{"id":"https://openalex.org/W1965520488","doi":"https://doi.org/10.1109/cdc.2011.6160742","title":"An integrated multi-task control system for fuel-cell power plants","display_name":"An integrated multi-task control system for fuel-cell power plants","publication_year":2011,"publication_date":"2011-12-01","ids":{"openalex":"https://openalex.org/W1965520488","doi":"https://doi.org/10.1109/cdc.2011.6160742","mag":"1965520488"},"language":"en","primary_location":{"id":"doi:10.1109/cdc.2011.6160742","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cdc.2011.6160742","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Conference on Decision and Control and European Control Conference","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101054525","display_name":"Wenli Yang","orcid":null},"institutions":[{"id":"https://openalex.org/I118271192","display_name":"Western Digital (Japan)","ror":"https://ror.org/0521k5n17","country_code":"JP","type":"company","lineage":["https://openalex.org/I118271192","https://openalex.org/I4210121352"]},{"id":"https://openalex.org/I4210121352","display_name":"Western Digital (United States)","ror":"https://ror.org/02hqwnx33","country_code":"US","type":"company","lineage":["https://openalex.org/I4210121352"]}],"countries":["JP","US"],"is_corresponding":true,"raw_author_name":"Wenli Yang","raw_affiliation_strings":["Western Digital Corporation, Irvine, CA, USA","Western Digital Corporation, Irvine, CA, 92612, USA"],"affiliations":[{"raw_affiliation_string":"Western Digital Corporation, Irvine, CA, USA","institution_ids":["https://openalex.org/I4210121352"]},{"raw_affiliation_string":"Western Digital Corporation, Irvine, CA, 92612, USA","institution_ids":["https://openalex.org/I118271192"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5048238798","display_name":"Kwang Y. Lee","orcid":"https://orcid.org/0000-0002-9965-9117"},"institutions":[{"id":"https://openalex.org/I157394403","display_name":"Baylor University","ror":"https://ror.org/005781934","country_code":"US","type":"education","lineage":["https://openalex.org/I157394403"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Kwang Y. Lee","raw_affiliation_strings":["Department of Electrical & Computer Engineering, Baylor University, Waco, TX, USA","Department of Electrical & Computer Engineering, Baylor University, One Bear Place, Waco, TX 76798-7356, USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical & Computer Engineering, Baylor University, Waco, TX, USA","institution_ids":["https://openalex.org/I157394403"]},{"raw_affiliation_string":"Department of Electrical & Computer Engineering, Baylor University, One Bear Place, Waco, TX 76798-7356, USA","institution_ids":["https://openalex.org/I157394403"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5101054525"],"corresponding_institution_ids":["https://openalex.org/I118271192","https://openalex.org/I4210121352"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.04354923,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"127","issue":null,"first_page":"2988","last_page":"2993"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10409","display_name":"Fuel Cells and Related Materials","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14470","display_name":"Advanced Data Processing Techniques","score":0.9865999817848206,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/power-station","display_name":"Power station","score":0.6084579825401306},{"id":"https://openalex.org/keywords/hybrid-power","display_name":"Hybrid power","score":0.594721794128418},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.5295770168304443},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.5265177488327026},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5216786861419678},{"id":"https://openalex.org/keywords/plant-efficiency","display_name":"Plant efficiency","score":0.514744758605957},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.5140405893325806},{"id":"https://openalex.org/keywords/hybrid-system","display_name":"Hybrid system","score":0.48434674739837646},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.4406711757183075},{"id":"https://openalex.org/keywords/task","display_name":"Task (project management)","score":0.4286876320838928},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4238809049129486},{"id":"https://openalex.org/keywords/fault-tolerance","display_name":"Fault tolerance","score":0.4141484797000885},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3391924798488617},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.2779046893119812},{"id":"https://openalex.org/keywords/systems-engineering","display_name":"Systems engineering","score":0.20899221301078796},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.09510838985443115}],"concepts":[{"id":"https://openalex.org/C4311470","wikidata":"https://www.wikidata.org/wiki/Q159719","display_name":"Power station","level":2,"score":0.6084579825401306},{"id":"https://openalex.org/C86155754","wikidata":"https://www.wikidata.org/wiki/Q13636979","display_name":"Hybrid power","level":3,"score":0.594721794128418},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.5295770168304443},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.5265177488327026},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5216786861419678},{"id":"https://openalex.org/C2779351941","wikidata":"https://www.wikidata.org/wiki/Q7201510","display_name":"Plant efficiency","level":3,"score":0.514744758605957},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5140405893325806},{"id":"https://openalex.org/C50897621","wikidata":"https://www.wikidata.org/wiki/Q2665508","display_name":"Hybrid system","level":2,"score":0.48434674739837646},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4406711757183075},{"id":"https://openalex.org/C2780451532","wikidata":"https://www.wikidata.org/wiki/Q759676","display_name":"Task (project management)","level":2,"score":0.4286876320838928},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4238809049129486},{"id":"https://openalex.org/C63540848","wikidata":"https://www.wikidata.org/wiki/Q3140932","display_name":"Fault tolerance","level":2,"score":0.4141484797000885},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3391924798488617},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.2779046893119812},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.20899221301078796},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.09510838985443115},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/cdc.2011.6160742","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cdc.2011.6160742","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Conference on Decision and Control and European Control Conference","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8299999833106995,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":20,"referenced_works":["https://openalex.org/W105723088","https://openalex.org/W188940501","https://openalex.org/W1482540049","https://openalex.org/W1938618822","https://openalex.org/W2011761651","https://openalex.org/W2018037388","https://openalex.org/W2025535528","https://openalex.org/W2041421635","https://openalex.org/W2087694562","https://openalex.org/W2088555795","https://openalex.org/W2088944105","https://openalex.org/W2101171903","https://openalex.org/W2112465475","https://openalex.org/W2112517200","https://openalex.org/W2120615619","https://openalex.org/W2139582663","https://openalex.org/W2152680124","https://openalex.org/W2158179776","https://openalex.org/W2168798701","https://openalex.org/W2482791116"],"related_works":["https://openalex.org/W2802590190","https://openalex.org/W2028818176","https://openalex.org/W2509148198","https://openalex.org/W2370547093","https://openalex.org/W2373388631","https://openalex.org/W3140184142","https://openalex.org/W2287424425","https://openalex.org/W2370427035","https://openalex.org/W2388379200","https://openalex.org/W1994572476"],"abstract_inverted_index":{"Development":[0],"of":[1,18,47,61,127],"Smart":[2],"Grid":[3],"requires":[4],"power":[5,25,54,114,119],"plants":[6],"to":[7,41,90,96,108],"be":[8],"more":[9],"intelligent,":[10],"efficient,":[11],"and":[12,45,83,87,95,125,133],"reliable,":[13],"which":[14],"raises":[15],"new":[16],"challenges":[17],"the":[19,43,98,113,123,128],"control":[20,33,58,81,129],"system":[21,34,59,89,130],"design":[22],"for":[23,112],"modern":[24],"plants.":[26],"Regarding":[27],"these":[28],"requirements,":[29],"an":[30,72],"integrated":[31,57,107],"multi-task":[32],"using":[35],"artificial":[36],"intelligence":[37],"technologies":[38],"is":[39,121],"proposed":[40],"improve":[42],"efficiency":[44],"reliability":[46],"a":[48,62,84],"hybrid":[49,63,117],"fuel-cell":[50,118],"with":[51,68],"gas":[52],"turbine":[53],"plant.":[55,115],"The":[56,103,116],"consists":[60],"Neural":[64],"Network":[65],"plant":[66,93,99,101,120],"model":[67],"online":[69],"learning":[70],"ability,":[71],"Optimal":[73],"Reference":[74],"Governor":[75],"generating":[76],"optimal":[77],"setpoints":[78],"as":[79],"local":[80],"references,":[82],"Fault":[85],"Diagnosis":[86],"Accommodation":[88],"detect":[91],"internal":[92],"faults":[94],"regulate":[97],"during":[100],"failures.":[102],"three":[104],"subsystems":[105],"are":[106,131,136],"provide":[109],"compressive":[110],"management":[111],"introduced;":[122],"structure":[124],"strategies":[126],"discussed,":[132],"simulation":[134],"results":[135],"presented.":[137]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
