{"id":"https://openalex.org/W4414117746","doi":"https://doi.org/10.1109/ccta53793.2025.11151307","title":"A Modular Local Supervisory Control Approach for Microgrids Power Management System Design with Hardware-in-the-Loop Validation","display_name":"A Modular Local Supervisory Control Approach for Microgrids Power Management System Design with Hardware-in-the-Loop Validation","publication_year":2025,"publication_date":"2025-08-25","ids":{"openalex":"https://openalex.org/W4414117746","doi":"https://doi.org/10.1109/ccta53793.2025.11151307"},"language":"en","primary_location":{"id":"doi:10.1109/ccta53793.2025.11151307","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ccta53793.2025.11151307","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE Conference on Control Technology and Applications (CCTA)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5022742795","display_name":"Renan Emanuelli Rotunno","orcid":null},"institutions":[{"id":"https://openalex.org/I122140584","display_name":"Universidade Federal do Rio de Janeiro","ror":"https://ror.org/03490as77","country_code":"BR","type":"education","lineage":["https://openalex.org/I122140584"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Renan E. Rotunno","raw_affiliation_strings":["Federal University of Rio de Janeiro, Electrical Engineering Program, COPPE/UFRJ"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Federal University of Rio de Janeiro, Electrical Engineering Program, COPPE/UFRJ","institution_ids":["https://openalex.org/I122140584"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Andr\u00e9 Rangel","orcid":null},"institutions":[{"id":"https://openalex.org/I122140584","display_name":"Universidade Federal do Rio de Janeiro","ror":"https://ror.org/03490as77","country_code":"BR","type":"education","lineage":["https://openalex.org/I122140584"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Andr\u00e9 Rangel","raw_affiliation_strings":["Federal University of Rio de Janeiro, Electrical Engineering Program, COPPE/UFRJ"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Federal University of Rio de Janeiro, Electrical Engineering Program, COPPE/UFRJ","institution_ids":["https://openalex.org/I122140584"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5119589205","display_name":"Thamiris Bernardo","orcid":null},"institutions":[{"id":"https://openalex.org/I122140584","display_name":"Universidade Federal do Rio de Janeiro","ror":"https://ror.org/03490as77","country_code":"BR","type":"education","lineage":["https://openalex.org/I122140584"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Thamiris Bernardo","raw_affiliation_strings":["Federal University of Rio de Janeiro, Electrical Engineering Program, COPPE/UFRJ"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Federal University of Rio de Janeiro, Electrical Engineering Program, COPPE/UFRJ","institution_ids":["https://openalex.org/I122140584"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5039874372","display_name":"Gustavo S. Viana","orcid":"https://orcid.org/0000-0002-9444-9372"},"institutions":[{"id":"https://openalex.org/I122140584","display_name":"Universidade Federal do Rio de Janeiro","ror":"https://ror.org/03490as77","country_code":"BR","type":"education","lineage":["https://openalex.org/I122140584"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Gustavo Viana","raw_affiliation_strings":["Federal University of Rio de Janeiro, Electrical Engineering Program, COPPE/UFRJ"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Federal University of Rio de Janeiro, Electrical Engineering Program, COPPE/UFRJ","institution_ids":["https://openalex.org/I122140584"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5016795308","display_name":"Thiago M. Tuxi","orcid":null},"institutions":[{"id":"https://openalex.org/I4210136482","display_name":"Federal Center for Technological Education of Minas Gerais","ror":"https://ror.org/04ch49185","country_code":"BR","type":"education","lineage":["https://openalex.org/I4210136482"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Thiago Tuxi","raw_affiliation_strings":["CEFET/RJ,Federal Center of Technological Education, Control and Automation Engineering Program"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"CEFET/RJ,Federal Center of Technological Education, Control and Automation Engineering Program","institution_ids":["https://openalex.org/I4210136482"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5000030586","display_name":"Robson F. S. Dias","orcid":"https://orcid.org/0000-0002-5281-9179"},"institutions":[{"id":"https://openalex.org/I122140584","display_name":"Universidade Federal do Rio de Janeiro","ror":"https://ror.org/03490as77","country_code":"BR","type":"education","lineage":["https://openalex.org/I122140584"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Robson Dias","raw_affiliation_strings":["Federal University of Rio de Janeiro, Electrical Engineering Program, COPPE/UFRJ"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Federal University of Rio de Janeiro, Electrical Engineering Program, COPPE/UFRJ","institution_ids":["https://openalex.org/I122140584"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.26092906,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"794","last_page":"799"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9977999925613403,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9977999925613403,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9902999997138977,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9864000082015991,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/modular-design","display_name":"Modular design","score":0.7843000292778015},{"id":"https://openalex.org/keywords/supervisory-control","display_name":"Supervisory control","score":0.753000020980835},{"id":"https://openalex.org/keywords/state-of-charge","display_name":"State of charge","score":0.5368000268936157},{"id":"https://openalex.org/keywords/energy-management-system","display_name":"Energy management system","score":0.5108000040054321},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.48350000381469727},{"id":"https://openalex.org/keywords/state","display_name":"State (computer science)","score":0.47780001163482666},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.46399998664855957},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.46050000190734863},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.45829999446868896},{"id":"https://openalex.org/keywords/power-management","display_name":"Power management","score":0.4377000033855438}],"concepts":[{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.7843000292778015},{"id":"https://openalex.org/C92991967","wikidata":"https://www.wikidata.org/wiki/Q7644329","display_name":"Supervisory control","level":3,"score":0.753000020980835},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.5698000192642212},{"id":"https://openalex.org/C2776582896","wikidata":"https://www.wikidata.org/wiki/Q5368536","display_name":"State of charge","level":4,"score":0.5368000268936157},{"id":"https://openalex.org/C2781260460","wikidata":"https://www.wikidata.org/wiki/Q6139999","display_name":"Energy management system","level":4,"score":0.5108000040054321},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.48350000381469727},{"id":"https://openalex.org/C48103436","wikidata":"https://www.wikidata.org/wiki/Q599031","display_name":"State (computer science)","level":2,"score":0.47780001163482666},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.47049999237060547},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.46399998664855957},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.46050000190734863},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.45829999446868896},{"id":"https://openalex.org/C2778774385","wikidata":"https://www.wikidata.org/wiki/Q4437810","display_name":"Power management","level":3,"score":0.4377000033855438},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4219000041484833},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.39910000562667847},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.3970000147819519},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.37529999017715454},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.36480000615119934},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.35010001063346863},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.3391999900341034},{"id":"https://openalex.org/C2778693208","wikidata":"https://www.wikidata.org/wiki/Q7644327","display_name":"Supervisory control theory","level":4,"score":0.33649998903274536},{"id":"https://openalex.org/C168167062","wikidata":"https://www.wikidata.org/wiki/Q1117970","display_name":"Component (thermodynamics)","level":2,"score":0.3278999924659729},{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.3278000056743622},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.32659998536109924},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.3221000134944916},{"id":"https://openalex.org/C31352089","wikidata":"https://www.wikidata.org/wiki/Q3750474","display_name":"Systems design","level":2,"score":0.3188999891281128},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.31450000405311584},{"id":"https://openalex.org/C2983254600","wikidata":"https://www.wikidata.org/wiki/Q1096907","display_name":"Power grid","level":3,"score":0.30640000104904175},{"id":"https://openalex.org/C198783460","wikidata":"https://www.wikidata.org/wiki/Q629173","display_name":"Management system","level":2,"score":0.29660001397132874},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.29649999737739563},{"id":"https://openalex.org/C138852830","wikidata":"https://www.wikidata.org/wiki/Q2292993","display_name":"Design methods","level":2,"score":0.27239999175071716},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.26440000534057617},{"id":"https://openalex.org/C64346931","wikidata":"https://www.wikidata.org/wiki/Q4519148","display_name":"Functional design","level":2,"score":0.2621000111103058},{"id":"https://openalex.org/C2778363213","wikidata":"https://www.wikidata.org/wiki/Q16938469","display_name":"Power management system","level":4,"score":0.2603999972343445},{"id":"https://openalex.org/C124216869","wikidata":"https://www.wikidata.org/wiki/Q7621833","display_name":"Design strategy","level":2,"score":0.2515000104904175}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ccta53793.2025.11151307","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ccta53793.2025.11151307","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE Conference on Control Technology and Applications (CCTA)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W1554301460","https://openalex.org/W1991971024","https://openalex.org/W2059057465","https://openalex.org/W2097811416","https://openalex.org/W2463802320","https://openalex.org/W2509841691","https://openalex.org/W2518965400","https://openalex.org/W2752255456","https://openalex.org/W2766557923","https://openalex.org/W2797780621","https://openalex.org/W2883728796","https://openalex.org/W2913231044","https://openalex.org/W3018690990","https://openalex.org/W3157815906","https://openalex.org/W3200232598","https://openalex.org/W4384436086"],"related_works":["https://openalex.org/W1552815313","https://openalex.org/W24774503","https://openalex.org/W3028107872","https://openalex.org/W2182871100","https://openalex.org/W2122920927","https://openalex.org/W2353922510","https://openalex.org/W2014821076","https://openalex.org/W2378076731","https://openalex.org/W2159184825","https://openalex.org/W4214749219"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"an":[3],"implementation":[4,84],"strategy":[5],"for":[6,11,29],"Power":[7],"Management":[8],"Systems":[9],"(PMSs)":[10],"microgrids":[12],"(MGs)":[13],"using":[14,81],"supervisory":[15],"control":[16],"theory":[17],"(SCT).":[18],"More":[19],"specifically,":[20],"the":[21,25,34,43,46,52,68],"present":[22],"design":[23,44],"utilizes":[24],"modular":[26],"local":[27],"approach":[28,74],"synthesizing":[30],"essential":[31],"functionalities":[32],"of":[33,48,51],"PMS,":[35],"including":[36],"peak":[37],"shaving":[38],"and":[39,60,90],"load":[40],"shedding.":[41],"Additionally,":[42],"guarantees":[45],"State":[47],"Charge":[49],"(SOC)":[50],"Battery":[53],"Energy":[54],"System":[55],"(BESS)":[56],"within":[57],"safe":[58],"values":[59],"coordinates":[61],"its":[62],"operation":[63],"to":[64,67],"supply":[65],"power":[66],"grid":[69],"during":[70],"low-power":[71],"periods.":[72],"The":[73],"is":[75],"validated":[76],"through":[77],"a":[78,82,86,91],"case":[79],"study":[80],"Hardware-In-the-Loop":[83],"with":[85],"Raspberry":[87],"Pi":[88],"5":[89],"real-time":[92],"simulator":[93],"OPAL-RT.":[94]},"counts_by_year":[],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
