{"id":"https://openalex.org/W2154826645","doi":"https://doi.org/10.1109/ccnc.2011.5766545","title":"Analysis of wireless sensor sleep mechanism with group arrival queuing model","display_name":"Analysis of wireless sensor sleep mechanism with group arrival queuing model","publication_year":2011,"publication_date":"2011-01-01","ids":{"openalex":"https://openalex.org/W2154826645","doi":"https://doi.org/10.1109/ccnc.2011.5766545","mag":"2154826645"},"language":"en","primary_location":{"id":"doi:10.1109/ccnc.2011.5766545","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ccnc.2011.5766545","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 IEEE Consumer Communications and Networking Conference (CCNC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100767141","display_name":"Liang Zheng","orcid":"https://orcid.org/0000-0002-3459-1844"},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Zheng Liang","raw_affiliation_strings":["Research and Innovation Center, Alcatel Lucent Shanghai Bell Company Limited, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"Research and Innovation Center, Alcatel Lucent Shanghai Bell Company Limited, Shanghai, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100514217","display_name":"Songwei Ma","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Songwei Ma","raw_affiliation_strings":["Research and Innovation Center, Alcatel Lucent Shanghai Bell Company Limited, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"Research and Innovation Center, Alcatel Lucent Shanghai Bell Company Limited, Shanghai, China","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101914314","display_name":"Qingshan Zhang","orcid":"https://orcid.org/0000-0003-1217-8925"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Qingshan Zhang","raw_affiliation_strings":["Research and Innovation Center, Alcatel Lucent Shanghai Bell Company Limited, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"Research and Innovation Center, Alcatel Lucent Shanghai Bell Company Limited, Shanghai, China","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5100767141"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.3501,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.65725013,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"570","last_page":"574"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10080","display_name":"Energy Efficient Wireless Sensor Networks","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10080","display_name":"Energy Efficient Wireless Sensor Networks","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10246","display_name":"Mobile Ad Hoc Networks","score":0.9965000152587891,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11896","display_name":"Opportunistic and Delay-Tolerant Networks","score":0.9957000017166138,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/queueing-theory","display_name":"Queueing theory","score":0.7620225548744202},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7451398372650146},{"id":"https://openalex.org/keywords/wireless-sensor-network","display_name":"Wireless sensor network","score":0.7402506470680237},{"id":"https://openalex.org/keywords/network-packet","display_name":"Network packet","score":0.606322705745697},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.5684247016906738},{"id":"https://openalex.org/keywords/queue","display_name":"Queue","score":0.5461439490318298},{"id":"https://openalex.org/keywords/node","display_name":"Node (physics)","score":0.5285189151763916},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.5176535248756409},{"id":"https://openalex.org/keywords/sleep","display_name":"Sleep (system call)","score":0.5163708925247192},{"id":"https://openalex.org/keywords/duty-cycle","display_name":"Duty cycle","score":0.504217267036438},{"id":"https://openalex.org/keywords/queue-management-system","display_name":"Queue management system","score":0.4960049092769623},{"id":"https://openalex.org/keywords/queuing-delay","display_name":"Queuing delay","score":0.4446125626564026},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.12380075454711914}],"concepts":[{"id":"https://openalex.org/C22684755","wikidata":"https://www.wikidata.org/wiki/Q847526","display_name":"Queueing theory","level":2,"score":0.7620225548744202},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7451398372650146},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.7402506470680237},{"id":"https://openalex.org/C158379750","wikidata":"https://www.wikidata.org/wiki/Q214111","display_name":"Network packet","level":2,"score":0.606322705745697},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.5684247016906738},{"id":"https://openalex.org/C160403385","wikidata":"https://www.wikidata.org/wiki/Q220543","display_name":"Queue","level":2,"score":0.5461439490318298},{"id":"https://openalex.org/C62611344","wikidata":"https://www.wikidata.org/wiki/Q1062658","display_name":"Node (physics)","level":2,"score":0.5285189151763916},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.5176535248756409},{"id":"https://openalex.org/C2775841894","wikidata":"https://www.wikidata.org/wiki/Q4683692","display_name":"Sleep (system call)","level":2,"score":0.5163708925247192},{"id":"https://openalex.org/C199822604","wikidata":"https://www.wikidata.org/wiki/Q557120","display_name":"Duty cycle","level":3,"score":0.504217267036438},{"id":"https://openalex.org/C128220111","wikidata":"https://www.wikidata.org/wiki/Q4531011","display_name":"Queue management system","level":3,"score":0.4960049092769623},{"id":"https://openalex.org/C196095461","wikidata":"https://www.wikidata.org/wiki/Q576842","display_name":"Queuing delay","level":3,"score":0.4446125626564026},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.12380075454711914},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ccnc.2011.5766545","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ccnc.2011.5766545","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 IEEE Consumer Communications and Networking Conference (CCNC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W1574057269","https://openalex.org/W2034548879","https://openalex.org/W2097149028","https://openalex.org/W2101386003","https://openalex.org/W2113443014","https://openalex.org/W2125597929","https://openalex.org/W2149028619","https://openalex.org/W2159013099","https://openalex.org/W2164045163","https://openalex.org/W2168452204"],"related_works":["https://openalex.org/W2368961776","https://openalex.org/W1535772705","https://openalex.org/W2361230975","https://openalex.org/W2184312385","https://openalex.org/W2622283040","https://openalex.org/W2509267828","https://openalex.org/W1983551639","https://openalex.org/W2783882805","https://openalex.org/W2581865514","https://openalex.org/W2172193389"],"abstract_inverted_index":{"This":[0],"paper":[1],"develops":[2],"an":[3,120],"analytic":[4],"model":[5,106],"for":[6,60,88],"wireless":[7],"sensor":[8,20,38],"network":[9],"node":[10,21,39],"that":[11],"adopts":[12],"sleep":[13,22,49,114,125],"mechanism.":[14],"Different":[15],"from":[16],"previous":[17],"works,":[18],"herein":[19],"period":[23,50,126],"is":[24,42,51,131],"modeled":[25],"as":[26],"arrival":[27],"of":[28,66,73],"group":[29],"packet":[30,93],"rather":[31],"than":[32],"server":[33],"vacation.":[34],"In":[35],"addition,":[36],"how":[37],"queuing":[40,68,129],"dynamics":[41,115],"effected":[43],"by":[44],"the":[45,55,104,122],"packets":[46],"generated":[47],"during":[48],"particularly":[52],"investigated.":[53],"Using":[54],"presented":[56],"model,":[57],"analytical":[58],"results":[59,87],"duty":[61],"cycle,":[62],"distribution":[63,70],"and":[64,71,76,90,98,116,128],"mean":[65,72],"total":[67],"delay,":[69],"queue":[74],"length,":[75],"other":[77],"system":[78,117],"performance":[79],"measures":[80],"can":[81],"be":[82],"figured":[83],"out.":[84],"Specifically,":[85],"calculation":[86],"negative-exponentially":[89],"mixed-Erlang":[91],"distributed":[92],"service":[94],"time":[95],"are":[96],"obtained":[97],"compared":[99],"with":[100],"each":[101],"other.":[102],"Moreover,":[103],"proposed":[105],"enables":[107],"us":[108],"to":[109],"study":[110],"various":[111],"tradeoffs":[112],"between":[113,124],"performance.":[118],"As":[119],"example":[121],"tradeoff":[123],"duration":[127],"delay":[130],"illustrated":[132],"in":[133],"this":[134],"paper.":[135]},"counts_by_year":[{"year":2015,"cited_by_count":2},{"year":2013,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
