{"id":"https://openalex.org/W2334342766","doi":"https://doi.org/10.1109/ccst.2014.6986996","title":"Security challenges in building automation and SCADA","display_name":"Security challenges in building automation and SCADA","publication_year":2014,"publication_date":"2014-10-01","ids":{"openalex":"https://openalex.org/W2334342766","doi":"https://doi.org/10.1109/ccst.2014.6986996","mag":"2334342766"},"language":"en","primary_location":{"id":"doi:10.1109/ccst.2014.6986996","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ccst.2014.6986996","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 International Carnahan Conference on Security Technology (ICCST)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5077623551","display_name":"Alessio Antonini","orcid":"https://orcid.org/0000-0002-1363-8607"},"institutions":[{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["IT"],"is_corresponding":true,"raw_author_name":"Alessio Antonini","raw_affiliation_strings":["Department of Electronics, Politecnico di Milano, Milan, Italy"],"affiliations":[{"raw_affiliation_string":"Department of Electronics, Politecnico di Milano, Milan, Italy","institution_ids":["https://openalex.org/I93860229"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5061596244","display_name":"Alessandro Barenghi","orcid":"https://orcid.org/0000-0003-0840-6358"},"institutions":[{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Alessandro Barenghi","raw_affiliation_strings":["Department of Electronics, Politecnico di Milano, Milan, Italy"],"affiliations":[{"raw_affiliation_string":"Department of Electronics, Politecnico di Milano, Milan, Italy","institution_ids":["https://openalex.org/I93860229"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5059940813","display_name":"Gerardo Pelosi","orcid":"https://orcid.org/0000-0002-3812-5429"},"institutions":[{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Gerardo Pelosi","raw_affiliation_strings":["Department of Electronics, Politecnico di Milano, Milan, Italy"],"affiliations":[{"raw_affiliation_string":"Department of Electronics, Politecnico di Milano, Milan, Italy","institution_ids":["https://openalex.org/I93860229"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5092023709","display_name":"Saman Zonouz","orcid":"https://orcid.org/0009-0006-7302-0178"},"institutions":[{"id":"https://openalex.org/I145608581","display_name":"University of Miami","ror":"https://ror.org/02dgjyy92","country_code":"US","type":"education","lineage":["https://openalex.org/I145608581"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Saman Zonouz","raw_affiliation_strings":["Electrical and Computer, University of Miami, Miami, FL, USA"],"affiliations":[{"raw_affiliation_string":"Electrical and Computer, University of Miami, Miami, FL, USA","institution_ids":["https://openalex.org/I145608581"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5077623551"],"corresponding_institution_ids":["https://openalex.org/I93860229"],"apc_list":null,"apc_paid":null,"fwci":2.4346,"has_fulltext":false,"cited_by_count":16,"citation_normalized_percentile":{"value":0.90328788,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12122","display_name":"Physical Unclonable Functions (PUFs) and Hardware Security","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11424","display_name":"Security and Verification in Computing","score":0.9959999918937683,"subfield":{"id":"https://openalex.org/subfields/1702","display_name":"Artificial Intelligence"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/scada","display_name":"SCADA","score":0.8464653491973877},{"id":"https://openalex.org/keywords/computer-security","display_name":"Computer security","score":0.7353854179382324},{"id":"https://openalex.org/keywords/cyber-physical-system","display_name":"Cyber-physical system","score":0.6812601685523987},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6409124135971069},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.5778622627258301},{"id":"https://openalex.org/keywords/building-automation","display_name":"Building automation","score":0.5384104251861572},{"id":"https://openalex.org/keywords/authentication","display_name":"Authentication (law)","score":0.5280126929283142},{"id":"https://openalex.org/keywords/automation","display_name":"Automation","score":0.4983234405517578},{"id":"https://openalex.org/keywords/industrial-control-system","display_name":"Industrial control system","score":0.45512861013412476},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.4179582893848419},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.32052358984947205},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.22337275743484497},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.1321350336074829}],"concepts":[{"id":"https://openalex.org/C113863187","wikidata":"https://www.wikidata.org/wiki/Q17498","display_name":"SCADA","level":2,"score":0.8464653491973877},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.7353854179382324},{"id":"https://openalex.org/C179768478","wikidata":"https://www.wikidata.org/wiki/Q1120057","display_name":"Cyber-physical system","level":2,"score":0.6812601685523987},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6409124135971069},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.5778622627258301},{"id":"https://openalex.org/C83931994","wikidata":"https://www.wikidata.org/wiki/Q1149653","display_name":"Building automation","level":2,"score":0.5384104251861572},{"id":"https://openalex.org/C148417208","wikidata":"https://www.wikidata.org/wiki/Q4825882","display_name":"Authentication (law)","level":2,"score":0.5280126929283142},{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.4983234405517578},{"id":"https://openalex.org/C40071531","wikidata":"https://www.wikidata.org/wiki/Q2513962","display_name":"Industrial control system","level":3,"score":0.45512861013412476},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.4179582893848419},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.32052358984947205},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.22337275743484497},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.1321350336074829},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/ccst.2014.6986996","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ccst.2014.6986996","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 International Carnahan Conference on Security Technology (ICCST)","raw_type":"proceedings-article"},{"id":"pmh:oai:alma.01RUT_INST:11663527910004646","is_oa":false,"landing_page_url":"https://scholarship.libraries.rutgers.edu/esploro/outputs/conferenceProceeding/Security-challenges-in-building-automation-and/991031654595704646","pdf_url":null,"source":{"id":"https://openalex.org/S4210197018","display_name":"View","issn_l":"2688-268X","issn":["2688-268X","2688-3988"],"is_oa":false,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310320595","host_organization_name":"Wiley","host_organization_lineage":["https://openalex.org/P4310320595"],"host_organization_lineage_names":["Wiley"],"type":"journal"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Conference Proceedings"},{"id":"pmh:oai:re.public.polimi.it:11311/860942","is_oa":false,"landing_page_url":"http://hdl.handle.net/11311/860942","pdf_url":null,"source":{"id":"https://openalex.org/S4306400312","display_name":"Virtual Community of Pathological Anatomy (University of Castilla La Mancha)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I79189158","host_organization_name":"University of Castilla-La Mancha","host_organization_lineage":["https://openalex.org/I79189158"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8899999856948853,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":23,"referenced_works":["https://openalex.org/W13926338","https://openalex.org/W62332037","https://openalex.org/W79658127","https://openalex.org/W205184685","https://openalex.org/W1507875035","https://openalex.org/W1579488430","https://openalex.org/W2002578057","https://openalex.org/W2041229218","https://openalex.org/W2051314193","https://openalex.org/W2052303336","https://openalex.org/W2056451850","https://openalex.org/W2068693276","https://openalex.org/W2077699686","https://openalex.org/W2116207513","https://openalex.org/W2123251735","https://openalex.org/W2126598527","https://openalex.org/W2160491639","https://openalex.org/W2541195669","https://openalex.org/W2555431798","https://openalex.org/W4248166939","https://openalex.org/W6602545441","https://openalex.org/W6630302480","https://openalex.org/W6683647664"],"related_works":["https://openalex.org/W2516092834","https://openalex.org/W2309980522","https://openalex.org/W2187618570","https://openalex.org/W4252573951","https://openalex.org/W2902958991","https://openalex.org/W1980447405","https://openalex.org/W2801513872","https://openalex.org/W2961381604","https://openalex.org/W2615554433","https://openalex.org/W2804225172"],"abstract_inverted_index":{"Cyber-Physical":[0],"Systems":[1],"(CPSs)":[2],"are":[3],"systems":[4,80],"in":[5,23,35,65,106],"which":[6],"software":[7],"and":[8,12,31,38,49,100,111,116,151],"hardware":[9],"entities":[10],"monitor":[11],"manage":[13],"physical":[14,58,156],"devices":[15],"using":[16],"communication":[17,51],"channels.":[18],"They":[19],"have":[20],"become":[21],"ubiquitous":[22],"many":[24],"domains":[25],"including":[26],"health":[27],"monitoring,":[28],"smart":[29,36,39],"vehicles":[30],"energy":[32],"efficiency":[33],"as":[34,81,83],"buildings":[37],"grid":[40],"operations.":[41],"The":[42,136],"introduction":[43],"of":[44,63,74,78,102,138],"a":[45,50],"digital":[46],"control":[47,120,127],"system":[48,134,157],"channel,":[52],"to":[53,87,97,114,143],"exchange":[54],"data":[55,105],"with":[56],"the":[57,61,66,72,75,84,103,119,124,139,154],"system,":[59],"increases":[60],"chance":[62],"vulnerabilities":[64,77],"overall":[67],"system.":[68],"This":[69],"paper":[70],"presents":[71],"state-of-the-art":[73],"security":[76],"such":[79,89],"well":[82],"possible":[85],"methods":[86],"mitigate/reduce":[88],"threats.":[90],"We":[91],"will":[92],"describe":[93],"recent":[94],"promising":[95],"solutions":[96],"guarantee":[98],"confidentiality":[99],"authentication":[101],"transported":[104],"building":[107],"automation":[108],"network":[109,128],"domains,":[110],"present":[112],"ideas":[113],"analyze":[115],"formally":[117],"verify":[118],"commands":[121,150],"issued":[122],"by":[123],"(possibly":[125],"compromised)":[126],"computers":[129],"for":[130],"execution":[131],"on":[132],"SCADA":[133],"actuators.":[135],"purpose":[137],"latter":[140],"approach":[141],"is":[142],"prevent":[144],"malicious":[145,149],"parties":[146],"from":[147],"injecting":[148],"potentially":[152],"driving":[153],"underlying":[155],"into":[158],"an":[159],"unsafe":[160],"state.":[161]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":3},{"year":2017,"cited_by_count":4},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
