{"id":"https://openalex.org/W2158459582","doi":"https://doi.org/10.1109/cdc.2010.5717267","title":"Averaged alarm delay and systematic design for alarm systems","display_name":"Averaged alarm delay and systematic design for alarm systems","publication_year":2010,"publication_date":"2010-12-01","ids":{"openalex":"https://openalex.org/W2158459582","doi":"https://doi.org/10.1109/cdc.2010.5717267","mag":"2158459582"},"language":"en","primary_location":{"id":"doi:10.1109/cdc.2010.5717267","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cdc.2010.5717267","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"49th IEEE Conference on Decision and Control (CDC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5003175299","display_name":"Jianwei Xu","orcid":null},"institutions":[{"id":"https://openalex.org/I20231570","display_name":"Peking University","ror":"https://ror.org/02v51f717","country_code":"CN","type":"education","lineage":["https://openalex.org/I20231570"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Jianwei Xu","raw_affiliation_strings":["College of Engineering, Peking University, Beijing, China"],"affiliations":[{"raw_affiliation_string":"College of Engineering, Peking University, Beijing, China","institution_ids":["https://openalex.org/I20231570"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100444318","display_name":"Jiandong Wang","orcid":"https://orcid.org/0000-0003-2635-8724"},"institutions":[{"id":"https://openalex.org/I20231570","display_name":"Peking University","ror":"https://ror.org/02v51f717","country_code":"CN","type":"education","lineage":["https://openalex.org/I20231570"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jiandong Wang","raw_affiliation_strings":["College of Engineering, Peking University, Beijing, China"],"affiliations":[{"raw_affiliation_string":"College of Engineering, Peking University, Beijing, China","institution_ids":["https://openalex.org/I20231570"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5003175299"],"corresponding_institution_ids":["https://openalex.org/I20231570"],"apc_list":null,"apc_paid":null,"fwci":2.1678,"has_fulltext":false,"cited_by_count":13,"citation_normalized_percentile":{"value":0.89920683,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"6821","last_page":"6826"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9835000038146973,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11443","display_name":"Advanced Statistical Process Monitoring","score":0.957099974155426,"subfield":{"id":"https://openalex.org/subfields/1804","display_name":"Statistics, Probability and Uncertainty"},"field":{"id":"https://openalex.org/fields/18","display_name":"Decision Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/alarm","display_name":"ALARM","score":0.9328864812850952},{"id":"https://openalex.org/keywords/univariate","display_name":"Univariate","score":0.6153556108474731},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6119410395622253},{"id":"https://openalex.org/keywords/constant-false-alarm-rate","display_name":"Constant false alarm rate","score":0.5700829029083252},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.5228341221809387},{"id":"https://openalex.org/keywords/manual-fire-alarm-activation","display_name":"Manual fire alarm activation","score":0.5004658699035645},{"id":"https://openalex.org/keywords/computation","display_name":"Computation","score":0.4828701317310333},{"id":"https://openalex.org/keywords/false-alarm","display_name":"False alarm","score":0.41198503971099854},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.2872702479362488},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.27994248270988464},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.17662248015403748},{"id":"https://openalex.org/keywords/machine-learning","display_name":"Machine learning","score":0.148970365524292},{"id":"https://openalex.org/keywords/multivariate-statistics","display_name":"Multivariate statistics","score":0.09075066447257996}],"concepts":[{"id":"https://openalex.org/C2779119184","wikidata":"https://www.wikidata.org/wiki/Q294350","display_name":"ALARM","level":2,"score":0.9328864812850952},{"id":"https://openalex.org/C199163554","wikidata":"https://www.wikidata.org/wiki/Q1681619","display_name":"Univariate","level":3,"score":0.6153556108474731},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6119410395622253},{"id":"https://openalex.org/C77052588","wikidata":"https://www.wikidata.org/wiki/Q644307","display_name":"Constant false alarm rate","level":2,"score":0.5700829029083252},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.5228341221809387},{"id":"https://openalex.org/C194305327","wikidata":"https://www.wikidata.org/wiki/Q1022253","display_name":"Manual fire alarm activation","level":3,"score":0.5004658699035645},{"id":"https://openalex.org/C45374587","wikidata":"https://www.wikidata.org/wiki/Q12525525","display_name":"Computation","level":2,"score":0.4828701317310333},{"id":"https://openalex.org/C2776836416","wikidata":"https://www.wikidata.org/wiki/Q1364844","display_name":"False alarm","level":2,"score":0.41198503971099854},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.2872702479362488},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.27994248270988464},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.17662248015403748},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.148970365524292},{"id":"https://openalex.org/C161584116","wikidata":"https://www.wikidata.org/wiki/Q1952580","display_name":"Multivariate statistics","level":2,"score":0.09075066447257996},{"id":"https://openalex.org/C146978453","wikidata":"https://www.wikidata.org/wiki/Q3798668","display_name":"Aerospace engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/cdc.2010.5717267","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cdc.2010.5717267","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"49th IEEE Conference on Decision and Control (CDC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W1774777405","https://openalex.org/W1965742201","https://openalex.org/W1975784802","https://openalex.org/W1997765246","https://openalex.org/W2003132506","https://openalex.org/W2018096934","https://openalex.org/W2036488048","https://openalex.org/W2157202423","https://openalex.org/W4205431151","https://openalex.org/W4249552344","https://openalex.org/W4285719527","https://openalex.org/W6638191807","https://openalex.org/W6641426105","https://openalex.org/W6644230439","https://openalex.org/W6740024554","https://openalex.org/W7010541305"],"related_works":["https://openalex.org/W2368114419","https://openalex.org/W4376273903","https://openalex.org/W2791645715","https://openalex.org/W2366733072","https://openalex.org/W2347910141","https://openalex.org/W2379953004","https://openalex.org/W2992246749","https://openalex.org/W2050616060","https://openalex.org/W2026914067","https://openalex.org/W4379535633"],"abstract_inverted_index":{"The":[0,101],"performance":[1,99],"of":[2,54,61,75],"a":[3,67,87],"univariate":[4],"alarm":[5,19,23,28,62,76,80,91,128],"system":[6,129],"can":[7],"be":[8],"assessed":[9],"in":[10],"many":[11],"cases":[12],"by":[13,78],"three":[14,98],"indices,":[15],"namely,":[16],"the":[17,34,38,50,55,58,72,97,116,121,126],"false":[18],"rate":[20,24],"(FAR),":[21],"missed":[22],"(MAR)":[25],"and":[26,36,52,70,82,106,123],"averaged":[27],"delay":[29],"(AAD).":[30],"By":[31],"contrast":[32],"to":[33,114,124],"FAR":[35],"MAR,":[37],"AAD":[39,56,107,122],"seemingly":[40],"has":[41],"been":[42],"received":[43],"litter":[44],"attention.":[45],"This":[46],"paper":[47],"firstly":[48],"studies":[49],"definition":[51],"computation":[53],"for":[57,71,90],"basic":[59],"mechanism":[60,74],"generation":[63,77],"solely":[64],"based":[65,95],"on":[66,96,120],"trip":[68],"point,":[69],"advanced":[73],"exploiting":[79],"on-delays":[81],"moving":[83],"average":[84],"filters.":[85],"Secondly,":[86],"systematic":[88],"design":[89,130],"systems":[92],"is":[93],"proposed":[94,127],"indices.":[100],"trade-offs":[102],"among":[103],"FAR,":[104],"MAR":[105],"are":[108,112],"investigated.":[109],"Numerical":[110],"examples":[111],"provided":[113],"validate":[115],"obtained":[117],"theoretical":[118],"results":[119],"illustrate":[125],"procedure.":[131]},"counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":3},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
