{"id":"https://openalex.org/W2062973696","doi":"https://doi.org/10.1109/cdc.2011.6161031","title":"Robust and resilient control design for cyber-physical systems with an application to power systems","display_name":"Robust and resilient control design for cyber-physical systems with an application to power systems","publication_year":2011,"publication_date":"2011-12-01","ids":{"openalex":"https://openalex.org/W2062973696","doi":"https://doi.org/10.1109/cdc.2011.6161031","mag":"2062973696"},"language":"en","primary_location":{"id":"doi:10.1109/cdc.2011.6161031","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cdc.2011.6161031","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Conference on Decision and Control and European Control Conference","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5081500464","display_name":"Quanyan Zhu","orcid":"https://orcid.org/0000-0002-0008-2953"},"institutions":[{"id":"https://openalex.org/I157725225","display_name":"University of Illinois Urbana-Champaign","ror":"https://ror.org/047426m28","country_code":"US","type":"education","lineage":["https://openalex.org/I157725225"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Quanyan Zhu","raw_affiliation_strings":["Department of Electrical & Computer Engineering and Coordinated Science Laboratory, University of Illinois, Urbana-Champaign, Urbana, IL, USA","Department of Electrical & Computer Engineering and Coordinated Science Laboratory, University of Illinois, 1308 West Main St., Urbana, 61801, USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical & Computer Engineering and Coordinated Science Laboratory, University of Illinois, Urbana-Champaign, Urbana, IL, USA","institution_ids":["https://openalex.org/I157725225"]},{"raw_affiliation_string":"Department of Electrical & Computer Engineering and Coordinated Science Laboratory, University of Illinois, 1308 West Main St., Urbana, 61801, USA","institution_ids":["https://openalex.org/I157725225"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5019604570","display_name":"Tamer Ba\u015far","orcid":"https://orcid.org/0000-0003-4406-7875"},"institutions":[{"id":"https://openalex.org/I157725225","display_name":"University of Illinois Urbana-Champaign","ror":"https://ror.org/047426m28","country_code":"US","type":"education","lineage":["https://openalex.org/I157725225"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Tamer Basar","raw_affiliation_strings":["Department of Electrical & Computer Engineering and Coordinated Science Laboratory, University of Illinois, Urbana-Champaign, Urbana, IL, USA","Department of Electrical & Computer Engineering and Coordinated Science Laboratory, University of Illinois, 1308 West Main St., Urbana, 61801, USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical & Computer Engineering and Coordinated Science Laboratory, University of Illinois, Urbana-Champaign, Urbana, IL, USA","institution_ids":["https://openalex.org/I157725225"]},{"raw_affiliation_string":"Department of Electrical & Computer Engineering and Coordinated Science Laboratory, University of Illinois, 1308 West Main St., Urbana, 61801, USA","institution_ids":["https://openalex.org/I157725225"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5081500464"],"corresponding_institution_ids":["https://openalex.org/I157725225"],"apc_list":null,"apc_paid":null,"fwci":19.7082,"has_fulltext":false,"cited_by_count":193,"citation_normalized_percentile":{"value":0.99307524,"is_in_top_1_percent":true,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":98,"max":100},"biblio":{"volume":null,"issue":null,"first_page":"4066","last_page":"4071"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9939000010490417,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9939000010490417,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11807","display_name":"Infrastructure Resilience and Vulnerability Analysis","score":0.972100019454956,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9623000025749207,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/robustness","display_name":"Robustness (evolution)","score":0.753567099571228},{"id":"https://openalex.org/keywords/cyber-physical-system","display_name":"Cyber-physical system","score":0.7369136214256287},{"id":"https://openalex.org/keywords/resilience","display_name":"Resilience (materials science)","score":0.6778639554977417},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6369147896766663},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5607377886772156},{"id":"https://openalex.org/keywords/robust-control","display_name":"Robust control","score":0.5542383790016174},{"id":"https://openalex.org/keywords/critical-infrastructure","display_name":"Critical infrastructure","score":0.5154657959938049},{"id":"https://openalex.org/keywords/industrial-control-system","display_name":"Industrial control system","score":0.514656662940979},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.4584161937236786},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.44448164105415344},{"id":"https://openalex.org/keywords/design-methods","display_name":"Design methods","score":0.4146055579185486},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.3639217019081116},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.3572455644607544},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.2872523069381714},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2471320927143097},{"id":"https://openalex.org/keywords/computer-security","display_name":"Computer security","score":0.2044524848461151}],"concepts":[{"id":"https://openalex.org/C63479239","wikidata":"https://www.wikidata.org/wiki/Q7353546","display_name":"Robustness (evolution)","level":3,"score":0.753567099571228},{"id":"https://openalex.org/C179768478","wikidata":"https://www.wikidata.org/wiki/Q1120057","display_name":"Cyber-physical system","level":2,"score":0.7369136214256287},{"id":"https://openalex.org/C2779585090","wikidata":"https://www.wikidata.org/wiki/Q3457762","display_name":"Resilience (materials science)","level":2,"score":0.6778639554977417},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6369147896766663},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5607377886772156},{"id":"https://openalex.org/C31531917","wikidata":"https://www.wikidata.org/wiki/Q915157","display_name":"Robust control","level":3,"score":0.5542383790016174},{"id":"https://openalex.org/C29852176","wikidata":"https://www.wikidata.org/wiki/Q373338","display_name":"Critical infrastructure","level":2,"score":0.5154657959938049},{"id":"https://openalex.org/C40071531","wikidata":"https://www.wikidata.org/wiki/Q2513962","display_name":"Industrial control system","level":3,"score":0.514656662940979},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.4584161937236786},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.44448164105415344},{"id":"https://openalex.org/C138852830","wikidata":"https://www.wikidata.org/wiki/Q2292993","display_name":"Design methods","level":2,"score":0.4146055579185486},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.3639217019081116},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.3572455644607544},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.2872523069381714},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2471320927143097},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.2044524848461151},{"id":"https://openalex.org/C104317684","wikidata":"https://www.wikidata.org/wiki/Q7187","display_name":"Gene","level":2,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/cdc.2011.6161031","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cdc.2011.6161031","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Conference on Decision and Control and European Control Conference","raw_type":"proceedings-article"},{"id":"pmh:oai:CiteSeerX.psu:10.1.1.462.7972","is_oa":false,"landing_page_url":"http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.462.7972","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"http://www.nt.ntnu.no/users/skoge/prost/proceedings/cdc-ecc-2011/data/papers/1500.pdf","raw_type":"text"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.6299999952316284,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":17,"referenced_works":["https://openalex.org/W191483219","https://openalex.org/W1496590343","https://openalex.org/W1559611566","https://openalex.org/W1579118835","https://openalex.org/W1588998206","https://openalex.org/W1592980365","https://openalex.org/W1977538586","https://openalex.org/W1978083130","https://openalex.org/W2075373489","https://openalex.org/W2084793872","https://openalex.org/W2127546815","https://openalex.org/W2132188011","https://openalex.org/W2135974984","https://openalex.org/W2155122386","https://openalex.org/W2163468230","https://openalex.org/W2174721103","https://openalex.org/W6633338845"],"related_works":["https://openalex.org/W2614996178","https://openalex.org/W3147872107","https://openalex.org/W2289521417","https://openalex.org/W2783141896","https://openalex.org/W2237732271","https://openalex.org/W1980323860","https://openalex.org/W3123953333","https://openalex.org/W2296060994","https://openalex.org/W4366341301","https://openalex.org/W4389543476"],"abstract_inverted_index":{"The":[0,16],"tradeoff":[1],"between":[2,86],"robustness":[3],"and":[4,48,50,77,92,116,139],"resilience":[5,28],"is":[6,39],"a":[7,71,106,113,127,133],"pivotal":[8],"design":[9,80,118,130],"issue":[10],"for":[11,75,112,119,132],"modern":[12],"industrial":[13],"control":[14,23,79],"systems.":[15,121],"trend":[17],"of":[18,32,46,54,61,102,108],"integrating":[19],"information":[20],"technologies":[21],"into":[22],"system":[24],"infrastructure":[25,35],"has":[26],"made":[27],"an":[29],"important":[30],"dimension":[31],"the":[33,59,83,99,141],"critical":[34],"protection":[36],"mission.":[37],"It":[38],"desirable":[40],"that":[41],"systems":[42],"support":[43],"state":[44],"awareness":[45],"threats":[47],"anomalies,":[49],"maintain":[51],"acceptable":[52],"levels":[53],"operation":[55],"or":[56,63],"service":[57],"in":[58,81,95],"face":[60],"unanticipated":[62,90],"unprecedented":[64],"incidents.":[65],"In":[66],"this":[67,124],"paper,":[68],"we":[69],"propose":[70,105],"hybrid":[72],"theoretical":[73],"framework":[74],"robust":[76,115],"resilient":[78,117],"which":[82],"stochastic":[84],"switching":[85],"structure":[87,97],"states":[88],"models":[89],"events":[91],"deterministic":[93],"uncertainties":[94],"each":[96],"represent":[98],"known":[100],"range":[101],"disturbances.":[103],"We":[104,122],"set":[107],"coupled":[109],"optimality":[110],"criteria":[111],"holistic":[114],"cyber-physical":[120],"apply":[123],"method":[125],"to":[126],"voltage":[128],"regulator":[129],"problem":[131],"synchronous":[134],"machine":[135],"with":[136,144],"infinite":[137],"bus":[138],"illustrate":[140],"solution":[142],"methodology":[143],"numerical":[145],"examples.":[146]},"counts_by_year":[{"year":2025,"cited_by_count":8},{"year":2024,"cited_by_count":8},{"year":2023,"cited_by_count":8},{"year":2022,"cited_by_count":13},{"year":2021,"cited_by_count":11},{"year":2020,"cited_by_count":21},{"year":2019,"cited_by_count":31},{"year":2018,"cited_by_count":23},{"year":2017,"cited_by_count":16},{"year":2016,"cited_by_count":15},{"year":2015,"cited_by_count":9},{"year":2014,"cited_by_count":10},{"year":2013,"cited_by_count":14},{"year":2012,"cited_by_count":6}],"updated_date":"2026-04-05T17:49:38.594831","created_date":"2025-10-10T00:00:00"}
