],"The":[18],"interconnection":[19],"between":[20],"neighboring":[21,61],"subsystems":[22,67,99],"unknown,":[24],"but":[25],"assumed":[26],"to":[27,72,96,135],"be":[28],"bounded":[29],"by":[30,52,123],"function":[32],"system":[34,51,101,130],"states,":[35],"inputs":[36],"and":[37,56,100],"outputs.":[38],"A":[39,127],"component":[42],"designed":[44],"each":[46,88,118],"subsystem":[47,75,89,119],"in":[48,87,117],"the":[49,73,105,113,124,137,140],"utilizing":[53],"local":[54],"measurements":[55],"certain":[57,79],"communicated":[58],"information":[59],"from":[60],"components":[64],"associated":[65],"with":[66,94],"that":[68,120],"are":[69,90,121],"directly":[70],"particular":[74],"under":[76],"consideration.":[77],"Under":[78],"assumptions,":[80],"adaptive":[81],"thresholds":[82],"derived,":[91],"ensuring":[92],"robustness":[93],"respect":[95],"interconnections":[97],"among":[98],"modeling":[102],"uncertainty.":[103],"Moreover,":[104],"detectability":[107],"condition":[108],"rigorously":[110],"investigated,":[111],"characterizing":[112],"faults":[116],"detectable":[122],"proposed":[125],"method.":[126,141],"multimachine":[128],"power":[129],"simulation":[131],"example":[132],"used":[134],"illustrate":[136],"effectiveness":[138]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2014,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
