{"id":"https://openalex.org/W4414117753","doi":"https://doi.org/10.1109/ccta53793.2025.11151283","title":"A Modular Safety Filter for Safety-Certified Cyber-Physical Systems","display_name":"A Modular Safety Filter for Safety-Certified Cyber-Physical Systems","publication_year":2025,"publication_date":"2025-08-25","ids":{"openalex":"https://openalex.org/W4414117753","doi":"https://doi.org/10.1109/ccta53793.2025.11151283"},"language":"en","primary_location":{"id":"doi:10.1109/ccta53793.2025.11151283","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ccta53793.2025.11151283","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE Conference on Control Technology and Applications (CCTA)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5029021519","display_name":"Mohammad Bajelani","orcid":"https://orcid.org/0000-0002-0414-2677"},"institutions":[{"id":"https://openalex.org/I4405260628","display_name":"University of British Columbia, Okanagan Campus","ror":"https://ror.org/04241wz75","country_code":"CA","type":"education","lineage":["https://openalex.org/I141945490","https://openalex.org/I4405260628"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Mohammad Bajelani","raw_affiliation_strings":["University of British Columbia, School of Engineering,Kelowna,BC,Canada,V1V 1V7"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of British Columbia, School of Engineering,Kelowna,BC,Canada,V1V 1V7","institution_ids":["https://openalex.org/I4405260628"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5014915405","display_name":"Mehran Attar","orcid":null},"institutions":[{"id":"https://openalex.org/I60158472","display_name":"Concordia University","ror":"https://ror.org/0420zvk78","country_code":"CA","type":"education","lineage":["https://openalex.org/I60158472"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Mehran Attar","raw_affiliation_strings":["Concordia Institute for Information Systems Engineering (CIISE), Concordia University,Montreal,QC,Canada,H3G 1M8"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Concordia Institute for Information Systems Engineering (CIISE), Concordia University,Montreal,QC,Canada,H3G 1M8","institution_ids":["https://openalex.org/I60158472"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5084252716","display_name":"Walter L\u00facia","orcid":"https://orcid.org/0000-0003-3776-8331"},"institutions":[{"id":"https://openalex.org/I60158472","display_name":"Concordia University","ror":"https://ror.org/0420zvk78","country_code":"CA","type":"education","lineage":["https://openalex.org/I60158472"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Walter Lucia","raw_affiliation_strings":["Concordia Institute for Information Systems Engineering (CIISE), Concordia University,Montreal,QC,Canada,H3G 1M8"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Concordia Institute for Information Systems Engineering (CIISE), Concordia University,Montreal,QC,Canada,H3G 1M8","institution_ids":["https://openalex.org/I60158472"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5009577016","display_name":"Klaske van Heusden","orcid":"https://orcid.org/0000-0003-2763-5279"},"institutions":[{"id":"https://openalex.org/I4405260628","display_name":"University of British Columbia, Okanagan Campus","ror":"https://ror.org/04241wz75","country_code":"CA","type":"education","lineage":["https://openalex.org/I141945490","https://openalex.org/I4405260628"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Klaske Van Heusden","raw_affiliation_strings":["University of British Columbia, School of Engineering,Kelowna,BC,Canada,V1V 1V7"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of British Columbia, School of Engineering,Kelowna,BC,Canada,V1V 1V7","institution_ids":["https://openalex.org/I4405260628"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.9133,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.76612764,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"880","last_page":"885"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13295","display_name":"Safety Systems Engineering in Autonomy","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T13295","display_name":"Safety Systems Engineering in Autonomy","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11357","display_name":"Risk and Safety Analysis","score":0.9980999827384949,"subfield":{"id":"https://openalex.org/subfields/1804","display_name":"Statistics, Probability and Uncertainty"},"field":{"id":"https://openalex.org/fields/18","display_name":"Decision Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/modular-design","display_name":"Modular design","score":0.7394000291824341},{"id":"https://openalex.org/keywords/filter","display_name":"Filter (signal processing)","score":0.6389999985694885},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.632099986076355},{"id":"https://openalex.org/keywords/system-safety","display_name":"System safety","score":0.5281000137329102},{"id":"https://openalex.org/keywords/task","display_name":"Task (project management)","score":0.512499988079071},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.41929998993873596},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.4090999960899353}],"concepts":[{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.7394000291824341},{"id":"https://openalex.org/C106131492","wikidata":"https://www.wikidata.org/wiki/Q3072260","display_name":"Filter (signal processing)","level":2,"score":0.6389999985694885},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.632099986076355},{"id":"https://openalex.org/C132835097","wikidata":"https://www.wikidata.org/wiki/Q7663745","display_name":"System safety","level":2,"score":0.5281000137329102},{"id":"https://openalex.org/C2780451532","wikidata":"https://www.wikidata.org/wiki/Q759676","display_name":"Task (project management)","level":2,"score":0.512499988079071},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5051000118255615},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.4726000130176544},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.42899999022483826},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.41929998993873596},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.4090999960899353},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.3944999873638153},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.38830000162124634},{"id":"https://openalex.org/C59656382","wikidata":"https://www.wikidata.org/wiki/Q191536","display_name":"Conjunction (astronomy)","level":2,"score":0.3725999891757965},{"id":"https://openalex.org/C22597639","wikidata":"https://www.wikidata.org/wiki/Q5449227","display_name":"Filter design","level":3,"score":0.34459999203681946},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.31209999322891235},{"id":"https://openalex.org/C45374587","wikidata":"https://www.wikidata.org/wiki/Q12525525","display_name":"Computation","level":2,"score":0.30250000953674316},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.2971999943256378},{"id":"https://openalex.org/C148493468","wikidata":"https://www.wikidata.org/wiki/Q2646951","display_name":"Functional safety","level":2,"score":0.288100004196167},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.27059999108314514},{"id":"https://openalex.org/C2779662365","wikidata":"https://www.wikidata.org/wiki/Q5416694","display_name":"Event (particle physics)","level":2,"score":0.2700999975204468},{"id":"https://openalex.org/C168167062","wikidata":"https://www.wikidata.org/wiki/Q1117970","display_name":"Component (thermodynamics)","level":2,"score":0.2603999972343445},{"id":"https://openalex.org/C2777488183","wikidata":"https://www.wikidata.org/wiki/Q6900510","display_name":"Safety monitoring","level":2,"score":0.2565000057220459}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ccta53793.2025.11151283","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ccta53793.2025.11151283","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE Conference on Control Technology and Applications (CCTA)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":24,"referenced_works":["https://openalex.org/W2010973666","https://openalex.org/W2016617706","https://openalex.org/W2588802774","https://openalex.org/W2842089854","https://openalex.org/W2921750014","https://openalex.org/W2982715371","https://openalex.org/W3096430545","https://openalex.org/W3133087044","https://openalex.org/W3142005321","https://openalex.org/W4285297047","https://openalex.org/W4295308437","https://openalex.org/W4312368000","https://openalex.org/W4323868075","https://openalex.org/W4367604142","https://openalex.org/W4387123822","https://openalex.org/W4387790145","https://openalex.org/W4389215222","https://openalex.org/W4391020477","https://openalex.org/W4391022039","https://openalex.org/W4391741307","https://openalex.org/W4400934934","https://openalex.org/W4403093692","https://openalex.org/W4403818824","https://openalex.org/W4414117753"],"related_works":["https://openalex.org/W2066052364","https://openalex.org/W4243365217","https://openalex.org/W2224296908","https://openalex.org/W2023743128","https://openalex.org/W3109981693","https://openalex.org/W2381980429","https://openalex.org/W2384206113","https://openalex.org/W645983410","https://openalex.org/W2808346476","https://openalex.org/W2071108033"],"abstract_inverted_index":{"Nowadays,":[0],"many":[1],"control":[2,13,67],"systems":[3],"are":[4,15],"networked":[5],"and":[6,9,68,111],"embed":[7],"communication":[8],"computation":[10],"capabilities.":[11],"Such":[12],"architectures":[14],"prone":[16],"to":[17,29,32,103],"cyber":[18],"attacks":[19],"on":[20,83],"the":[21,34,84,89,123,126,143],"cyberinfrastructure.":[22],"Consequently,":[23],"there":[24],"is":[25,52],"an":[26,114,117],"impellent":[27],"need":[28],"develop":[30],"solutions":[31],"preserve":[33],"plant's":[35],"safety":[36,48,73,77,112,144],"against":[37],"potential":[38],"attacks.":[39,151],"To":[40],"ensure":[41],"safety,":[42],"this":[43],"paper":[44],"introduces":[45],"a":[46,130],"modular":[47],"filter":[49,78,145],"approach":[50],"that":[51,142],"effective":[53],"for":[54],"various":[55],"cyber-attack":[56],"types.":[57],"This":[58],"solution":[59],"can":[60,94],"be":[61,95],"implemented":[62,96],"in":[63,97],"combination":[64],"with":[65,99],"existing":[66],"detection":[69],"algorithms,":[70],"effectively":[71,147],"separating":[72],"from":[74],"performance.":[75],"The":[76,138],"does":[79],"not":[80],"require":[81],"information":[82],"received":[85],"command's":[86],"reliability":[87],"or":[88],"anomaly":[90],"detector's":[91],"feature.":[92],"It":[93],"conjunction":[98],"high-performance,":[100],"resilient":[101],"controllers":[102],"achieve":[104],"both":[105],"high":[106],"performance":[107],"during":[108,113,148],"normal":[109],"operation":[110],"attack.":[115],"As":[116],"illustrative":[118],"example,":[119],"we":[120],"have":[121],"shown":[122],"effectiveness":[124],"of":[125],"proposed":[127],"design":[128],"considering":[129],"multi-agent":[131],"formation":[132],"task":[133],"involving":[134],"20":[135],"mobile":[136],"robots.":[137],"simulation":[139],"results":[140],"testify":[141],"operates":[146],"undetectable,":[149],"intelligent":[150]},"counts_by_year":[{"year":2025,"cited_by_count":1}],"updated_date":"2026-06-25T08:15:23.626066","created_date":"2025-10-10T00:00:00"}
