{"id":"https://openalex.org/W1981561274","doi":"https://doi.org/10.1109/cdc.2011.6160375","title":"A nonlinear estimator for dynamical and robust sensorless control of permanent magnet synchronous machines","display_name":"A nonlinear estimator for dynamical and robust sensorless control of permanent magnet synchronous machines","publication_year":2011,"publication_date":"2011-12-01","ids":{"openalex":"https://openalex.org/W1981561274","doi":"https://doi.org/10.1109/cdc.2011.6160375","mag":"1981561274"},"language":"en","primary_location":{"id":"doi:10.1109/cdc.2011.6160375","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cdc.2011.6160375","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Conference on Decision and Control and European Control Conference","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"http://mediatum.ub.tum.de/node?id=1081209","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5071497276","display_name":"Jean-Fran\u00e7ois Stumper","orcid":"https://orcid.org/0009-0004-9961-3241"},"institutions":[{"id":"https://openalex.org/I62916508","display_name":"Technical University of Munich","ror":"https://ror.org/02kkvpp62","country_code":"DE","type":"education","lineage":["https://openalex.org/I62916508"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Jean-Francois Stumper","raw_affiliation_strings":["Department of Electrical Engineering and Information Technology, Technische Universit\u00e4t M\u00fcnchen, Munich, Germany","Department of Electrical Engineering and Information Technology, Technische Universit\u00e4t M\u00fcnchen, Arcisstr. 21, D-80333 Munich, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering and Information Technology, Technische Universit\u00e4t M\u00fcnchen, Munich, Germany","institution_ids":["https://openalex.org/I62916508"]},{"raw_affiliation_string":"Department of Electrical Engineering and Information Technology, Technische Universit\u00e4t M\u00fcnchen, Arcisstr. 21, D-80333 Munich, Germany","institution_ids":["https://openalex.org/I62916508"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5074786170","display_name":"Dirk Paulus","orcid":null},"institutions":[{"id":"https://openalex.org/I62916508","display_name":"Technical University of Munich","ror":"https://ror.org/02kkvpp62","country_code":"DE","type":"education","lineage":["https://openalex.org/I62916508"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Dirk Paulus","raw_affiliation_strings":["Department of Electrical Engineering and Information Technology, Technische Universit\u00e4t M\u00fcnchen, Munich, Germany","Department of Electrical Engineering and Information Technology, Technische Universit\u00e4t M\u00fcnchen, Arcisstr. 21, D-80333 Munich, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering and Information Technology, Technische Universit\u00e4t M\u00fcnchen, Munich, Germany","institution_ids":["https://openalex.org/I62916508"]},{"raw_affiliation_string":"Department of Electrical Engineering and Information Technology, Technische Universit\u00e4t M\u00fcnchen, Arcisstr. 21, D-80333 Munich, Germany","institution_ids":["https://openalex.org/I62916508"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5041181114","display_name":"Ralph Kennel","orcid":"https://orcid.org/0000-0003-4997-0043"},"institutions":[{"id":"https://openalex.org/I62916508","display_name":"Technical University of Munich","ror":"https://ror.org/02kkvpp62","country_code":"DE","type":"education","lineage":["https://openalex.org/I62916508"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Ralph Kennel","raw_affiliation_strings":["Department of Electrical Engineering and Information Technology, Technische Universit\u00e4t M\u00fcnchen, Munich, Germany","Department of Electrical Engineering and Information Technology, Technische Universit\u00e4t M\u00fcnchen, Arcisstr. 21, D-80333 Munich, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering and Information Technology, Technische Universit\u00e4t M\u00fcnchen, Munich, Germany","institution_ids":["https://openalex.org/I62916508"]},{"raw_affiliation_string":"Department of Electrical Engineering and Information Technology, Technische Universit\u00e4t M\u00fcnchen, Arcisstr. 21, D-80333 Munich, Germany","institution_ids":["https://openalex.org/I62916508"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I62916508"],"apc_list":null,"apc_paid":null,"fwci":2.685,"has_fulltext":false,"cited_by_count":8,"citation_normalized_percentile":{"value":0.89401456,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":96},"biblio":{"volume":"48","issue":null,"first_page":"922","last_page":"927"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.998199999332428,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11602","display_name":"Magnetic Bearings and Levitation Dynamics","score":0.991100013256073,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.8751519322395325},{"id":"https://openalex.org/keywords/robustness","display_name":"Robustness (evolution)","score":0.7197080850601196},{"id":"https://openalex.org/keywords/stator","display_name":"Stator","score":0.6880849599838257},{"id":"https://openalex.org/keywords/estimator","display_name":"Estimator","score":0.6306235790252686},{"id":"https://openalex.org/keywords/parametric-statistics","display_name":"Parametric statistics","score":0.575121283531189},{"id":"https://openalex.org/keywords/nonlinear-system","display_name":"Nonlinear system","score":0.5239236950874329},{"id":"https://openalex.org/keywords/robust-control","display_name":"Robust control","score":0.48907357454299927},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.48281988501548767},{"id":"https://openalex.org/keywords/rotor","display_name":"Rotor (electric)","score":0.4701307713985443},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.45286625623703003},{"id":"https://openalex.org/keywords/observer","display_name":"Observer (physics)","score":0.4456501603126526},{"id":"https://openalex.org/keywords/magnet","display_name":"Magnet","score":0.44428667426109314},{"id":"https://openalex.org/keywords/synchronous-motor","display_name":"Synchronous motor","score":0.4326878786087036},{"id":"https://openalex.org/keywords/permanent-magnet-synchronous-motor","display_name":"Permanent magnet synchronous motor","score":0.4229656755924225},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.330155611038208},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.24982669949531555},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.23423898220062256},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.08959537744522095}],"concepts":[{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.8751519322395325},{"id":"https://openalex.org/C63479239","wikidata":"https://www.wikidata.org/wiki/Q7353546","display_name":"Robustness (evolution)","level":3,"score":0.7197080850601196},{"id":"https://openalex.org/C2776529397","wikidata":"https://www.wikidata.org/wiki/Q190312","display_name":"Stator","level":2,"score":0.6880849599838257},{"id":"https://openalex.org/C185429906","wikidata":"https://www.wikidata.org/wiki/Q1130160","display_name":"Estimator","level":2,"score":0.6306235790252686},{"id":"https://openalex.org/C117251300","wikidata":"https://www.wikidata.org/wiki/Q1849855","display_name":"Parametric statistics","level":2,"score":0.575121283531189},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.5239236950874329},{"id":"https://openalex.org/C31531917","wikidata":"https://www.wikidata.org/wiki/Q915157","display_name":"Robust control","level":3,"score":0.48907357454299927},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.48281988501548767},{"id":"https://openalex.org/C17281054","wikidata":"https://www.wikidata.org/wiki/Q193466","display_name":"Rotor (electric)","level":2,"score":0.4701307713985443},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.45286625623703003},{"id":"https://openalex.org/C2780704645","wikidata":"https://www.wikidata.org/wiki/Q9251458","display_name":"Observer (physics)","level":2,"score":0.4456501603126526},{"id":"https://openalex.org/C16389437","wikidata":"https://www.wikidata.org/wiki/Q11421","display_name":"Magnet","level":2,"score":0.44428667426109314},{"id":"https://openalex.org/C71376005","wikidata":"https://www.wikidata.org/wiki/Q845675","display_name":"Synchronous motor","level":2,"score":0.4326878786087036},{"id":"https://openalex.org/C2986944758","wikidata":"https://www.wikidata.org/wiki/Q845675","display_name":"Permanent magnet synchronous motor","level":3,"score":0.4229656755924225},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.330155611038208},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.24982669949531555},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.23423898220062256},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.08959537744522095},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0},{"id":"https://openalex.org/C104317684","wikidata":"https://www.wikidata.org/wiki/Q7187","display_name":"Gene","level":2,"score":0.0},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/cdc.2011.6160375","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cdc.2011.6160375","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Conference on Decision and Control and European Control Conference","raw_type":"proceedings-article"},{"id":"pmh:oai:mediatum.ub.tum.de:node/1081209","is_oa":true,"landing_page_url":"http://mediatum.ub.tum.de/node?id=1081209","pdf_url":null,"source":{"id":"https://openalex.org/S4306400453","display_name":"mediaTUM \u2013 the media and publications repository of the Technical University Munich (Technical University Munich)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I62916508","host_organization_name":"Technical University of Munich","host_organization_lineage":["https://openalex.org/I62916508"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"article"},{"id":"pmh:oai:mediatum.ub.tum.de:node/1081210","is_oa":true,"landing_page_url":"http://mediatum.ub.tum.de/node?id=1081210","pdf_url":null,"source":{"id":"https://openalex.org/S4306400453","display_name":"mediaTUM \u2013 the media and publications repository of the Technical University Munich (Technical University Munich)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I62916508","host_organization_name":"Technical University of Munich","host_organization_lineage":["https://openalex.org/I62916508"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"article"}],"best_oa_location":{"id":"pmh:oai:mediatum.ub.tum.de:node/1081209","is_oa":true,"landing_page_url":"http://mediatum.ub.tum.de/node?id=1081209","pdf_url":null,"source":{"id":"https://openalex.org/S4306400453","display_name":"mediaTUM \u2013 the media and publications repository of the Technical University Munich (Technical University Munich)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I62916508","host_organization_name":"Technical University of Munich","host_organization_lineage":["https://openalex.org/I62916508"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"article"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.7599999904632568}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W48920821","https://openalex.org/W1543104006","https://openalex.org/W1633459523","https://openalex.org/W1965480824","https://openalex.org/W2005747952","https://openalex.org/W2096904205","https://openalex.org/W2104598458","https://openalex.org/W2117964479","https://openalex.org/W2122339259","https://openalex.org/W2122829062","https://openalex.org/W2144843012","https://openalex.org/W2146156574","https://openalex.org/W2146993109","https://openalex.org/W2153739093","https://openalex.org/W2163473812","https://openalex.org/W6682942634"],"related_works":["https://openalex.org/W1989707656","https://openalex.org/W4252156693","https://openalex.org/W4387638577","https://openalex.org/W2355594986","https://openalex.org/W2144803608","https://openalex.org/W2087042126","https://openalex.org/W4242196303","https://openalex.org/W2615749722","https://openalex.org/W4400772239","https://openalex.org/W2082330079"],"abstract_inverted_index":{"This":[0],"paper":[1],"proposes":[2],"an":[3,37],"angular":[4],"position":[5,45],"and":[6,46,56,70,89,99,127],"speed":[7,47,72],"estimation":[8,40,75],"scheme":[9,116,134],"that":[10,101],"is":[11,36,76,96,104,110,117,135],"based":[12,51],"on":[13,52],"a":[14,30,123],"direct":[15],"evaluation":[16],"of":[17,20,29,122,132],"the":[18,21,25,43,57,133],"angle":[19,109],"voltage":[22,59],"induced":[23],"by":[24,137],"spinning":[26],"rotor":[27,44],"(back-EMF)":[28],"permanent-magnet":[31],"synchronous":[32],"motor":[33],"(PMSM).":[34],"It":[35,95],"inverse":[38],"parallel-model":[39],"method,":[41],"meaning":[42],"are":[48,80],"directly":[49,90],"calculated":[50],"stator":[53,58],"current":[54],"measurements":[55],"commands.":[60],"In":[61],"contrast":[62],"to":[63,84],"existing":[64],"schemes,":[65],"no":[66,68,71],"observer,":[67],"integration":[69],"or":[73],"flux":[74],"necessary.":[77],"The":[78,106,115,130],"estimators":[79],"extended":[81],"with":[82,86],"filters":[83],"cope":[85],"measurement":[87],"noise,":[88],"used":[91],"for":[92,119],"field-oriented":[93],"control.":[94],"shown":[97],"algebraically":[98],"experimentally":[100],"parametric":[102],"robustness":[103],"outstanding.":[105],"resulting":[107],"estimated":[108],"driftless":[111],"even":[112],"under":[113],"uncertainties.":[114],"suitable":[118],"encoderless":[120],"control":[121],"PMSM":[124],"at":[125],"high":[126],"low":[128],"speeds.":[129],"performance":[131],"confirmed":[136],"experimental":[138],"results.":[139]},"counts_by_year":[{"year":2019,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2013,"cited_by_count":2},{"year":2012,"cited_by_count":2}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
